37 research outputs found

    Does Ingestion of Tincture of Opium Notably Raise Blood Alcohol Concentration?‎

    Get PDF
    Background: Tincture of opium (TOP) is currently used for maintenance therapy in treatment of opioids addiction. It contains ethanol. The present study was conducted to assess the increase in blood alcohol concentration (BAC) in its users; a process which may interfere with breath-alcohol test performed by law enforcement or traffic police. Methods: A total of 143 individuals were selected randomly from drug users who had been referred to an addiction treatment clinic. They were asked to undergo breath-alcohol test 15, 30, 45, and 60 min after taking their daily dosage of TOP. The resulting figures were statistically analyzed by t-test and chi-square test using SPSS for Windows. Findings: The calculated blood ethanol concentration rose to 26.33 ± 14.34, 29.15 ± 6.70, and 33.03 ± 8.46 in persons taking 20, 25, and 30 ml TOP respectively, 5 min after their drug ingestion. The figures turned into zero after 15 min. Conclusion: Users of TOP should be reassured about its alcoholic content. Its alcoholic content cannot produce equilibrium disturbance or notable BAC. However, it is recommended that users of TOP are observed in addiction treatment centers for 15 min after taking their drug to reach a higher degree of certainty about any effect of alcoholic content of TOP

    Development and analysis of the Soil Water Infiltration Global database

    Get PDF
    In this paper, we present and analyze a novel global database of soil infiltration measurements, the Soil Water Infiltration Global (SWIG) database. In total, 5023 infiltration curves were collected across all continents in the SWIG database. These data were either provided and quality checked by the scientists who performed the experiments or they were digitized from published articles. Data from 54 different countries were included in the database with major contributions from Iran, China, and the USA. In addition to its extensive geographical coverage, the collected infiltration curves cover research from 1976 to late 2017. Basic information on measurement location and method, soil properties, and land use was gathered along with the infiltration data, making the database valuable for the development of pedotransfer functions (PTFs) for estimating soil hydraulic properties, for the evaluation of infiltration measurement methods, and for developing and validating infiltration models. Soil textural information (clay, silt, and sand content) is available for 3842 out of 5023 infiltration measurements ( ∼ 76%) covering nearly all soil USDA textural classes except for the sandy clay and silt classes. Information on land use is available for 76% of the experimental sites with agricultural land use as the dominant type ( ∼ 40%). We are convinced that the SWIG database will allow for a better parameterization of the infiltration process in land surface models and for testing infiltration models. All collected data and related soil characteristics are provided online in *.xlsx and *.csv formats for reference, and we add a disclaimer that the database is for public domain use only and can be copied freely by referencing it. Supplementary data are available at https://doi.org/10.1594/PANGAEA.885492 (Rahmati et al., 2018). Data quality assessment is strongly advised prior to any use of this database. Finally, we would like to encourage scientists to extend and update the SWIG database by uploading new data to it

    Improvement of dose distributions in abutment regions of intensity modulated radiation therapy and electron fields

    No full text
    In recent years, intensity modulated radiation therapy (IMRT) is used to radiate tumors that are in close proximity to vital organs. Targets consisting of a deep-seated region followed by a superficial one may be treated with abutting photon and electron fields. However, no systematic study regarding matching of IMRT and electron beams was reported. In this work, a study of dose distributions in the abutment region between tomographic and step-and-shoot IMRT and electron fields was carried out. A method that significantly improves dose homogeneity between abutting tomographic IMRT and electron fields was developed and tested. In this method, a target region that is covered by IMRT was extended into the superficial target area by ∼2.0 cm. The length and shape of IMRT target extension was chosen such that high isodose lines bent away from the region treated by the electrons. This reduced the magnitude of hot spots caused by the “bulging effect” of electron field penumbra. To account for the uncertainties in positioning of the IMRT and electron fields, electron field penumbra was modified using conventional (photon) multileaf collimator (MLC). The electron beam was delivered in two steps: half of the dose delivered with MLCs in retracted position and another half with MLCs extended to the edge of electron field that abuts tomographic IMRT field. The experimental testing of this method using film dosimetry has demonstrated that the magnitude of the hot spots was reduced from ∼45% to ∼5% of the prescription dose. When an error of ±1.5 mm in field positioning was introduced, the dose inhomogeneity in the abutment region did not exceed ±15% of the prescription dose. With step-and-shoot IMRT, the most homogeneous dose distribution was achieved when there was a 3 mm gap between the IMRT and electron fields

    Intraoperative Radiotherapy With INTRABEAM: Technical and Dosimetric Considerations

