1,370 research outputs found

    Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring

    Get PDF
    Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scannerbeam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options. based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadro

    Two-dimensional tunneling in a SQUID

    Full text link
    Traditionally quantum tunneling in a static SQUID is studied on the basis of a classical trajectory in imaginary time under a two-dimensional potential barrier. The trajectory connects a potential well and an outer region crossing their borders in perpendicular directions. In contrast to that main-path mechanism, a wide set of trajectories with components tangent to the border of the well can constitute an alternative mechanism of multi-path tunneling. The phenomenon is essentially non-one-dimensional. Continuously distributed paths under the barrier result in enhancement of tunneling probability. A type of tunneling mechanism (main-path or multi-path) depends on character of a state in the potential well prior to tunneling.Comment: 9 pages, 8 figure

    Desarrollo y empleo de juegos educativos on-line destinados al auto-entrenamiento y auto-evaluación

    Get PDF
    La implantación del EEES, está originando cambios en el modelo docente, cada vez más orientado al trabajo autónomo del alumno. Los contenidos electrónicos que apoyan el proceso de aprendizaje también deben, por tanto, orientarse a facilitar el aprendizaje autónomo, como por ejemplo los procesos de autoevaluación y auto-entrenamiento por parte del estudiante. Por ello, parece adecuado desarrollar contenidos electrónicos que motiven y a la vez entretengan de forma amena al alumnado durante su aprendizaje autónomo. En esta contribución, proponemos una serie de juegos educativos electrónicos como herramienta que haga de la auto-evaluación y del autoentrenamiento un proceso ameno y entretenido.Peer Reviewe

    A Light Calibration System for the ProtoDUNE-DP Detector

    Full text link
    A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino Platform at CERN. The PDS is based on 36 8-inch photomultiplier tubes (PMTs) and will allow triggering on cosmic rays. The system serves as prototype for the PDS of the final DUNE DP far detector in which the PDS also has the function to allow the 3D event reconstruction on non-beam physics. For this purpose an equalized PMT response is desirable to allow using the same threshold definition for all PMT groups, simplifying the determination of the trigger efficiency. The light calibration system described in this paper is developed to provide this and to monitor the PMT performance in-situ.Comment: 15 pages, 5 figure

    Computer Animation to teach interpolation

    Get PDF
    While mathematics courses are a basic topic in engineering studies, they are often considered as a dif- cult subject by students. In this work we present a learning experience based on computer animation and using the perspective of mathematical modelling. Our goal is to provide the students with a context that motivates the study of function interpolation. We present a problem statement that is intended to be solved by means of the Modeling Cycle. The development of the activity and the strategies identi ed during the process are presented and discussed
    corecore