191 research outputs found
Palpation Device for the Identification of Kidney and Bladder Cancer: A Pilot Study
PURPOSE: To determine the ability of a novel palpation device to differentiate between benign and malignant tissues of the kidney and bladder by measuring tissue elasticity.
MATERIALS AND METHODS: A novel palpation device was developed, mainly composed of a micromotor, a linear position sensor, a force transducer, and a hemisphere tip and cylindrical body probe. Motion calibration as well as performance validation was done. The tissue elasticity of both benign and malignant tissues of the kidney and bladder was measured using this device. A single investigator performed the ex-vivo palpation experiment in twelve kidneys and four bladder specimens. Malignant tissues were made available from partial nephrectomy specimens and radical cystectomy specimens. Palpations for benign renal parenchyma tissue were carried out on nephroureterectomy specimens while non-involved areas in the radical cystectomy specimens were used for benign bladder samples. Elastic modulus (Young's modulus) of tissues was estimated using the Hertz-Sneddon equation from the experimental results. These were then compared using a t-test for independent samples.
RESULTS: Renal cell carcinoma tissues appear to be softer than normal kidney tissues, whereas tissues from urothelial carcinoma of the bladder appear to be harder than normal bladder tissues. The results from renal cell carcinoma differed significantly from those of normal kidney tissues (p=0.002), as did urothelial carcinoma of the bladder from normal bladder tissues (p=0.003).
CONCLUSION: Our novel palpation device can potentially differentiate between malignant and benign kidney and bladder tissues. Further studies are necessary to verify our results and define its true clinical utility.ope
The effect of periodontitis on recipient outcomes after kidney transplantation
Background Recent several reports have demonstrated that periodontitis is prevalent and adversely affects the survival in patients with chronic kidney disease (CKD) or end-stage kidney disease. However, its impact on transplant outcomes remains uncertain. Methods This retrospective cohort study included 136 and 167 patients, respectively, who underwent living donor kidney transplantation (KT) at Seoul National University Hospital from July 2012 to August 2016 and Korea University Hospital from April 2008 to October 2018. We divided patients into three groups according to stages of periodontitis based on a new classification system. Results Patients with severe periodontitis were older, had a higher prevalence of diabetes, a higher body mass index and C-reactive protein level, a lower cardiac output, and were more likely to be smokers, indicating its association with chronic systemic inflammation. After KT, stage IV periodontitis was independently associated with a lower incidence of acute T cell-mediated rejection, suggesting the possible effect of periodontitis on immune function. However, 1-year and 3-year estimated glomerular filtration rates were not different. Among the KT recipients followed up more than 3 years, new-onset cardiovascular disease occurred in nine patients, and coronary artery disease occurred more frequently in patients with stage IV periodontitis. However, diabetes was the independent predictor of new-onset coronary artery disease in multivariate logistic regression analysis. Conclusion Our findings showed that periodontitis might be an important player in determining posttransplant outcomes in recipients. Further interventional trials to test whether treating periodontitis could modify transplant outcome are needed
Self-catalytic growth of elementary semiconductor nanowires with controlled morphology and crystallographic orientation
While the orientation-dependent properties of semiconductor nanowires have been theoretically predicted, their study has long been overlooked in many fields owing to the limits to controlling the crystallographic growth direction of nanowires (NWs). We present here the orientation-controlled growth of single-crystalline germanium (Ge) NWs using a self-catalytic low-pressure chemical vapor deposition process. By adjusting the growth temperature, the orientation of growth direction in GeNWs was selectively controlled to the ⟨110⟩, ⟨112⟩, or ⟨111⟩ directions on the same substrate. The NWs with different growth directions exhibit distinct morphological features, allowing control of the NW morphology from uniform NWs to nanoribbon structures. Significantly, the VLS-based self-catalytic growth of the ⟨111⟩ oriented GeNW suggests that NW growth is possible for single elementary materials even without an appropriate external catalyst. Furthermore, these findings could provide opportunities to investigate the orientation-dependent properties of semiconductor NWs
A Randomized, Double-Blind, Placebo-Controlled, Bridging Study to Evaluate the Efficacy and Safety of Vibegron in Treating Korean Patients With Overactive Bladder
Purpose Vibegron, a novel, potent β3 agonist, has been approved for clinical use in overactive bladder (OAB) treatment in Japan and the Unites States. We performed a bridging study to investigate the efficacy and safety of a daily 50-mg vibegron (code name JLP-2002) dose in Korean patients with OAB. Methods A multicenter, randomized, double-blind, placebo-controlled study was conducted from September 2020 to August 2021. Adult patients with OAB with a symptom duration of more than 6 months entered a 2-week placebo run-in phase. Eligibility was assessed at the end of this phase and selected patients entered a double-blind treatment phase after 1:1 randomization to either the placebo or vibegron (50 mg) group. The study drug was administered once daily for 12 weeks and follow-up visits were scheduled at weeks 4, 8, and 12. The primary endpoint was the change in mean daily micturition at the end of treatment. The secondary endpoints included changes in OAB symptoms (daily micturition, nocturia, urgency, urgency incontinence, and incontinence episodes, and mean voided volume per micturition) and safety. A constrained longitudinal data model was used for statistical analysis. Results Patients who took daily vibegron had significant improvements over the placebo group in both primary and secondary endpoints, except for daily nocturia episodes. The proportions of patients with normalized micturition and resolution of urgency incontinence and incontinence episodes were significantly higher in vibegron group than in the placebo. Vibegron also improved the patients’ quality of life with higher satisfaction rates. The incidence of adverse events in the vibegron and placebo groups was similar with no serious, unexpected adverse drug reactions. No abnormality in electrocardiographs was observed as well as no significant increase in postvoid residual volume. Conclusions Once daily vibegron (50 mg) for 12 weeks was effective, safe, and well-tolerated in Korean patients with OAB
