125 research outputs found

    Theoretical considerations on the land as pure financial asset and the financialization process

    Get PDF
    O presente artigo tem dois objetivos: 1) precisar conceitos que estão envolvidos na relação entre o mercado imobiliário e a financeirização da acumulação de capital; e 2) aprofundar a reflexão sobre as contradições existentes no tratamento da terra como puro ativo financeiro. Sempre que possível, exemplos concretos serão trazidos para ilustrar esse esforço conceitual394638657CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQCOORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESSem informaçãoSem informaçãoThe present article has two goals: 1) to specify the concepts involved in the relationship between the real estate market and the financialisation of capital accumulation; and 2) to reflect more deeply on the contradictions of treating the land as a pure financial asset. In both cases, whenever possible, concrete examples will be brought to illustrate this conceptual effor

    Avaliação visual de sujeitos expostos de forma ocupacional a solventes orgânicos através de métodos psicofísicos

    Get PDF
    Les solvants organiques sont des substances neurotoxiques que peuvent causer des effets préjudiciables dans le système visuel. Lexposition professionnelle de ces types de substances est commune parce quils sont utilisés dans une grande variété dactivités. Ces effets peuvent être quantifiés par des tests spécifiques de psychophysique. Les tests les plus utilisés dans cette évaluation sont, pour la vision des couleurs, le Lanthony Panel D-15 désaturé et le test Farnsworth-Munsell 100-Hue, et pour lévaluation de la sensibilité au contraste, le MCT 8000 Vistech, le VCTS 6500 Vistech et le FACT 101. Généralement, ces tests révèlent une réduction de discrimination des couleurs, des effets dans les axes bleu-jaune et rouge-vert, et une diminution de sensibilité au contraste, spécialement dans les basses fréquences spatiales. Il y a une corrélation positive entre les résultats psychophysiques et les marqueurs biologiques environnementaux, mais cette corrélation dépend du marqueur et du type de solvant auquel le sujet a été exposé. Des facteurs tels que lalcool et le tabac peut nuire à la corrélation des résultats.Los solventes orgánicos son sustancias neurotóxicas que pueden causar efectos dañinos en el sistema visual. La exposición ocupacional a estas sustancias es común, ya que se utilizan en una amplia variedad de actividades. Estos efectos pueden ser cuantificados por las pruebas psicofísicas específicas. Las pruebas más utilizadas para la evaluación de la visión del color son las pruebas de acuerdo, tales como el Panel de Lanthony D-15 desaturado de prueba y la prueba de Farnsworth-Munsell 100-hue, y para evaluar la sensibilidad al contraste, pruebas impresas panel como el MCT 8000 VISTECH, VCTS 6500VISTECH, y el hecho 101 pruebas. En general, estas pruebas demuestran que las pérdidas de color la discriminación en el eje azul-amarillo y rojo-verde, y una disminución de la sensibilidad al contraste, sobre todo a bajas frecuencias espaciales. Hay una correlación positiva entre los resultados de estudios biológicos y psicofísicos marcadores del medio ambiente, pero esta relación depende de la marca y del tipo de disolvente para que los individuos estén expuestos. Factores tales como el alcohol y el tabaco pueden interferir con la correlación de los resultados.Organic solvents are neurotoxic substances that can cause damaging effects in the visual system. Occupational exposure to these substances is common because they are used in a wide variety of activities. These effects can be quantified by specific psychophysical tests. The most commonly used tests for color vision assessment are arrangement tests, such as the Lanthony Panel D-15 desaturated test and the Farnsworth-Munsell 100-hue test, and for contrast sensitivity assessment, printed panel tests such as the MCT 8000 VISTECH, VCTS 6500VISTECH, and FACT 101 tests. Generally, these tests show color discrimination losses in the blue-yellow and red-green axis, and a decrease in contrast sensitivity, mainly at low spatial frequencies. There is a positive correlation between psychophysical results and biological environmental markers, but this correlation depends on the marker and on the kind of solvent to which the individuals are exposed. Factors such as alcohol and tobacco can interfere with the correlation of the results.Os solventes orgânicos são substâncias neurotóxicas que podem causar efeitos danosos sobre as funções visuais. É comum a exposição ocupacional a esses tipos de substâncias, pois elas apresentam grande aplicabilidade em inúmeras atividades. Os efeitos podem ser quantificados por testes psicofísicos. Os testes mais usados nesse tipo de avaliação são de ordenamento de matizes, como o Teste D15 Dessaturado de Lanthony e o Teste dos 100 Matizes de Farnsworth-Munsell, e avaliação de sensibilidade ao contraste espacial de luminância, como MCT 8000 Vistech, VCTS 6500 Vistech e FACT 101. Em geral esses testes descrevem perda de discriminação de cores, afetando tanto o eixo azul-amarelo quanto o eixo verde-vermelho, e diminuição da sensibilidade ao contraste de luminância principalmente para as frequências espaciais mais baixas. Existe correlação positiva entre os resultados da avaliação psicofísica e vários marcadores biológicos e ambientais, mas essa correlação depende do marcador e do tipo de solvente ao qual os indivíduos são expostos. Fatores como alcoolismo crônico e tabagismo inveterado podem interferir no processo de correlacionar esses resultados

