195 research outputs found

    Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?

    Get PDF
    Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operatively measured (using portable imaging) anteversions and vertical inclinations of acetabular components with those measured using standardized radiographs post-operatively in 40 patients. Of the all vertical inclinations measured from intra-operative radiographs, 72.5% (n=29) were within ±2°, and 97.5% (n=39) were within ±5° of those determined using post-operative radiographs, and for anteversion, 52.5% (n=21) were within ±2°, and 97.5% (n=39) were within ±5°. Post-operative radiographs demonstrated that 90.0% (n=36) of vertical inclinations and anteversions were within the adequate zone. Obviously, our method has its limitations, but the authors conclude that the method described in this article better allows surgeons to verify acetabular version intra-operatively. In particular, the described method is suitable in cases with a deformed acetabular anatomy and difficult revision surgery

    Cementless Total Hip Replacement for the Management of Severe Developmental Dysplasia of the Hip in the Middle Eastern Population: A Prospective Analysis

    Get PDF
    Introduction: In the Middle East, severe developmental dysplasia of the hip with subsequent high dislocation is often seen. We assessed the efficiency of total hip replacement (THR) with subtrochanteric shortening femoral osteotomy and trochanteric advancement in this population. Methods: This prospective study assessed 25 female patients with symptomatic and severe (Crowe IV). Pre- and postoperative Harris hip score (HHS) and Oxford hip score (OHS) were performed alongside assessment of leg length discrepancy (LLD) and the ability to sit in a cross-legged position. Results: The mean HHS and OHS improved pre-operatively at 1 and 10 years, respectively (p-value < 0.001). The mean postoperative LLD was 3 mm (0–8 mm). Functionally, 22/25 patients were able to sit cross-legged. None of the 25 hips underwent revision during this period. Conclusion: Total hip replacement with subtrochanteric shortening osteotomy in combination with trochanteric advancement is sufficient for the management of Crowe type IV hips in this population

    Long-term results of 32-mm alumina-on-alumina THA for avascular necrosis of the femoral head

    Get PDF
    BACKGROUND: Ceramic bearings in total hip arthroplasty (THA) have been introduced in clinical practice to minimize the problem of polyethylene particle-induced osteolysis. The aim of the study is to report the results of 68 consecutive alumina-on-alumina THAs done in 61 patients for avascular necrosis (AVN) of the femoral head. MATERIALS AND METHODS: In all implants a press-fit cup was used; it was combined with a 32-mm alumina head and with titanium-alloy stems. The mean age at surgery was 50 years. At an average follow-up of 13 years two hips have been revised, one for periprosthetic infection and one for excessive abduction of the cup. RESULTS: No revision for aseptic loosening is recorded; one anatomical cementless femoral stem had radiological evidence of definite aseptic loosening. No dislocations occurred, and no osteolysis was observed. CONCLUSIONS: The results support the application of alumina-alumina THA for long-lasting replacements

    Is an Impacted Morselized Graft in a Cage an Alternative for Reconstructing Segmental Diaphyseal Defects?

    Get PDF
    Large diaphyseal bone defects often are reconstructed with large structural allografts but these are prone to major complications. We therefore asked whether impacted morselized bone graft could be an alternative for a massive structural graft in reconstructing large diaphyseal bone defects. Defects in the femora of goats were reconstructed using a cage filled with firmly impacted morselized allograft or with a structural cortical autograft (n = 6 in both groups). All reconstructions were stabilized with an intramedullary nail. The goats were allowed full weightbearing. In all reconstructions, the grafts united radiographically. Mechanical torsion strength of the femur with the cage and structural cortical graft reconstructions were 66.6% and 60.3%, respectively, as compared with the contralateral femurs after 6 months. Histologically, the impacted morselized graft was replaced completely by new viable bone. In the structural graft group, a mixture of new and necrotic bone was present. Incorporation of the impacted graft into new viable bone suggests this type of reconstruction may be safer than reconstruction with a structural graft in which creeping substitution results in a mixture of viable and necrotic bone that can fracture. The data suggest that a cage filled with a loaded morselized graft could be an alternative for the massive cortical graft in reconstruction of large diaphyseal defects in an animal model

    Curved versus Straight Stem Uncemented Total Hip Arthroplasty Osteoarthritis Multicenter trial (CUSTOM): Design of a prospective blinded randomised controlled multicentre trial

    Get PDF
    Introduction: Answering the demands of an increasingly young and active patient population, recent developments in total hip arthroplasty (THA) have shifted towards minimising tissue damage. The Collum Femoris Preserving (CFP) stem was developed to preserve the trochanteric region of the femur, which potentially preserves the insertion of the gluteus musculature. This might accelerate early postoperative rehabilitation and improve functional outcome. Currently the functional results of the CFP stem have not been compared with conventional straight stems in a randomised controlled trial (RCT). The primary purpose of this trial is to compare the functional result of CFP stem THA with conventional uncemented straight stem THA, measured by the Dutch Hip disability and Osteoarthritis Outcome Score (HOOS) at 3-month follow-up. Methods: A prospective blinded multicentre RCT will be performed. We aim to recruit 150 patients. The patients will be randomly allocated to a THA with a straight or a curved stem. All patients, research assistants, clinical assessors and investigators will be blinded for the type of prosthesis for 5 years. Clinical assessments and roentgenograms will be taken preoperative, at 6 weeks after surgery, at 1, 2, 3, 4 and 5 years after surgery. Patient reported outcome measures (PROMs) will be obtained at the same follow-up moments. In addition, the PROMs will also be sent to the patients at 3 and 6 months after surgery. The HOOS at 3-month follow-up will be our primary outcome. Ethics and dissemination: This trial will be performed in accordance with the Declaration of Helsinki. A local ethics committee has approved this trial. Written informed consent will be obtained from all participating patients. All serious adverse events will be reported to the ethics committee. Results: Results will be submitted for publication to an orthopaedics related journal

    Polyethylene Oxidation in Total Hip Arthroplasty: Evolution and New Advances

    Get PDF
    Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs

    Basic Science Considerations in Primary Total Hip Replacement Arthroplasty

    Get PDF
    Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement

    Periprosthetic osteolysis after total hip replacement: molecular pathology and clinical management

    Get PDF
    Periprosthetic osteolysis is a serious complication of total hip replacement (THR) in the medium to long term. Although often asymptomatic, osteolysis can lead to prosthesis loosening and periprosthetic fracture. These complications cause significant morbidity and require complex revision surgery. Here, we review advances in our understanding of the cell and tissue response to particles produced by wear of the articular and non-articular surfaces of prostheses. We discuss the molecular and cellular regulators of osteoclast formation and bone resorptive activity, a better understanding of which may lead to pharmacological treatments for periprosthetic osteolysis. We describe the development of imaging techniques for the detection and measurement of osteolysis around THR prostheses, which enable improved clinical management of patients, provide a means of evaluating outcomes of non-surgical treatments for periprosthetic osteolysis, and assist in pre-operative planning for revision surgery. Finally, there have been advances in the materials used for bearing surfaces to minimise wear, and we review the literature regarding the performance of these new materials to date.Donald W. Howie, Susan D. Neale, David R. Haynes, Oksana T. Holubowycz, Margaret A. McGee, Lucian B. Solomon, Stuart A. Callary, Gerald J. Atkins, David M. Findla
    corecore