264 research outputs found

    Comparison of Spectral Radiance Calibration Techniques Used for Backscatter Ultraviolet Satellite Instruments

    Get PDF
    Methods for determining the absolute radiometric calibration sensitivities of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration errors. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV (SSBUV), Total Ozone Mapping Spectrometer (TOMS), Ozone Mapping Instrument (OMI), and Global Ozone Monitoring Experiment 2 (GOME-2) using standardized procedures traceable to national standards. These sphere-based sensitivities agree to within three percent [k equals 2] relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary radiance calibration method for BUV instruments. The uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Centers Radiometric Calibration and Development Laboratory is shown to be 4 percent at 250nm [k equals 2] when using a single traceable calibration standard. Significant reduction in the uncertainty of nearly 1 percent is demonstrated when multiple calibration standards are used

    Geostationary Coastal Ecosystem Dynamics Imager (GEO CEDI) for the GEO Coastal and Air Pollution Events (GEO CAPE) Mission. Concept Presentation

    Get PDF
    This slide presentation reviews the concepts of the Geostationary Coastal Ecosystem Dynamics Imager (GEO CEDI) which will be used on the GEO Coastal and Air Pollution Events (GEO CAPE) Mission. The primary science requirements require scans of the U.S. Coastal waters 3 times per day during the daylight hours. Included in the overview are presentations about the systems, the optics, the detectors, the mechanical systems, the electromechanical systems, the electrical design, the flight software, the thermal systems, and the contamination prevention requirements

    Multiaperture planar waveguide spectrometer formed by arrayed Mach-Zehnder interferometers

    Get PDF
    Concept, theory and simulations of a new type of waveguide device, a multiaperture Fourier-transform planar waveguide spectrometer, are presented. The spectrometer is formed by an array of Mach-Zehnder interferometers generating a wavelength dependent spatial fringe pattern at the array output. The input light spectrum is calculated using a discrete Fourier transformation of the output spatial fringes. The multiaperture input significantly increases the optical throughput (Ă©tendue) compared to conventional single input spectrometers. Design rules for the arrayed spectrometer are deduced from performance specifications such as wavelength range and spectral resolution. A design example with spectral resolution 0.025 nm and range 2.5 nm is presented, where the optical throughput is increased by a factor of 200 compared to a single input device

    DISCOVER-AQ: An Overview and Initial Comparisons of NO2 with OMI Observations

    Get PDF
    The first deployment of the Earth Venture -1 DISCOVER-AQ (Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality) project was conducted during July 2011 in the Baltimore-Washington region. Two aircraft (a P-3B for in-situ sampling and a King Air for remote sensing) were used along with an extensive array of surface-based in-situ and remote sensing instrumentation. Fourteen flight days were accomplished by both aircraft and over 250 profiles of trace gases and aerosols were performed by the P-3B over surface air quality monitoring stations, which were specially outfitted with sunphotometers and Pandora UV/Vis spectrometers. The King Air flew with the High Spectral Resolution Lidar for aerosols and the ACAM UV/Vis spectrometer for trace gases. This suite of observations allows linkage of surface air quality with the vertical distributions of gases and aerosols, with remotely-sensed column amounts observed from the surface and from the King Air, and with satellite observations from Aura (OMI and TES), GOME-2, MODIS and GOES. The DISCOVER-AQ data will allow determination of under what conditions satellite retrievals are indicative of surface air quality, and they will be useful in planning new satellites. In addition to an overview of the project, a preliminary comparison of tropospheric column NO2 densities from the integration of in-situ P-3B observations, from the Pandoras and ACAM, and from the new Goddard OMI NO2 algorithm will be presented

    First Top-Down Estimates of Anthropogenic NO_x Emissions Using High-Resolution Airborne Remote Sensing Observations

    Get PDF
    A number of satellite‐based instruments have become an essential part of monitoring emissions. Despite sound theoretical inversion techniques, the insufficient samples and the footprint size of current observations have introduced an obstacle to narrow the inversion window for regional models. These key limitations can be partially resolved by a set of modest high‐quality measurements from airborne remote sensing. This study illustrates the feasibility of nitrogen dioxide (NO_2) columns from the Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) to constrain anthropogenic NO_x emissions in the Houston‐Galveston‐Brazoria area. We convert slant column densities to vertical columns using a radiative transfer model with (i) NO_2 profiles from a high‐resolution regional model (1 × 1 km^2) constrained by P‐3B aircraft measurements, (ii) the consideration of aerosol optical thickness impacts on radiance at NO_2 absorption line, and (iii) high‐resolution surface albedo constrained by ground‐based spectrometers. We characterize errors in the GCAS NO_2 columns by comparing them to Pandora measurements and find a striking correlation (r > 0.74) with an uncertainty of 3.5 × 10^(15) molecules cm^(−2). On 9 of 10 total days, the constrained anthropogenic emissions by a Kalman filter yield an overall 2–50% reduction in polluted areas, partly counterbalancing the well‐documented positive bias of the model. The inversion, however, boosts emissions by 94% in the same areas on a day when an unprecedented local emissions event potentially occurred, significantly mitigating the bias of the model. The capability of GCAS at detecting such an event ensures the significance of forthcoming geostationary satellites for timely estimates of top‐down emissions

