58 research outputs found

    HRS white paper on clinical utilization of digital health technology.

    Get PDF
    This collaborative statement from the Digital Health Committee of the Heart Rhythm Society provides everyday clinical scenarios in which wearables may be utilized by patients for cardiovascular health and arrhythmia management. We describe herein the spectrum of wearables that are commercially available for patients, and their benefits, shortcomings and areas for technological improvement. Although wearables for rhythm diagnosis and management have not been examined in large randomized clinical trials, undoubtedly the usage of wearables has quickly escalated in clinical practice. This document is the first of a planned series in which we will update information on wearables as they are revised and released to consumers

    Left ventricular volume: an optimal parameter to detect systolic dysfunction on prospectively triggered 64-multidetector row computed tomography: another step towards reducing radiation exposure

    Get PDF
    In this study, we define the correlation between LV volumes (both LV end-diastolic volume [LVEDV] and LV end-systolic volume [LVESV]) and ejection fraction (EF) on 64 slice multi-detector computed tomography (MDCT). We also determine the accuracy of all the LV volume (LVV) parameters to detect LV systolic dysfunction (LVSD) and investigate the feasibility of using LVV as a surrogate of LVSD on prospectively gated imaging to prevent the radiation exposure of retrospective imaging. 568 patients undergoing 64-detector MDCT were divided into 2 groups: Group 1—subjects without any heart disease and LVEF ≥ 50%; and Group 2—patients with coronary artery disease and LVEF < 50% (defined as LVSD). The LVV (LV cavity only) and Total LV volume (cavity + LV mass) at end-systole and end-diastole (LVESV, Total LVESV, LVEDV and Total LVEDV) were measured. The upper limit values (mean + 2 SD) of all LVV parameters in Group 1 were used as the reference criterion to diagnose LVSD in Group 2. An exponential correlation was found between LVEF and all the LVV parameters. The specificity to detect LVSD in Group 2 was >90% and the sensitivity was 88.9, 83.3, 61.3 and 74.9% by using LVESV, Total LVESV, LVEDV and Total LVEDV, respectively. Systolic and diastolic LV volumes had a high correlation with LVEF and a high accuracy to detect LVSD. Thus, on prospectively triggered imaging, ventricular volumes can predict patients with reduced LVEF, and appropriate referrals can be made

    Association of Glomerular Filtration Rate with High-Sensitivity Cardiac Troponin T in a Community-Based Population Study in Beijing

    Get PDF
    BACKGROUND: Reduced renal function is an independent risk factor for cardiovascular disease mortality, and persistently elevated cardiac troponin T (cTnT) is frequently observed in patients with end-stage renal disease. In the general population the relationship between renal function and cTnT levels may not be clear because of the low sensitivity of the assay. In this study, we investigated the level of cTnT using a highly sensitive assay (hs-cTnT) and evaluated the association of estimated glomerular filtration rate (eGFR) with detectable hs-cTnT levels in a community-based population. METHODS: The serum hs-cTnT levels were measured in 1365 community dwelling population aged ≥45 years in Beijing, China. eGFR was determined by the Chinese modifying modification of diet in renal disease (C-MDRD) equation. RESULTS: With the highly sensitive assay, cTnT levels were detectable (≥3pg/mL) in 744 subjects (54.5%). The result showed that eGFR was associated with Log hs-cTnT (r = -0.14, P<0.001). After adjustment for the high predicted Framingham Coronary Heart Disease (CHD) risk (10-year risk >20%) and other prognostic indicators, moderate to severe reduced eGFR was independently associated with detectable hs-cTnT, whereas normal to mildly reduced eGFR was not independently associated with detectable hs-cTnT. In addition, after adjustment for other risk factors, the high predicted Framingham CHD risk was associated with detectable hs-cTnT in the subjects with different quartile levels of eGFR. CONCLUSION: The levels of hs-cTnT are detectable in a community-based Chinese population and low eGFR is associated with detectable hs-cTnT. Moreover, eGFR and high predicted Framingham CHD risk are associated with detectable hs-cTnT in subjects with moderate-to-severe reduced renal function

    A Functional Polymorphism in Renalase (Glu37Asp) Is Associated with Cardiac Hypertrophy, Dysfunction, and Ischemia: Data from the Heart and Soul Study

    Get PDF
    Renalase is a soluble enzyme that metabolizes circulating catecholamines. A common missense polymorphism in the flavin-adenine dinucleotide-binding domain of human renalase (Glu37Asp) has recently been described. The association of this polymorphism with cardiac structure, function, and ischemia has not previously been reported.We genotyped the rs2296545 single-nucleotide polymorphism (Glu37Asp) in 590 Caucasian individuals and performed resting and stress echocardiography. Logistic regression was used to examine the associations of the Glu37Asp polymorphism (C allele) with cardiac hypertrophy (LV mass>100 g/m2), systolic dysfunction (LVEF<50%), diastolic dysfunction, poor treadmill exercise capacity (METS<5) and inducible ischemia.Compared with the 406 participants who had GG or CG genotypes, the 184 participants with the CC genotype had increased odds of left ventricular hypertrophy (OR = 1.43; 95% CI 0.99-2.06), systolic dysfunction (OR = 1.72; 95% CI 1.01-2.94), diastolic dysfunction (OR = 1.75; 95% CI 1.05-2.93), poor exercise capacity (OR = 1.61; 95% CI 1.05-2.47), and inducible ischemia (OR = 1.49, 95% CI 0.99-2.24). The Glu37Asp (CC genotype) caused a 24-fold decrease in affinity for NADH and a 2.3-fold reduction in maximal renalase enzymatic activity.A functional missense polymorphism in renalase (Glu37Asp) is associated with cardiac hypertrophy, ventricular dysfunction, poor exercise capacity, and inducible ischemia in persons with stable coronary artery disease. Further studies investigating the therapeutic implications of this polymorphism should be considered

