1,213 research outputs found

    Unmappable ventricular tachycardia after an old myocardial infarction. Long-term results of substrate modification in patients with an implantable cardioverter defibrillator

    Get PDF
    Purpose The frequent occurrence of ventricular tachycardia can create a serious problem in patients with an implantable cardioverter defibrillator. We assessed the long-term efficacy of catheter-based substrate modification using the voltage mapping technique of infarct-related ventricular tachycardia and recurrent device therapy. Methods The study population consisted of 27 consecutive patients (age 68 +/- 8 years, 25 men, mean left ventricular ejection fraction 31 +/- 9%) with an old myocardial infarction and multiple and/or hemodynamically not tolerated ventricular tachycardia necessitating repeated device therapy. A total of 31 substrate modification procedures were performed using the three-dimensional electroanatomical mapping system. Patients were followed up for a median of 23.5 (interquartile range 6.5-53.2) months before and 37.8 (interquartile range 11.7-71.8) months after ablation. Antiarrhythmic drugs were not changed after the procedure, and were stopped 6 to 9 months after the procedure in patients who did not show ventricular tachycardia recurrence. Results Median ventricular tachycardias were 1.6 (interquartile range 0.7-6.7) per month before and 0.2 (interquartile range 0.00-1.3) per month after ablation (P = 0.006). Nine ventricular fibrillation episodes were registered in seven patients before and two after ablation (P = 0.025). Median antitachycardia pacing decreased from 1.6 (interquartile range 0.01-5.5) per month before to 0.18 (interquartile range 0.00-1.6) per month after ablation (P = 0.069). Median number of shocks decreased from 0.19 (interquartile range 0.04-0.81) per month before to 0.00 (interquartile range 0.00-0.09) per month after ablation (P = 0.001). One patient had a transient ischemic attack during the procedure, and another developed pericarditis. Nine patients died during follow-up, eight patients due to heart failure and one patient during valve surgery. Conclusion Catheter-based substrate modification using voltage mapping results in a long-lasting reduction of cardioverter defibrillator therapy in patients with multiple and/or hemodynamically not tolerated infarct-related ventricular tachyarrhythmia

    Equivalence of plasma p-tau217 with cerebrospinal fluid in the diagnosis of Alzheimer's disease

    Get PDF
    INTRODUCTION: Plasma biomarkers are promising tools for Alzheimer's disease (AD) diagnosis, but comparisons with more established biomarkers are needed. METHODS: We assessed the diagnostic performance of p-tau181, p-tau217, and p-tau231 in plasma and CSF in 174 individuals evaluated by dementia specialists and assessed with amyloid-PET and tau-PET. Receiver operating characteristic (ROC) analyses assessed the performance of plasma and CSF biomarkers to identify amyloid-PET and tau-PET positivity. RESULTS: Plasma p-tau biomarkers had lower dynamic ranges and effect sizes compared to CSF p-tau. Plasma p-tau181 (AUC = 76%) and p-tau231 (AUC = 82%) assessments performed inferior to CSF p-tau181 (AUC = 87%) and p-tau231 (AUC = 95%) for amyloid-PET positivity. However, plasma p-tau217 (AUC = 91%) had diagnostic performance indistinguishable from CSF (AUC = 94%) for amyloid-PET positivity. DISCUSSION: Plasma and CSF p-tau217 had equivalent diagnostic performance for biomarker-defined AD. Our results suggest that plasma p-tau217 may help reduce the need for invasive lumbar punctures without compromising accuracy in the identification of AD. Highlights: p-tau217 in plasma performed equivalent to p-tau217 in CSF for the diagnosis of AD, suggesting the increased accessibility of plasma p-tau217 is not offset by lower accuracy. p-tau biomarkers in plasma had lower mean fold-changes between amyloid-PET negative and positive groups than p-tau biomarkers in CSF. CSF p-tau biomarkers had greater effect sizes than plasma p-tau biomarkers when differentiating between amyloid-PET positive and negative groups. Plasma p-tau181 and plasma p-tau231 performed worse than p-tau181 and p-tau231 in CSF for AD diagnosis

    Plasma pTau-217 and N-terminal tau (NTA) enhance sensitivity to identify tau PET positivity in amyloid-ÎČ positive individuals

    Get PDF
    INTRODUCTION: We set out to identify tau PET-positive (A+T+) individuals among amyloid-beta (AÎČ) positive participants using plasma biomarkers. METHODS: In this cross-sectional study we assessed 234 participants across the AD continuum who were evaluated by amyloid PET with [18F]AZD4694 and tau-PET with [18F]MK6240 and measured plasma levels of total tau, pTau-181, pTau-217, pTau-231, and N-terminal tau (NTA-tau). We evaluated the performances of plasma biomarkers to predict tau positivity in AÎČ+ individuals. RESULTS: Highest associations with tau positivity in AÎČ+ individuals were found for plasma pTau-217 (AUC [CI95%] = 0.89 [0.82, 0.96]) and NTA-tau (AUC [CI95%] = 0.88 [0.91, 0.95]). Combining pTau-217 and NTA-tau resulted in the strongest agreement (Cohen's Kappa = 0.74, CI95% = 0.57/0.90, sensitivity = 92%, specificity = 81%) with PET for classifying tau positivity. DISCUSSION: The potential for identifying tau accumulation in later Braak stages will be useful for patient stratification and prognostication in treatment trials and in clinical practice. Highlights: We found that in a cohort without pre-selection pTau-181, pTau-217, and NTA-tau showed the highest association with tau PET positivity. We found that in AÎČ+ individuals pTau-217 and NTA-tau showed the highest association with tau PET positivity. Combining pTau-217 and NTA-tau resulted in the strongest agreement with the tau PET-based classification

