1,725 research outputs found
Template-Stripped Multifunctional Wedge and Pyramid Arrays for Magnetic Nanofocusing and Optical Sensing
We present large-scale reproducible
fabrication of multifunctional ultrasharp metallic structures on planar
substrates with capabilities including magnetic field nanofocusing
and plasmonic sensing. Objects with sharp tips such as wedges and
pyramids made with noble metals have been extensively used for enhancing
local electric fields via the lightning-rod effect or plasmonic nanofocusing.
However, analogous nanofocusing of magnetic fields using sharp tips
made with magnetic materials has not been widely realized. Reproducible
fabrication of sharp tips with magnetic as well as noble metal layers
on planar substrates can enable straightforward application of their
material and shape-derived functionalities. We use a template-stripping
method to produce plasmonic-shell-coated nickel wedge and pyramid
arrays at the wafer-scale with tip radius of curvature close to 10
nm. We further explore the magnetic nanofocusing capabilities of these
ultrasharp substrates, deriving analytical formulas and comparing
the results with computer simulations. These structures exhibit nanoscale
spatial control over the trapping of magnetic microbeads and nanoparticles
in solution. Additionally, enhanced optical sensing of analytes by
these plasmonic-shell-coated substrates is demonstrated using surface-enhanced
Raman spectroscopy. These methods can guide the design and fabrication
of novel devices with applications including nanoparticle manipulation,
biosensing, and magnetoplasmonics
Association of Depressive Symptoms With Postoperative Delirium and CSF Biomarkers for Alzheimer's Disease Among Hip Fracture Patients
OBJECTIVES: While there is growing evidence of an association between depressive symptoms and postoperative delirium, the underlying pathophysiological mechanisms remain unknown. The goal of this study was to explore the association between depression and postoperative delirium in hip fracture patients, and to examine Alzheimer's disease (AD) pathology as a potential underlying mechanism linking depressive symptoms and delirium. METHODS: Patients 65 years old or older (N = 199) who were undergoing hip fracture repair and enrolled in the study "A Strategy to Reduce the Incidence of Postoperative Delirium in Elderly Patients" completed the 15-item Geriatric Depression Scale (GDS-15) preoperatively. Cerebrospinal fluid (CSF) was obtained during spinal anesthesia and assayed for amyloid-beta (Aβ) 40, 42, total tau (t-tau), and phosphorylated tau (p-tau)181. RESULTS: For every one point increase in GDS-15, there was a 13% increase in odds of postoperative delirium, adjusted for baseline cognition (MMSE), age, sex, race, education and CSF AD biomarkers (OR = 1.13, 95%CI = 1.02-1.25). Both CSF Aꞵ42/t-tau (β = -1.52, 95%CI = -2.1 to -0.05) and Aꞵ42/p-tau181 (β = -0.29, 95%CI = -0.48 to -0.09) were inversely associated with higher GDS-15 scores, where lower ratios indicate greater AD pathology. In an analysis to identify the strongest predictors of delirium out of 18 variables, GDS-15 had the highest classification accuracy for postoperative delirium and was a stronger predictor of delirium than both cognition and AD biomarkers. CONCLUSIONS: In older adults undergoing hip fracture repair, depressive symptoms were associated with underlying AD pathology and postoperative delirium. Mild baseline depressive symptoms were the strongest predictor of postoperative delirium, and may represent a dementia prodrome
Micro-Electro-Mechanical-Systems (MEMS) and Fluid Flows
The micromachining technology that emerged in the late 1980s can provide micron-sized sensors and actuators. These micro transducers are able to be integrated with signal conditioning and processing circuitry to form micro-electro-mechanical-systems (MEMS) that can perform real-time distributed control. This capability opens up a new territory for flow control research. On the other hand, surface effects dominate the fluid flowing through these miniature mechanical devices because of the large surface-to-volume ratio in micron-scale configurations. We need to reexamine the surface forces in the momentum equation. Owing to their smallness, gas flows experience large Knudsen numbers, and therefore boundary conditions need to be modified. Besides being an enabling technology, MEMS also provide many challenges for fundamental flow-science research
Recommended from our members
Atlantic Ocean influence on a shift in European climate in the 1990s
