643 research outputs found

    Caudal cervical vertebral morphological variation is not associated with clinical signs in Warmblood horses

    Get PDF
    Background Variation in equine caudal cervical spine morphology at C6 and C7 has high prevalence in Warmblood horses and is suspected to be associated with pain in a large mixed-breed group of horses. At present no data exist on the relationship between radiographic phenotype and clinical presentation in Warmblood horses in a case-control study. Objectives To establish the frequency of radiographically visible morphologic variation in a large group of Warmblood horses with clinical signs and compare this with a group without clinical signs. We hypothesised that occurrence of morphologic variation in the case group would not differ from the control group, indicating there is no association between clinical signs and morphologic variation. Study design Retrospective case-control. Methods Radiographic presence or absence of morphologic variation of cervical vertebrae C6 and C7 was recorded in case (n = 245) and control horses (n = 132). Case and control groups were compared by univariable Pearson's Chi-square and multivariable logistic regression for measurement variables age, sex, breed, degenerative joint disease and morphologic variation at C6 and C7. Odds ratio and confidence intervals were obtained. A P <= 0.05 was considered statistically significant. Results Morphologic variation at C6 and C7 (n = 108/377 = 28.6%; Cases 58/245 = 23.7%; Control 50/132 = 38%) was less frequent in horses with clinical signs in univariable testing (OR 0.48, 95% CI 0.3-0.8, P = 0.001). Age, sex, breed and degenerative joint disease were not retained in the final multivariable logistic regression step whereas morphologic variation remained significantly less present in horses with clinical signs. Main limitations Possible demographic differences between equine clinics. Conclusions Morphologic variation in the caudal cervical spine was detected more frequently in horses without clinical signs. Therefore, radiographic presence of such variation does not necessarily implicate the presence of clinical signs

    Increased incidence of kidney diseases in general practice after a nationwide albuminuria self-test program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To study the influence of a nationwide albuminuria self-test program on the number of GP contacts for urinary complaints and/or kidney diseases and the number of newly diagnosed patients with kidney diseases by the GP.</p> <p>Methods</p> <p>Data were used from the Netherlands Information Network of General Practice (LINH), including a representative sample of general practices with a dynamic population of approximately 300.000 listed patients. Morbidity data were retrieved from electronic medical records, kept in a representative sample of general practices. The incidence of kidney diseases and urinary complaints before and after the albuminuria self-test program was compared with logistic regression analyses.</p> <p>Results</p> <p>Data were used from 139 general practices, including 444,220 registered patients. The number of GP consultations for kidney diseases and urinary complaints was increased in the year after the albuminuria self-test program and particularly shortly after the start of the program. Compared with the period before the self-test program, more patients have been diagnosed by the GP with symptoms/complaints of kidney disease and urinary diseases (OR = 1.7 (CI 1.4 - 2.0) and OR = 2.1 (CI 1.9 - 2.3), respectively). The odds on an abnormal urine-test in the period after the self-test program was three times higher than the year before (OR = 3.0 (CI 2.4 - 3.6)). The effect of the self-test program on newly diagnosed patients with an abnormal urine test was modified by both the presence of the risk factors hypertension and diabetes mellitus. For this diagnosis the highest OR was found in patients without both conditions (OR = 4.2 (CI 3.3 - 5.4)).</p> <p>Conclusions</p> <p>A nationwide albuminuria self-test program resulted in an increasing number of newly diagnosed kidney complaints and diseases the year after the program. The highest risks were found in patients without risk factors for kidney diseases.</p

    Automatic detection of break-over phase onset in horses using hoof-mounted inertial measurement unit sensors

