129 research outputs found

    New process for the production of permeate powders without spray dryer

    Get PDF
    An innovative process scheme for the production of dairy permeate powders was tested at the pilot scale. It includes: (i) overconcentration of the permeate concentrate from 60 to 80% w/w dry matter (DM) content; (ii) granulation of the overconcentrate with powder up to 88% DM; and (iii) drying of the granules up to 97% DM.The quality of the resulting powder was comparable to a standard powder produced using conventional technologies. Furthermore, considering energy required for water removal, the new process led to significant savings: they were estimated in the range of 10.7 to 23.5% and up to 32% when taking into account the whole production process or the drying step alone, respectively

    Modélisation d'horizons sismiques à l'aide des algorithmes génétiques

    Get PDF
    Dans le contexte de l'analyse des images sismiques, ce travail propose la mise en valeur de structures continues (horizons) par une nouvelle méthode de reconnaissance de formes nommée « approche par correspondance géométrique ». Il s'agit d'une mesure non linéaire de similitude entre vecteurs qui correspondent respectivement, dans notre cas, à un segment particulier et préalablement choisi (horizon de référence) et un segment quelconque de l'image traitée. Le segment dit de référence est représenté par un modÚle polynomial estimé à l'aide des algorithmes génétiques. Nous avons ainsi obtenu une carte d'attribut de similitude qui renforce la géométrie de structures géologiques initialement peu visibles sur une image sismique réelle

    FAME : A new beamline for X-ray absorption investigations of very-diluted systems of environmental, material and biological interests

    Get PDF
    International audienceFAME is the French Absorption spectroscopy beamline in Material and Environmental sciences at the ESRF (France), operational since September 2002. Technically speaking, the source is a 0.85 T bending magnet and the main optical element is a two-crystals monochromator using either Si(111) or Si(220) monocrystals so that the available energy ranges from 4 to 40 keV. The first crystal is liquid nitrogen cooled in order to avoid a thermal bump and thus preserve the energy resolution. The second crystal is dynamically bent during the energy scan in order to focus the beam in the horizontal plane. Two bendable mirrors are located before and after the monochromator, for beam-collimation (to optimize the energy resolution) and vertical focalization, respectively. During scans, the beam on the sample is kept constant in position and size (around 150 × 200 ÎŒm2, V × H). The high flux on the sample combined with the sensitivity of our 30-elements fluorescence detector allow to decrease the detection limit down to 10 ppm or around less than a monolayer. Moreover, quick-EXAFS acquisition is operational: the acquisition time may be reduced down to 30s

    A low-cost HPV immunochromatographic assay to detect high-grade cervical intraepithelial neoplasia

    Get PDF
    Objective To evaluate the reproducibility and accuracy of the HPV16/18-E6 test. Methods The study population was comprised of 448 women with a previously abnormal Pap who were referred to the Barretos Cancer Hospital (Brazil) for diagnosis and treatment. Two cervical samples were collected immediately before colposcopy, one for the hr-HPV-DNA test and cytology and the other for the HPV16/18-E6 test using high-affinity monoclonal antibodies (mAb). Women with a histologic diagnosis of cervical intraepithelial neoplasia grade 2 or 3 were considered to be positive cases. Different strategies using a combination of screening methods (HPV-DNA) and triage tests (cytology and HPV16/18-E6) were also examined and compared. Results The HPV16/18-E6 test exhibited a lower positivity rate compared with the HPV-DNA test (19.0% vs. 29.3%, p<0.001) and a moderate/high agreement (kappa = 0.68, 95% CI: 0.60-0.75). It also exhibited a significantly lower sensitivity for CIN2+ and CIN3+ detection compared to the HPV-DNA test and a significantly higher specificity. The HPV16/18-E6 test was no different from cytology in terms of sensitivity, but it exhibited a significantly higher specificity in comparison to ASCH+. A triage test after HPV-DNA detection using the HPV16/18-E6 test exhibited a significantly higher specificity compared with a triage test of ASCH+ to CIN2+ (91.8% vs. 87.4%, p = 0.04) and CIN3+ (88.6% vs. 84.0%, p = 0.05). Conclusion The HPV16/18-E6 test exhibited moderate/high agreement with the HPV-DNA test but lower sensitivity and higher specificity for the detection of CIN2+ and CIN3+. In addition, its performance was quite similar to cytology, but because of the structural design addressed for the detection of HPV16/18-E6 protein, the test can miss some CIN2/3+ lesions caused by other high-risk HPV types.Cancer Prevention Department, Center for the Researcher Support and Pathology Department of the Barretos Cancer Hospital. This study was supported by CNPq 573799/2008-3 and FAPESP 2008/57889-1info:eu-repo/semantics/publishedVersio

    The ThomX project status

    Get PDF
    Work supported by the French Agence Nationale de la recherche as part of the program EQUIPEX under reference ANR-10-EQPX-51, the Ile de France region, CNRS-IN2P3 and Université Paris Sud XI - http://accelconf.web.cern.ch/AccelConf/IPAC2014/papers/wepro052.pdfA collaboration of seven research institutes and an industry has been set up for the ThomX project, a compact Compton Backscattering Source (CBS) based in Orsay - France. After a period of study and definition of the machine performance, a full description of all the systems has been provided. The infrastructure work has been started and the main systems are in the call for tender phase. In this paper we will illustrate the definitive machine parameters and components characteristics. We will also update the results of the different technical and experimental activities on optical resonators, RF power supplies and on the electron gun
    • 

    corecore