    Neuromotor development and visual acuity in premature infants submitted to early visuo-motor stimulation

    Get PDF
    To investigate the effects of early visual stimulation on the development of tonus and posture control and of grating visual acuity of preterm infants, eight infants received visual stimulation that induced head motion during the first 6 months of life in weekly sessions. Their performance was compared with that of unstimulated preterm infants of same age (n = 6). Both groups were evaluated in the developmental scale of Gesell and had their grating visual acuity measured by swept visually evoked potentials (sweep-VEP). Visuomotor performance and adoption and maintenance of postures were significantly better for the stimulated group (p < .05) compared to the unstimulated group. There was no statistical difference between the two groups for the development of visual acuity. Visuo-motor and postural development improved with the early visuo-motor stimulation program. The lack of influence of this program in the development of visual acuity may be attributed to differences in the pathways involved in the processing of visual acuity of patterns and in the responses elicited by visuo-motor stimulation.Universidade de São PauloUniversidade Federal de São Paulo (UNIFESP)UNIFESPSciEL

    Scalable Synthesis of 5,11-diethynylated Indeno[1,2-\u3cem\u3eb\u3c/em\u3e]fluorene-6,12-diones and Exploration of Their Solid State Packing

    Get PDF
    We report a new synthetic route to 5,11-disubstituted indeno[1,2-b]fluorene-6,12-diones that is amenable to larger scale reactions, allowing for the preparation of gram amounts of material. With this new methodology, we explored the effects on crystal packing morphology for the indeno[1,2-b]fluorene-6,12-diones by varying the substituents on the silylethynyl groups

    Psychophysical Evaluation of Achromatic and Chromatic Vision of Workers Chronically Exposed to Organic Solvents

    Get PDF
    The purpose of this paper was to evaluate achromatic and chromatic vision of workers chronically exposed to organic solvents through psychophysical methods. Thirty-one gas station workers (31.5 ± 8.4 years old) were evaluated. Psychophysical tests were achromatic tests (Snellen chart, spatial and temporal contrast sensitivity, and visual perimetry) and chromatic tests (Ishihara's test, color discrimination ellipses, and Farnsworth-Munsell 100 hue test—FM100). Spatial contrast sensitivities of exposed workers were lower than the control at spatial frequencies of 20 and 30 cpd whilst the temporal contrast sensitivity was preserved. Visual field losses were found in 10–30 degrees of eccentricity in the solvent exposed workers. The exposed workers group had higher error values of FM100 and wider color discrimination ellipses area compared to the controls. Workers occupationally exposed to organic solvents had abnormal visual functions, mainly color vision losses and visual field constriction

    Mercury toxicity in the Amazon: contrast sensitivity and color discrimination of subjects exposed to mercury

    Get PDF
    We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity

    Vitreous pharmacokinetics and electroretinographic findings after intravitreal injection of acyclovir in rabbits

    Get PDF
    OBJECTIVES: Acute retinal necrosis is a rapidly progressive and devastating viral retinitis caused by the herpesvirus family. Systemic acyclovir is the treatment of choice; however, the progression of retinal lesions ceases approximately 2 days after treatment initiation. An intravitreal injection of acyclovir may be used an adjuvant therapy during the first 2 days of treatment when systemically administered acyclovir has not reached therapeutic levels in the retina. The aims of this study were to determine the pharmacokinetic profile of acyclovir in the rabbit vitreous after intravitreal injection and the functional effects of acyclovir in the rabbit retina. METHODS: Acyclovir (Acyclovir; Bedford Laboratories, Bedford, OH, USA) 1 mg in 0.1 mL was injected into the right eye vitreous of 32 New Zealand white rabbits, and 0.1 mL sterile saline solution was injected into the left eye as a control. The animals were sacrificed after 2, 9, 14, or 28 days. The eyes were enucleated, and the vitreous was removed. The half-life of acyclovir was determined using high-performance liquid chromatography. Electroretinograms were recorded on days 2, 9, 14, and 28 in the eight animals that were sacrificed 28 days after injection according to a modified protocol of the International Society for Clinical Electrophysiology of Vision. RESULTS: Acyclovir rapidly decayed in the vitreous within the first two days after treatment and remained at low levels from day 9 onward. The eyes that were injected with acyclovir did not present any electroretinographic changes compared with the control eyes. CONCLUSIONS: The vitreous half-life of acyclovir is short, and the electrophysiological findings suggest that the intravitreal delivery of 1 mg acyclovir is safe and well tolerated by the rabbit retina.CNPq [150614/2009-8, 1A]CNPqFAPESP [2010/08331-8, 2011/06924-4, 2008/58731-2]FAPES
    corecore