2,987 research outputs found

    Job Security, Managerial Prerogatives, and \u3cem\u3eFirst National Maintenance\u3c/em\u3e

    Get PDF

    Performance of the distributed central analysis in BaBar

    Get PDF
    The total dataset produced by the BaBar experiment at the Stanford Linear Accelerator Center (SLAC) currently comprises roughly3times1093times 10^9data events and an equal amount of simulated events, corresponding to 23 Tbytes of real data and 51 Tbytes simulated events. Since individual analyses typically select a very small fraction of all events, it would be extremely inefficient if each analysis had to process the full dataset. A first, centrally managed analysis step is therefore a common pre-selection (‘skimming’) of all data according to very loose, inclusive criteria to facilitate data access for later analysis. Usually, there are common selection criteria for several analysis. However, they may change over time, e.g., when new analyses are developed. Currently,$cal

    Spin dynamics in p-doped semiconductor nanostructures subject to a magnetic field tilted from the Voigt geometry

    Get PDF
    We develop a theoretical description of the spin dynamics of resident holes in a p-doped semiconductor quantum well (QW) subject to a magnetic field tilted from the Voigt geometry. We find the expressions for the signals measured in time-resolved Faraday rotation (TRFR) and resonant spin amplification (RSA) experiments and study their behavior for a range of system parameters. We find that an inversion of the RSA peaks can occur for long hole spin dephasing times and tilted magnetic fields. We verify the validity of our theoretical findings by performing a series of TRFR and RSA experiments on a p-modulation doped GaAs/Al_{0.3}Ga_{0.7}As single QW and showing that our model can reproduce experimentally observed signals.Comment: 9 pages, 3 figures; corrected typo

    Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B

    Get PDF
    The results of five years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about 20 * 20 cm2 each. The detector is based on microstrip gas counters (MSGCs) with diamond like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.Comment: 29 pages, 22 figure

    Light Meson Dynamics Workshop. Mini proceedings

    Full text link
    The mini-proceedings of the Light Meson Dynamics Workshop held in Mainz from February 10th to 12th, 2014, are presented. The web page of the conference, which contains all talks, can be found at https://indico.cern.ch/event/287442/overview .Comment: 46 pages, 17 contributions. Editors: W. Gradl, P. Masjuan, M. Ostrick, and S. Schere

    Comparison of contrast enhanced color Doppler targeted biopsy to conventional systematic biology: Impact on Gleason score

    Get PDF
    Purpose: Prostate cancer grading with Gleason score is an important prognostic factor. This prospective randomized study compares ultrasound systematic biopsy vs contrast enhanced color Doppler targeted biopsy for the impact on Gleason score findings. Materials and Methods: We examined 690 men (mean age 56 years, range 41 to 77) with a serum total prostate specific antigen of 1.25 ng/ml or greater, a free-to-total prostate specific antigen ratio less than 18% and/or a suspicious digital rectal examination. Contrast enhanced color Doppler targeted biopsies with a limited number of cores (5 or less) were performed in hypervascular areas of the peripheral zone during administration of the ultrasound contrast agent SonovueTM(Bracco, Milano, Italy). Ten systematic biopsies were obtained in a standard spatial distribution. Cancer detection rates and Gleason score were compared. Results: Prostate cancer was identified in 221 of 690 subjects (32%) with a mean prostate specific antigen of 4.6 ng/ml (range 1.4 to 35.0). Prostate cancer was detected in 180 of 690 subjects (26%) with contrast enhanced color Doppler targeted biopsy and in 166 of 690 patients (24%) with systematic ultrasound biopsy. The Gleason score of all 180 cancers detected on contrast enhanced color Doppler targeted biopsy was 6 or higher (mean 6.8). The Gleason score of all 166 cancers detected on systematic biopsy ranged from 4 to 6 and mean Gleason score was 5.4. Contrast enhanced color Doppler targeted biopsy detected significantly higher Gleason scores compared to systematic biopsy (Wilcoxon rank sum test p \u3c0.003). Conclusions: Contrast enhanced color Doppler targeted biopsy detected cancers with higher Gleason scores and more cancer than systematic biopsy. Therefore, contrast enhanced color Doppler seems to be helpful in the grading of prostate cancer, which is important for defining prognosis and deciding treatment

    Issues and Opportunities in Exotic Hadrons

    Full text link
    The last few years have been witness to a proliferation of new results concerning heavy exotic hadrons. Experimentally, many new signals have been discovered that could be pointing towards the existence of tetraquarks, pentaquarks, and other exotic configurations of quarks and gluons. Theoretically, advances in lattice field theory techniques place us at the cusp of understanding complex coupled-channel phenomena, modelling grows more sophisticated, and effective field theories are being applied to an ever greater range of situations. It is thus an opportune time to evaluate the status of the field. In the following, a series of high priority experimental and theoretical issues concerning heavy exotic hadrons is presented.Comment: White paper from INT workshop, "Modern Exotic Hadrons". References added. Version to appear in Chinese Physics

    Measurement of the transverse target and beam-target asymmetries in η\eta meson photoproduction at MAMI

    Get PDF
    We present new data for the transverse target asymmetry T and the very first data for the beam-target asymmetry F in the γpηp\vec \gamma \vec p\to\eta p reaction up to a center-of-mass energy of W=1.9 GeV. The data were obtained with the Crystal-Ball/TAPS detector setup at the Glasgow tagged photon facility of the Mainz Microtron MAMI. All existing model predictions fail to reproduce the new data indicating a significant impact on our understanding of the underlying dynamics of η\eta meson photoproduction. The peculiar nodal structure observed in existing T data close to threshold is not confirmed.Comment: 5 pages, 3 figures, accepted for publication in PR

    T and F asymmetries in π0 photoproduction on the proton

    Get PDF
    The γp→π0p reaction was studied at laboratory photon energies from 425 to 1445 MeV with a transversely polarized target and a longitudinally polarized beam. The beam-target asymmetry F was measured for the first time and new high precision data for the target asymmetry T were obtained. The experiment was performed at the photon tagging facility of the Mainz Microtron (MAMI) using the Crystal Ball and TAPS photon spectrometers. The polarized cross sections were expanded in terms of associated Legendre functions and compared to recent predictions from several partial-wave analyses. The impact of the new data on our understanding of the underlying partial-wave amplitudes and baryon resonance contributions is discussed
    corecore