670 research outputs found

    Expanding Access to Treatment for Hepatitis C in Resource-Limited Settings: Lessons From HIV/AIDS

    Get PDF
    This article summarizes key lessons from scaling up care and treatment for human immunodeficiency virus/AIDS during the last decade to support increased access to treatment and care for hepatitis C virus infection in resource-limited setting

    Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis

    Get PDF
    Supported by the Global Alliance for TB Drug Development with support from the Bill and Melinda Gates Foundation, the European and Developing Countries Clinical Trials Partnership (Grant IP.2007.32011.011), US Agency for International Development, UK Department for International Development, Directorate General for International Cooperation of the Netherlands, Irish Aid, Australia Department of Foreign Affairs and Trade, National Institutes of Health, AIDS Clinical Trials Group. The study was also supported by grants from the National Institute of Allergy and Infectious Diseases (NIAID) (UM1AI068634, UM1 AI068636, and UM1AI106701) and by NIAID grants to the University of KwaZulu Natal, South Africa, AIDS Clinical Trials Group (ACTG) site 31422 (1U01AI069469); to the Perinatal HIV Research Unit, Chris Hani Baragwanath Hospital, South Africa, ACTG site 12301 (1U01AI069453); and to the Durban International Clinical Trials Unit, South Africa, ACTG site 11201 (1U01AI069426). Bayer Healthcare for donated moxifloxacin and Sanofi donated rifampin.Background:  The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. Methods:  Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. Results:  Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24–41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318–535). Pre-treatment spot samples had a higher yield of positive Ziehl–Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P < 0.001). There were no differences in time to positivity in pre-treatment LJ culture, or in post-treatment MGIT or LJ cultures. Comparing EMS and spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan–Meier analyses in either EMS or spot samples. Conclusions:  Our data do not support the hypothesis that EMS samples are superior to spot sputum samples in a clinical trial of patients with smear positive pulmonary TB. Observed small differences in mycobacterial burden are of uncertain significance and EMS samples do not detect post-treatment positives any sooner than spot samples.Publisher PDFPeer reviewe

    Pretreatment chest x-ray severity and its relation to bacterial burden in smear positive pulmonary tuberculosis

    Get PDF
    Background Chest radiographs are used for diagnosis and severity assessment in tuberculosis (TB). The extent of disease as determined by smear grade and cavitation as a binary measure can predict 2-month smear results, but little has been done to determine whether radiological severity reflects the bacterial burden at diagnosis. Methods Pre-treatment chest x-rays from 1837 participants with smear-positive pulmonary TB enrolled into the REMoxTB trial (Gillespie et al., N Engl J Med 371:1577–87, 2014) were retrospectively reviewed. Two clinicians blinded to clinical details using the Ralph scoring system performed separate readings. An independent reader reviewed discrepant results for quality assessment and cavity presence. Cavitation presence was plotted against time to positivity (TTP) of sputum liquid cultures (MGIT 960). The Wilcoxon rank sum test was performed to calculate the difference in average TTP for these groups. The average lung field affected was compared to log 10 TTP by linear regression. Baseline markers of disease severity and patient characteristics were added in univariable regression analysis against radiological severity and a multivariable regression model was created to explore their relationship. Results For 1354 participants, the median TTP was 117 h (4.88 days), being 26 h longer (95% CI 16–30, p < 0.001) in patients without cavitation compared to those with cavitation. The median percentage of lung-field affected was 18.1% (IQR 11.3–28.8%). For every 10-fold increase in TTP, the area of lung field affected decreased by 11.4%. Multivariable models showed that serum albumin decreased significantly as the percentage of lung field area increased in both those with and without cavitation. In addition, BMI and logged TTP had a small but significant effect in those with cavitation and the number of severe TB symptoms in the non-cavitation group also had a small effect, whilst other factors found to be significant on univariable analysis lost this effect in the model. Conclusions The radiological severity of disease on chest x-ray prior to treatment in smear positive pulmonary TB patients is weakly associated with the bacterial burden. When compared against other variables at diagnosis, this effect is lost in those without cavitation. Radiological severity does reflect the overall disease severity in smear positive pulmonary TB, but we suggest that clinicians should be cautious in over-interpreting the significance of radiological disease extent at diagnosis

    Search for a Technicolor omega_T Particle in Events with a Photon and a b-quark Jet at CDF

    Full text link
    If the Technicolor omega_T particle exists, a likely decay mode is omega_T -> gamma pi_T, followed by pi_T -> bb-bar, yielding the signature gamma bb-bar. We have searched 85 pb^-1 of data collected by the CDF experiment at the Fermilab Tevatron for events with a photon and two jets, where one of the jets must contain a secondary vertex implying the presence of a b quark. We find no excess of events above standard model expectations. We express the result of an exclusion region in the M_omega_T - M_pi_T mass plane.Comment: 14 pages, 2 figures. Available from the CDF server (PS with figs): http://www-cdf.fnal.gov/physics/pub98/cdf4674_omega_t_prl_4.ps FERMILAB-PUB-98/321-