    Which quality of life score is best for glaucoma patients and why?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The glaucomas are generally asymptomatic diseases until they are very advanced. They affect 2% of the population over 40 years of age and therefore represent a significant public health issue. There have been a number of attempts to develop quality of life scales for the disease. This review discusses the pros and cons of these scales and suggests the best of the current ones for use in a clinical setting.</p> <p>Methods</p> <p>Medline, Embase and Google Scholar were searched for relevant articles. No time period was defined and all types of article were included.</p> <p>Results</p> <p>11 Quality of Life scores were identified that have been used with glaucoma patients.</p> <p>Conclusion</p> <p>There is no generally accepted 'best' Quality of Life instrument for use in glaucoma. Many of the scales are biased towards physical symptoms and do little to address the personal or social factors of the disease. Further work is needed to produce scales that address all these areas as well as being simple to administer in a clinical setting.</p

    Development of a Structural Model Explaining Medication Compliance of Persons with Schizophrenia

    Get PDF
    The purpose of this study was to develop and test a structural model explaining medication compliance of schizophrenia. From a review of the literature, a hypothetical model was developed based on the conceptual framework of the Health Belief Model with medication knowledge, symptom severity and social support as the exogenous variables, and perceived benefits, perceived barriers, substance use and medication compliance as the endogenous variables. Data was collected at various mental health facilities, including psychiatric outpatient clinics of general hospitals and community mental health centers, between March and May, 2001. A structured questionnaire was used by one- on- one interviews to collect data on 208 schizophrenic patients. Well established measurement instruments, with confirmed reliability, were used to assess each method variable. As a result of covariance structural analysis, the hypothetical model was found not to fit the empirical data well, so a parsimonious model was adopted after modifying the model. The final model was able to explain the 33% medication compliance. Medication knowledge, social support and perceived benefits had significant effects on medication compliance. The findings of this study address the importance of medication education and social support to promote medication compliance. It is also suggested that various education programs and support groups are needed to enhance medication compliance

    First Top-Down Estimates of Anthropogenic NO_x Emissions Using High-Resolution Airborne Remote Sensing Observations

    Get PDF
    A number of satellite‐based instruments have become an essential part of monitoring emissions. Despite sound theoretical inversion techniques, the insufficient samples and the footprint size of current observations have introduced an obstacle to narrow the inversion window for regional models. These key limitations can be partially resolved by a set of modest high‐quality measurements from airborne remote sensing. This study illustrates the feasibility of nitrogen dioxide (NO_2) columns from the Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) to constrain anthropogenic NO_x emissions in the Houston‐Galveston‐Brazoria area. We convert slant column densities to vertical columns using a radiative transfer model with (i) NO_2 profiles from a high‐resolution regional model (1 × 1 km^2) constrained by P‐3B aircraft measurements, (ii) the consideration of aerosol optical thickness impacts on radiance at NO_2 absorption line, and (iii) high‐resolution surface albedo constrained by ground‐based spectrometers. We characterize errors in the GCAS NO_2 columns by comparing them to Pandora measurements and find a striking correlation (r > 0.74) with an uncertainty of 3.5 × 10^(15) molecules cm^(−2). On 9 of 10 total days, the constrained anthropogenic emissions by a Kalman filter yield an overall 2–50% reduction in polluted areas, partly counterbalancing the well‐documented positive bias of the model. The inversion, however, boosts emissions by 94% in the same areas on a day when an unprecedented local emissions event potentially occurred, significantly mitigating the bias of the model. The capability of GCAS at detecting such an event ensures the significance of forthcoming geostationary satellites for timely estimates of top‐down emissions

    Spectral retrieval techniques for high-resolution Fourier-transform micro-spectrometers

    Get PDF
    Spatial heterodyne Fourier transform (SHFT) spectroscopy is based on simultaneous interferometric measurements implementing linearly increasing optical path differences, hence circumventing the need for mechanical components of traditional Fourier transform spectroscopy schemes. By taking advantage of the high mode confinement of the Silicon-on-Insulator (SOI). platform, great interferometric lengths can be implemented in a reduced footprint, hence increasing the resolution of the device. However, as resolution increases, spectrometers become progressively more sensitive to environmental conditions, and new spectral retrieval techniques are required. In this work, we present several software techniques that enhance the operation of high-resolution SHFT micro-spectrometers. Firstly, we present two techniques for mitigating and correcting the effects of temperature drifts, based on a temperature-sensitive calibration and phase errors correction. Both techniques are demonstrated experimentally on a 32 Mach-Zehnder interferometers array fabricated in a Silicon-on-insulator chip with microphotonic spirals of linearly increasing length up to 3.779 cm. This configuration provides a resolution of 17 pm in a compact device footprint of 12 mm(2). Secondly, we propose the application of compressive-sensing (CS) techniques to SHFT micro-spectrometers. By assuming spectrum sparsity, an undersampled discrete Fourier interferogram is inverted using l1-norm minimization to retrieve the input spectrum. We demonstrate this principle on a subwavelength-engineered SHFT with 32 MZIs and a 50 pm resolution. Correct retrieval of three sparse input signals was experimentally demonstrated using data from 14 or fewer MZIs and applying common CS reconstruction techniques to this data
    • 

    corecore