ACT-PRESTO: Rapid and consistent tissue clearing and labeling method for 3-dimensional (3D) imaging
Understanding the structural organization of organs and organisms at the cellular level is a fundamental challenge in biology. This task has been approached by reconstructing three-dimensional structure from images taken from serially sectioned tissues, which is not only labor-intensive and time-consuming but also error-prone. Recent advances in tissue clearing techniques allow visualization of cellular structures and neural networks inside of unsectioned whole tissues or the entire body. However, currently available protocols require long process times. Here, we present the rapid and highly reproducible ACT-PRESTO (active clarity technique-pressure related efficient and stable transfer of macromolecules into organs) method that clears tissues or the whole body within 1 day while preserving tissue architecture and protein-based signals derived from endogenous fluorescent proteins. Moreover, ACT-PRESTO is compatible with conventional immunolabeling methods and expedites antibody penetration into thick specimens by applying pressure. The speed and consistency of this method will allow high-content mapping and analysis of normal and pathological features in intact organs and bodies.1
Efficacy of two different self-expanding nitinol stents for atherosclerotic femoropopliteal arterial disease (SENS-FP trial): study protocol for a randomized controlled trial
BACKGROUND: There have been few randomized control trials comparing the incidence of stent fracture and primary patency among different self-expanding nitinol stents to date. The SMART™ CONTROL stent (Cordis Corp, Miami Lakes, Florida, United States) has a peak-to-valley bridge and inline interconnection, whereas the COMPLETE™-SE stent (Medtronic Vascular, Santa Rosa, California, United States) crowns have been configured to minimize crown-to-crown interaction, increasing the stent's flexibility without compromising radial strength. Further, the 2011 ESC (European society of cardiology) guidelines recommend that dual antiplatelet therapy with aspirin and a thienopyridine such as clopidogrel should be administered for at least one month after infrainguinal bare metal stent implantation. Cilostazol has been reported to reduce intimal hyperplasia and subsequent repeat revascularization. To date, there has been no randomized study comparing the safety and efficacy of two different antiplatelet regimens, clopidogrel and cilostazol, following successful femoropopliteal stenting. METHODS/DESIGN: The primary purpose of our study is to examine the incidence of stent fracture and primary patency between two different major representative self-expanding nitinol stents (SMART™ CONTROL versus COMPLETE™-SE) in stenotic or occlusive femoropopliteal arterial lesion. The secondary purpose is to examine whether there is any difference in efficacy and safety between aspirin plus clopidogrel versus aspirin plus cilostazol for one month following stent implantation in femoropopliteal lesions. This is a prospective, randomized, multicenter trial to assess the efficacy of the COMPLETE™-SE versus SMART™ CONTROL stent for provisional stenting after balloon angioplasty in femoropopliteal arterial lesions. The study design is a 2x2 randomization design and a total of 346 patients will be enrolled. The primary endpoint of this study is the rate of binary restenosis in the treated segment at 12 months after intervention as determined by catheter angiography or duplex ultrasound. DISCUSSION: This trial will provide powerful insight into whether the design of the COMPLETE™-SE stent is more fracture-resistant or effective in preventing restenosis compared with the SMART™ CONTROL stent. Also, it will determine the efficacy and safety of aspirin plus clopidogrel versus aspirin plus cilostazol in patients undergoing stent implantation in femoropopliteal lesions. TRIAL REGISTRATION: Registered on 2 April 2012 with the National Institutes of Health Clinical Trials Registry (ClinicalTrials.gov identifier# NCT01570803)
Growth Inhibition and Apoptosis with H31 Metabolites from Marine Bacillus SW31 in Head and Neck Cancer Cells
ObjectivesTo determine whether a novel marine micro-organism with anticancer properties, H31, the metabolic product of Bacillus SW31, has anti-tumor effects on head and neck cancer, and potential for apoptotic-enhancing anti-cancer treatment of affected patients.MethodsThe cell viability and apoptosis assays were performed. Changes in the signal pathway related to apoptosis were investigated. Then, the therapeutic effects of H31 were explored in mouse xenograft model and drug toxicity of H31 was examined in zebrafish model.ResultsWe identified the anticancer activity of H31, a novel metabolic product of Bacillus SW31. Bacillus SW31, a new marine micro-organism, has 70% homology with Bacillus firmus and contains potent cytotoxic bioactivity in head and neck cancer cells using MTT assay. Combined with c-JUN, p53, cytochrome C, and caspase-3, H31 induced apoptosis of KB cells, a head and neck cancer cell line. In a separate in vivo model, tumor growth in C3H/HeJ syngeneic mice was suppressed by H31. In addition, in a zebrafish model used for toxicity testing, a considerable dose of H31 did not result in embryo or neurotoxicity.ConclusionGrowth inhibition and apoptosis were achieved both in vitro and in vivo in head and neck cancer cells after exposure to H31, a metabolite from the marine Bacillus species, without any significant toxicity effects even at considerable H31 dose concentrations
- …