    Measurement of the B0 anti-B0 oscillation frequency using l- D*+ pairs and lepton flavor tags

    Full text link
    The oscillation frequency Delta-md of B0 anti-B0 mixing is measured using the partially reconstructed semileptonic decay anti-B0 -> l- nubar D*+ X. The data sample was collected with the CDF detector at the Fermilab Tevatron collider during 1992 - 1995 by triggering on the existence of two lepton candidates in an event, and corresponds to about 110 pb-1 of pbar p collisions at sqrt(s) = 1.8 TeV. We estimate the proper decay time of the anti-B0 meson from the measured decay length and reconstructed momentum of the l- D*+ system. The charge of the lepton in the final state identifies the flavor of the anti-B0 meson at its decay. The second lepton in the event is used to infer the flavor of the anti-B0 meson at production. We measure the oscillation frequency to be Delta-md = 0.516 +/- 0.099 +0.029 -0.035 ps-1, where the first uncertainty is statistical and the second is systematic.Comment: 30 pages, 7 figures. Submitted to Physical Review

    Observation of Hadronic W Decays in t-tbar Events with the Collider Detector at Fermilab

    Full text link
    We observe hadronic W decays in t-tbar -> W (-> l nu) + >= 4 jet events using a 109 pb-1 data sample of p-pbar collisions at sqrt{s} = 1.8 TeV collected with the Collider Detector at Fermilab (CDF). A peak in the dijet invariant mass distribution is obtained that is consistent with W decay and inconsistent with the background prediction by 3.3 standard deviations. From this peak we measure the W mass to be 77.2 +- 4.6 (stat+syst) GeV/c^2. This result demonstrates the presence of two W bosons in t-tbar candidates in the W (-> l nu) + >= 4 jet channel.Comment: 20 pages, 4 figures, submitted to PR

    Search for Chargino-Neutralino Associated Production at the Fermilab Tevatron Collider

    Full text link
    We have searched in ppˉp \bar{p} collisions at s\sqrt{s} = 1.8 TeV for events with three charged leptons and missing transverse energy. In the Minimal Supersymmetric Standard Model, we expect trilepton events from chargino-neutralino (\chione \chitwo) pair production, with subsequent decay into leptons. We observe no candidate e+ee±e^+e^-e^\pm, e+eμ±e^+e^-\mu^\pm, e±μ+μe^\pm\mu^+\mu^- or μ+μμ±\mu^+\mu^-\mu^\pm events in 106 pb1^{-1} integrated luminosity. We present limits on the sum of the branching ratios times cross section for the four channels: \sigma_{\chione\chitwo}\cdot BR(\chione\chitwo\to 3\ell+X) 81.5 \mgev\sp and M_\chitwo > 82.2 \mgev\sp for tanβ=2\tan\beta=2, μ=600\mu =-600~\mgev\sp and M_\squark= M_\gluino.Comment: 9 pages and 3 figure

    Measurement of the lepton charge asymmetry in W-boson decays produced in p-pbar collisions

    Full text link
    We describe a measurement of the charge asymmetry of leptons from W boson decays in the rapidity range 0 enu, munu events from 110+/-7 pb^{-1}of data collected by the CDF detector during 1992-95. The asymmetry data constrain the ratio of d and u quark momentum distributions in the proton over the x range of 0.006 to 0.34 at Q2 \approx M_W^2. The asymmetry predictions that use parton distribution functions obtained from previously published CDF data in the central rapidity region (0.0<|y_l|<1.1) do not agree with the new data in the large rapidity region (|y_l|>1.1).Comment: 13 pages, 3 tables, 1 figur

    Search for New Particles Decaying to top-antitop in proton-antiproton collisions at squareroot(s)=1.8 TeV

    Get PDF
    We use 106 \ipb of data collected with the Collider Detector at Fermilab to search for narrow-width, vector particles decaying to a top and an anti-top quark. Model independent upper limits on the cross section for narrow, vector resonances decaying to \ttbar are presented. At the 95% confidence level, we exclude the existence of a leptophobic \zpr boson in a model of topcolor-assisted technicolor with mass M_{\zpr} << 480 \gev for natural width Γ\Gamma = 0.012 M_{\zpr}, and M_{\zpr} << 780 \gev for Γ\Gamma = 0.04 M_{\zpr}.Comment: The CDF Collaboration, submitted to PRL 25-Feb-200
    corecore