    Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery

    Get PDF
    Aims We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater-cooler unit of the heart-lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Methods and results Interdisciplinary care and follow-up of all patients was documented by the study team. Patients' characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36-76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5-40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Conclusion Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogen

    Emergence of Clostridium difficile infection due to a new hypervirulent strain, polymerase chain reaction ribotype 078

    No full text
    Since 2005, an increase in the prevalence of Clostridium difficile infection (CDI) due to polymerase chain reaction ribotype 078 has been noticed in The Netherlands. This strain has also been identified as the predominant strain in pigs and calves. CDI caused by type 078 was studied in relation to CDI caused by the hypervirulent type 027 and by types other than 027 and 078. Human and porcine isolates were further investigated and characterized by multilocus variable number tandem repeat analysis. From February 2005 through February 2008, the incidence of type 078 among isolates obtained from 1687 patients increased from 3% to 13%. Compared with patients infected with type 027, patients infected with type 078 were younger (67.4 vs. 73.5 years; P <.01) and more frequently had community-associated disease (17.5% vs. 6.7%; odds ratio, 2.98; 95% confidence interval, 2.11-8.02); rates of severe diarrhea (38.9% vs. 40.0%) and attributable mortality (3.8% vs. 4.0%) were similar in both groups. Compared with patients infected with other types, patients infected with type 078 more frequently received fluoroquinolone therapy (29.4% vs. 19.8%; odds ratio, 2.17; 95% confidence interval, 1.06-4.44). Type 078 isolates contained genes for toxin A, toxin B, binary toxin, and a 39-base pair deletion in toxin regulator gene (tcdC), as well as a point mutation at position 184, resulting in a stop codon. Multilocus variable number tandem repeat analysis of 54 human and 11 porcine isolates revealed 4 clonal complexes containing both porcine and human isolates. CDI due to type 078 and CDI due to type 027 present with similar severity, but CDI due to type 078 affects a younger population and is more frequently community associated. C. difficile type 078 isolates from humans and pigs are highly genetically relate

    Detection of SARS-CoV-2 infection in the general population by three prevailing rapid antigen tests: cross-sectional diagnostic accuracy study

    Get PDF
    BACKGROUND: Rapid antigen diagnostic tests (Ag-RDTs) are the most widely used point-of-care tests for detecting SARS-CoV-2 infection. Since the accuracy may have altered by changes in SARS-CoV-2 epidemiology, indications for testing, sampling and testing procedures, and roll-out of COVID-19 vaccination, we evaluated the performance of three prevailing SARS-CoV-2 Ag-RDTs. METHODS: In this cross-sectional study, we consecutively enrolled individuals aged >16 years presenting for SARS-CoV-2 testing at three Dutch public health service COVID-19 test sites. In the first phase, participants underwent either BD-Veritor System (Becton Dickinson), PanBio (Abbott), or SD-Biosensor (Roche Diagnostics) testing with routine sampling procedures. In a subsequent phase, participants underwent SD-Biosensor testing with a less invasive sampling method (combined oropharyngeal-nasal [OP-N] swab). Diagnostic accuracies were assessed against molecular testing. RESULTS: Six thousand nine hundred fifty-five of 7005 participants (99%) with results from both an Ag-RDT and a molecular reference test were analysed. SARS-CoV-2 prevalence and overall sensitivities were 13% (188/1441) and 69% (129/188, 95% CI 62–75) for BD-Veritor, 8% (173/2056) and 69% (119/173, 61–76) for PanBio, and 12% (215/1769) and 74% (160/215, 68–80) for SD-Biosensor with routine sampling and 10% (164/1689) and 75% (123/164, 68–81) for SD-Biosensor with OP-N sampling. In those symptomatic or asymptomatic at sampling, sensitivities were 72–83% and 54–56%, respectively. Above a viral load cut-off (≥5.2 log(10) SARS-CoV-2 E-gene copies/mL), sensitivities were 86% (125/146, 79–91) for BD-Veritor, 89% (108/121, 82–94) for PanBio, and 88% (160/182, 82–92) for SD-Biosensor with routine sampling and 84% (118/141, 77–89) with OP-N sampling. Specificities were >99% for all tests in most analyses. Sixty-one per cent of false-negative Ag-RDT participants returned for testing within 14 days (median: 3 days, interquartile range 3) of whom 90% tested positive. CONCLUSIONS: Overall sensitivities of three SARS-CoV-2 Ag-RDTs were 69–75%, increasing to ≥86% above a viral load cut-off. The decreased sensitivity among asymptomatic participants and high positivity rate during follow-up in false-negative Ag-RDT participants emphasise the need for education of the public about the importance of re-testing after an initial negative Ag-RDT should symptoms develop. For SD-Biosensor, the diagnostic accuracy with OP-N and deep nasopharyngeal sampling was similar; adopting the more convenient sampling method might reduce the threshold for professional testing. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12916-022-02300-9

    Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery

    Full text link
    Aims We identified 10 patients with disseminated Mycobacterium chimaera infections subsequent to open-heart surgery at three European Hospitals. Infections originated from the heater–cooler unit of the heart–lung machine. Here we describe clinical aspects and treatment course of this novel clinical entity. Methods and results Interdisciplinary care and follow-up of all patients was documented by the study team. Patients’ characteristics, clinical manifestations, microbiological findings, and therapeutic measures including surgical reinterventions were reviewed and treatment outcomes are described. The 10 patients comprise a 1-year-old child and nine adults with a median age of 61 years (range 36–76 years). The median duration from cardiac surgery to diagnosis was 21 (range 5–40) months. All patients had prosthetic material-associated infections with either prosthetic valve endocarditis, aortic graft infection, myocarditis, or infection of the prosthetic material following banding of the pulmonary artery. Extracardiac manifestations preceded cardiovascular disease in some cases. Despite targeted antimicrobial therapy, M. chimaera infection required cardiosurgical reinterventions in eight patients. Six out of 10 patients experienced breakthrough infections, of which four were fatal. Three patients are in a post-treatment monitoring period. Conclusion Healthcare-associated infections due to M. chimaera occurred in patients subsequent to cardiac surgery with extracorporeal circulation and implantation of prosthetic material. Infections became clinically apparent after a time lag of months to years. Mycobacterium chimaera infections are easily missed by routine bacterial diagnostics and outcome is poor despite long-term antimycobacterial therapy, probably because biofilm formation hinders eradication of pathogens