    Get PDF
    A prolonged break-over phase might be an indication of a variety of musculoskeletal disorders and can be measured with optical motion capture (OMC) systems, inertial measurement units (IMUs) and force plates. The aim of this study was to present two algorithms for automatic detection of the break-over phase onset from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. The performance of these algorithms was evaluated by internal validation with an OMC system and a force plate separately. Seven Warmblood horses were equipped with two wireless IMUs which were attached to the lateral wall of the right front (RF) and hind (RH) hooves. Horses were walked and trotted over a force plate for internal validation while simultaneously the 3D position of three reflective markers, attached to lateral heel, lateral toe and lateral coronet of each hoof, were measured by six infrared cameras of an OMC system. The performance of the algorithms was evaluated by linear mixed model analysis. The acceleration algorithm was the most accurate with an accuracy between -9 and 23 ms and a precision around 24 ms (against OMC system), and an accuracy between -37 and 20 ms and a precision around 29 ms (against force plate), depending on gait and hoof. This algorithm seems promising for quantification of the break-over phase onset although the applicability for clinical purposes, such as lameness detection and evaluation of trimming and shoeing techniques, should be investigated more in-depth

    Automatic hoof-on and -off detection in horses using hoof-mounted inertial measurement unit sensors

    Get PDF
    For gait classification, hoof-on and hoof-off events are fundamental locomotion characteristics of interest. These events can be measured with inertial measurement units (IMUs) which measure the acceleration and angular velocity in three directions. The aim of this study was to present two algorithms for automatic detection of hoof-events from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. Seven Warmblood horses were equipped with two wireless IMUs, which were attached to the lateral wall of the right front (RF) and hind (RH) hooves. Horses were walked and trotted on a lead over a force plate for internal validation. The agreement between the algorithms for the acceleration and angular velocity signals with the force plate was evaluated by Bland Altman analysis and linear mixed model analysis. These analyses were performed for both hoof-on and hoof-off detection and for both algorithms separately. For the hoof-on detection, the angular velocity algorithm was the most accurate with an accuracy between 2.39 and 12.22 ms and a precision of around 13.80 ms, depending on gait and hoof. For hoof-off detection, the acceleration algorithm was the most accurate with an accuracy of 3.20 ms and precision of 6.39 ms, independent of gait and hoof. These algorithms look highly promising for gait classification purposes although the applicability of these algorithms should be investigated under different circumstances, such as different surfaces and different hoof trimming conditions

    Variation in detected adverse events using trigger tools: A systematic review and meta-analysis

    Get PDF
    Adverse event (AE) detection is a major patient safety priority. However, despite extensive research on AEs, reported incidence rates vary widely.; This study aimed: (1) to synthesize available evidence on AE incidence in acute care inpatient settings using Trigger Tool methodology; and (2) to explore whether study characteristics and study quality explain variations in reported AE incidence.; Systematic review and meta-analysis.; To identify relevant studies, we queried PubMed, EMBASE, CINAHL, Cochrane Library and three journals in the patient safety field (last update search 25.05.2022). Eligible publications fulfilled the following criteria: adult inpatient samples; acute care hospital settings; Trigger Tool methodology; focus on specialty of internal medicine, surgery or oncology; published in English, French, German, Italian or Spanish. Systematic reviews and studies addressing adverse drug events or exclusively deceased patients were excluded. Risk of bias was assessed using an adapted version of the Quality Assessment Tool for Diagnostic Accuracy Studies 2. Our main outcome of interest was AEs per 100 admissions. We assessed nine study characteristics plus study quality as potential sources of variation using random regression models. We received no funding and did not register this review.; Screening 6,685 publications yielded 54 eligible studies covering 194,470 admissions. The cumulative AE incidence was 30.0 per 100 admissions (95% CI 23.9-37.5; I2 = 99.7%) and between study heterogeneity was high with a prediction interval of 5.4-164.7. Overall studies' risk of bias and applicability-related concerns were rated as low. Eight out of nine methodological study characteristics did explain some variation of reported AE rates, such as patient age and type of hospital. Also, study quality did explain variation.; Estimates of AE studies using trigger tool methodology vary while explaining variation is seriously hampered by the low standards of reporting such as the timeframe of AE detection. Specific reporting guidelines for studies using retrospective medical record review methodology are necessary to strengthen the current evidence base and to help explain between study variation
    • …
    corecore