    Flavaglines Alleviate Doxorubicin Cardiotoxicity: Implication of Hsp27

    Get PDF
    Background: Despite its effectiveness in the treatment of various cancers, the use of doxorubicin is limited by a potentially fatal cardiomyopathy. Prevention of this cardiotoxicity remains a critical issue in clinical oncology. We hypothesized that flavaglines, a family of natural compounds that display potent neuroprotective effects, may also alleviate doxorubicininduced cardiotoxicity. Methodology/Principal Findings: Our in vitro data established that a pretreatment with flavaglines significantly increased viability of doxorubicin-injured H9c2 cardiomyocytes as demonstrated by annexin V, TUNEL and active caspase-3 assays. We demonstrated also that phosphorylation of the small heat shock protein Hsp27 is involved in the mechanism by which flavaglines display their cardioprotective effect. Furthermore, knocking-down Hsp27 in H9c2 cardiomyocytes completely reversed this cardioprotection. Administration of our lead compound (FL3) to mice attenuated cardiomyocyte apoptosis and cardiac fibrosis, as reflected by a 50 % decrease of mortality. Conclusions/Significance: These results suggest a prophylactic potential of flavaglines to prevent doxorubicin-induce

    Consumer-Led Screening for Atrial Fibrillation: Frontier Review of the AF-SCREEN International Collaboration.

    Get PDF
    The technological evolution and widespread availability of wearables and handheld ECG devices capable of screening for atrial fibrillation (AF), and their promotion directly to consumers, has focused attention of health care professionals and patient organizations on consumer-led AF screening. In this Frontiers review, members of the AF-SCREEN International Collaboration provide a critical appraisal of this rapidly evolving field to increase awareness of the complexities and uncertainties surrounding consumer-led AF screening. Although there are numerous commercially available devices directly marketed to consumers for AF monitoring and identification of unrecognized AF, health care professional-led randomized controlled studies using multiple ECG recordings or continuous ECG monitoring to detect AF have failed to demonstrate a significant reduction in stroke. Although it remains uncertain if consumer-led AF screening reduces stroke, it could increase early diagnosis of AF and facilitate an integrated approach, including appropriate anticoagulation, rate or rhythm management, and risk factor modification to reduce complications. Companies marketing AF screening devices should report the accuracy and performance of their products in high- and low-risk populations and avoid claims about clinical outcomes unless improvement is demonstrated in randomized clinical trials. Generally, the diagnostic yield of AF screening increases with the number, duration, and temporal dispersion of screening sessions, but the prognostic importance may be less than for AF detected by single-time point screening, which is largely permanent, persistent, or high-burden paroxysmal AF. Consumer-initiated ECG recordings suggesting possible AF always require confirmation by a health care professional experienced in ECG reading, whereas suspicion of AF on the basis of photoplethysmography must be confirmed with an ECG. Consumer-led AF screening is unlikely to be cost-effective for stroke prevention in the predominantly young, early adopters of this technology. Studies in older people at higher stroke risk are required to demonstrate both effectiveness and cost-effectiveness. The direct interaction between companies and consumers creates new regulatory gaps in relation to data privacy and the registration of consumer apps and devices. Although several barriers for optimal use of consumer-led screening exist, results of large, ongoing trials, powered to detect clinical outcomes, are required before health care professionals should support widespread adoption of consumer-led AF screening

    Effect of Chronic Kidney Diseases on Mortality among Digoxin Users Treated for Non-Valvular Atrial Fibrillation: A Nationwide Register-Based Retrospective Cohort Study.

    Get PDF
    PURPOSE: This study investigated the impact of chronic kidney disease on all-causes and cardiovascular mortality in patients with atrial fibrillation treated with digoxin. METHODS: All patients with non-valvular atrial fibrillation and/or atrial flutter as hospitalization diagnosis from January 1, 1997 to December 31, 2012 were identified in Danish nationwide administrative registries. Cox proportional hazard model was used to compare the adjusted risk of all-causes and cardiovascular mortality among patients with and without chronic kidney disease and among patients with different chronic kidney disease stages within 180 days and 2 years from the first digoxin prescription. RESULTS: We identified 37,981 patients receiving digoxin; 1884 patients had the diagnosis of chronic kidney disease. Cox regression analysis showed no statistically significant differences in all-causes (Hazard Ratio, HR 0.89; 95% confident interval, CI 0.78-1.03) and cardiovascular mortality (HR 0.88; 95%CI 0.74-1.05) among patients with and without chronic kidney disease within 180 days of follow-up period. No statistically significant differences was found using a 2 years follow-up period neither for all causes mortality (HR 0.90; 95%CI 0.79-1.03), nor for cardiovascular mortality (HR 0.87; 95%CI 0.74-1.02). No statistically significant differences was found comparing patients with and without estimated Glomerular Filtration Rate <30ml/min/1.73m2 and patients with different stages of chronic kidney disease, for all-causes and cardiovascular mortality within 180 days and 2 years from the first digoxin prescription. CONCLUSIONS: This study suggest no direct effect of chronic kidney disease and chronic kidney disease stages on all-causes and cardiovascular mortality within both 180 days and 2 years from the first digoxin prescription in patients treatment-naïve with digoxin for non-valvular atrial fibrillation
    corecore