    DNA Fingerprinting Validates Seed Dispersal Curves from Observational Studies in the Neotropical Legume Parkia

    Get PDF
    Background: Determining the distances over which seeds are dispersed is a crucial component for examining spatial patterns of seed dispersal and their consequences for plant reproductive success and population structure. However, following the fate of individual seeds after removal from the source tree till deposition at a distant place is generally extremely difficult. Here we provide a comparison of observationally and genetically determined seed dispersal distances and dispersal curves in a Neotropical animal-plant system. Methodology/Principal Findings: In a field study on the dispersal of seeds of three Parkia (Fabaceae) species by two Neotropical primate species, Saguinus fuscicollis and Saguinus mystax, in Peruvian Amazonia, we observationally determined dispersal distances. These dispersal distances were then validated through DNA fingerprinting, by matching DNA from the maternally derived seed coat to DNA from potential source trees. We found that dispersal distances are strongly rightskewed, and that distributions obtained through observational and genetic methods and fitted distributions do not differ significantly from each other. Conclusions/Significance: Our study showed that seed dispersal distances can be reliably estimated through observational methods when a strict criterion for inclusion of seeds is observed. Furthermore, dispersal distances produced by the two primate species indicated that these primates fulfil one of the criteria for efficient seed dispersers. Finally, our stud

    Pressure during decision making of continuous sedation in end-of-life situations in Dutch general practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Little is known about pressure from patients or relatives on physician’s decision making of continuous palliative sedation. We aim to describe experienced pressure by general practitioners (GPs) in cases of continuous sedation after the introduction of the Dutch practice guideline, using a questionnaire survey.</p> <p>Methods</p> <p>A sample of 918 Dutch GPs were invited to fill out a questionnaire about their last patient under continuous sedation. Cases in which GPs experienced pressure from the patient, relatives or other persons were compared to those without pressure.</p> <p>Results</p> <p>399 of 918 invite GPs (43%) returned the questionnaire and 250 provided detailed information about their most recent case of continuous sedation. Forty-one GPs (16%) indicated to have experienced pressure from the patient, relatives or colleagues. In GPs younger than 50, guideline knowledge was not related to experienced pressure, whereas in older GPs, 15% with and 36% without guideline knowledge reported pressure. GPs experienced pressure more often when patients had psychological symptoms (compared to physical symptoms only) and when patients had a longer estimated life expectancy. A euthanasia request of the patient coincided with a higher prevalence of pressure for GPs without, but not for GPs with previous experience with euthanasia. GPs who experienced pressure had consulted a palliative consultation team more often than GPs who did not experience pressure.</p> <p>Conclusion</p> <p>One in six GPs felt pressure from patients or relatives to start sedation. This pressure was related to guideline knowledge, especially in older GPs, longer life expectancy and the presence of a euthanasia request, especially for GPs without previous experience of euthanasia.</p

    The therapeutic potential of attentional bias modification training for insomnia: study protocol for a randomised controlled trial.

    Get PDF
    The efficacy of attentional bias modification (ABM) as a treatment for anxiety and depression has been extensively studied with promising results. Despite some evidence of sleep-related attentional biases in insomnia, only a small number of studies, yielding mixed results, have examined the application of ABM in insomnia. This study specifically aims to determine whether ABM can reduce (i) the presence of an attentional bias for sleep-related threatening words; (ii) insomnia symptom severity; (iii) sleep onset latency; and (iv) pre-sleep cognitive arousal amongst individuals with insomnia compared to a non-treatment control group of individuals with insomnia. We propose a randomised controlled trial of 90 individuals from the general population who meet the criteria for Insomnia Disorder. Following an initial examination for the presence of a sleep-related attentional bias using the dot-probe paradigm, participants will be randomised to an online attentional bias modification training condition, or to a standard attentional bias task (non-treatment) control condition. Both conditions will be delivered online by a web platform. All participants allocated to the non-treatment control group will be offered ABM training once the study is complete. The primary outcome will be the attentional bias indices of vigilance and disengagement and self-reported insomnia symptoms, sleep onset latency and pre-sleep cognitive arousal. Attentional bias and insomnia symptoms will be assessed at baseline (day 1) and post-treatment (2 days after the final training session: day 9). Insomnia symptoms will be again assessed at follow-up (day 16). Secondary outcomes include examining whether sleep associated monitoring and worry are related to a sleep-related attentional bias in insomnia, and whether such reports reduce following ABM. All main analyses will be carried out on completion of follow-up assessments. The trial is supported by the Department of Psychology, Sociology and Politics at Sheffield Hallam University. This study will extend the research base examining the efficacy of attentional bias modification for insomnia. ISRCTN ( ISRCTN11643569 , registered on 5 June 2018)

    A change in the optical polarization associated with a gamma-ray flare in the blazar 3C 279

    Get PDF
    It is widely accepted that strong and variable radiation detected over all accessible energy bands in a number of active galaxies arises from a relativistic, Doppler-boosted jet pointing close to our line of sight. The size of the emitting zone and the location of this region relative to the central supermassive black hole are, however, poorly known, with estimates ranging from light-hours to a light-year or more. Here we report the coincidence of a gamma-ray flare with a dramatic change of optical polarization angle. This provides evidence for co-spatiality of optical and gamma-ray emission regions and indicates a highly ordered jet magnetic field. The results also require a non-axisymmetric structure of the emission zone, implying a curved trajectory for the emitting material within the jet, with the dissipation region located at a considerable distance from the black hole, at about 10^5 gravitational radii.Comment: Published in Nature issued on 18 February 2010. Corresponding authors: Masaaki Hayashida and Greg Madejsk
    • 

    corecore