    No full text
    PurposeWe evaluate dose characteristics and clinical applications of treatment accessories used in intraoperative radiotherapy (IORT) and make site-specific recommendations for their optimal use.Methods and materialsDose measurements were performed for a low energy (50 kV) X-ray INTRABEAM source. For spherical, flat, surface, and needle applicators, the following dosimetric parameters were measured: depth-dose (DD) profiles, surface dose (Ds), output factors (OF), and target dose homogeneity (DH). Optical density versus exposure calibration films were employed to obtain 2-dimensional dose distributions in planes parallel and perpendicular to beam direction. Film results were verified via repeat dose measurements with a parallel-plate ionization chamber in a custom water tank. The impact of applicator design on dose distributions was evaluated.ResultsSpherical applicators are commonly used for treating the inner-surface of breast lumpectomy cavity. Flat and surface applicators provide uniform planar dose for head and neck, abdomen, and pelvis targets. Needle applicators are designed for kypho-IORT of spinal metastasis. Typically, larger applicators produce a more homogeneous target dose region with lower surface dose, but require longer treatment times. For 4-cm diameter spherical, flat, and surface applicators, dose rates (DR) at their respective prescription points were found to be: 0.8, 0.3, and 2.2 Gy/min, respectively. The DR for a needle applicator was 7.04 Gy/min at 5 mm distance from the applicator surface. Overall, film results were in excellent agreement with ion-chamber data.ConclusionIORT may be delivered with a variety of site-specific applicators. Appropriate applicator use is paramount for safe, effective, and efficient IORT delivery. Results of this study should help clinicians assure optimized target dose coverage and reduced normal tissue exposure

    Relaxant effect of Curcuma longa on rat tracheal smooth muscle and its possible mechanisms

    No full text
    Context: Turmeric is a spice obtained from the root of Curcuma longa L. (Zingiberaceae) with anti-aging, anticancer, anti-Alzheimer’s disease, antioxidant and other medicinal properties. Objective: The relaxant effect of C. longa on rat tracheal smooth muscle and its possible mechanisms were investigated in this study. Materials and methods: The relaxant effects of four cumulative concentrations of hydro-ethanol extract of C. longa (6.25, 12.5, 25, 50 mg/mL) were studied on tracheal smooth muscle precontracted by methacholine or KCl in non-incubated or incubated with different substances including propranolol, diltiazem, L-NAME, glibenclamide, atropine, chlorpheniramine, indomethacin and papaverine. The duration of the study was 84 days. Results: In non-incubated tracheal smooth muscle, the extract of C. longa showed significant concentration-dependent relaxant effects (p < 0.001 for all concentrations on both KCl and methacholine-induced contraction). There was no significant difference in the relaxant effects between C. longa and theophylline in both methacholine and KCl-induced contraction conditions. In tissues incubated with propranolol, diltiazem, L-NAME and glibenclamide on methacholine-induced contraction and in tissues incubated with atropine, chlorpheniramine, indomethacin and papaverine on KCl-induced contraction, the extract also showed significant concentration-dependent relaxant effects (p < 0.001). EC50 values of C. longa between non-incubated (16.22 ± 0.62) and incubated tissues (atropine: 13.03 ± 0.55, chlorpheniramine: 12.94 ± 0.68, indomethacin: 14.80 ± 0.57 and papaverine: 16.16 ± 1.42) were not significantly different. Conclusions: Tracheal smooth muscle relaxant effects of C. longa, were comparable to those of theophylline, which could be due to the presence of methylxanthines or its possible interaction with non-adrenergic non-cholinergic nervous system

    Horticulture aspects of pistachio

    No full text

    A modified method of planning and delivery for dynamic multileaf collimator intensity-modulated radiation therapy

    No full text
    Purpose: To develop a modified planning and delivery technique that reduces dose nonuniformity for tomographic delivery of intensity-modulated radiation therapy (IMRT). Methods and Materials: The NOMOS-CORVUS system delivers IMRT in a tomographic paradigm. This type of delivery is prone to create multiple dose nonuniformity regions at the arc abutment regions. The modified technique was based on the cyclical behavior of arc positions as a function of a target length. With the modified technique, two plans are developed for the same patient, one with the original target and the second with a slightly increased target length and the abutment regions shifted by ∼5 mm compared to the first plan. Each plan is designed to deliver half of the target prescription dose delivered on alternate days, resulting in periodic shifts of abutment regions. This method was experimentally tested in phantoms with and without intentionally introduced errors in couch indexing. Results: With the modified technique, the degree of dose nonuniformity was reduced. For example, with 1 mm error in couch indexing, the degree of dose nonuniformity changed from ∼25% to ∼12%. Conclusion: Use of the modified technique reduces dose nonuniformity due to periodic shifts of abutment regions during treatment delivery
    corecore