European climate exhibits variability on a wide range of timescales. Understanding the nature and drivers of this variability is an essential step in developing robust climate predictions and risk assessments. The Atlantic Ocean has been suggested as an important driver of variability in European climate on decadal timescales1, but the importance of this influence in recent decades has been unclear, partly because of difficulties in separating the influence of the Atlantic Ocean from other contributions, for example, from the tropical Pacific Ocean and the stratosphere. Here we analyse four data sets derived from observations to show that, during the 1990s, there was a substantial shift in European climate towards a pattern characterized by anomalously wet summers in northern Europe, and hot, dry, summers in southern Europe, with related shifts in spring and autumn. These changes in climate coincided with a substantial warming of the North Atlantic Ocean, towards a state last seen in the 1950s. The patterns of European climate change in the 1990s are consistent with earlier changes attributed to the influence of the North Atlantic Ocean, and provide compelling evidence that the Atlantic Ocean was the key driver. Our results suggest that the recent pattern of anomalies in European climate will persist as long as the North Atlantic Ocean remains anomalously warm
A False Start in the Race Against Doping in Sport: Concerns With Cycling’s Biological Passport
Professional cycling has suffered from a number of doping scandals. The sport’s governing bodies have responded by implementing an aggressive new antidoping program known as the biological passport. Cycling’s biological passport marks a departure from traditional antidoping efforts, which have focused on directly detecting prohibited substances in a cyclist’s system. Instead, the biological passport tracks biological variables in a cyclist’s blood and urine over time, monitoring for fluctuations that are thought to indirectly reveal the effects of doping. Although this method of indirect detection is promising, it also raises serious legal and scientific concerns. Since its introduction, the cycling community has debated the reliability of indirect biological-passport evidence and the clarity, consistency, and transparency of its use in proving doping violations. Such uncertainty undermines the legitimacy of finding cyclists guilty of doping based on this indirect evidence alone. Antidoping authorities should address these important concerns before continuing to pursue doping sanctions against cyclists solely on the basis of their biological passports
Nanoparticles of Block Ionomer Complexes from Double Hydrophilic Poly(acrylic acid)-b-poly(ethylene oxide)-b-poly(acrylic acid) Triblock Copolymer and Oppositely Charged Surfactant
The novel water-dispersible nanoparticles from the double hydrophilic poly(acrylic acid)-b-poly(ethylene oxide)-b-poly(acrylic acid) (PAA-b-PEO-b-PAA) triblock copolymer and oppositely charged surfactant dodecyltrimethyl ammonium bromide (DTAB) were prepared by mixing the individual aqueous solutions. The structure of the nanoparticles was investigated as a function of the degree of neutralization (DN) by turbidimetry, dynamic light scattering (DSL),ζ-potential measurement, and atomic force microscope (AFM). The neutralization of the anionic PAA blocks with cationic DTAB accompanied with the hydrophobic interaction of alkyl tails of DTAB led to formation of core–shell nanoparticles with the core of the DTAB neutralized PAA blocks and the shell of the looped PEO blocks. The water-dispersible nanoparticles with negative ζ-potential were obtained over the DN range from 0.4 to 2.0 and their sizes depended on the DN. The looped PEO blocks hindered the further neutralization of the PAA blocks with cationic DTAB, resulting in existence of some negative charged PAA-b-PEO-b-PAA backbones even when DN > 1.0. The spherical and ellipsoidal nature of these nanoparticles was observed with AFM
Recommended from our members
The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length
Purpose
The purpose of this study was to assess the effects of incorporating individual ocular biometry measures of corneal curvature, refractive error, and axial length on scan length obtained using Spectralis spectral domain optical coherence tomography (SD-OCT).
Methods
Two SD-OCT scans were acquired for 50 eyes of 50 healthy participants, first using the Spectralis default keratometry (K) setting followed by incorporating individual mean-K values. Resulting scan lengths were compared to predicted scan lengths produced by image simulation software, based on individual ocular biometry measures including axial length.
Results
Axial length varied from 21.41 to 29.04 mm. Spectralis SD-OCT scan lengths obtained with default-K ranged from 5.7 to 7.3 mm, and with mean-K from 5.6 to 7.6 mm. We report a stronger correlation of simulated scan lengths incorporating the subject’s mean-K value (ρ = 0.926, P < 0.0005) compared to Spectralis default settings (ρ = 0.663, P < 0.0005).
Conclusions
Ocular magnification appears to be better accounted for when individual mean-K values are incorporated into Spectralis SD-OCT scan acquisition versus using the device’s default-K setting. This must be considered when taking area measurements and lateral measurements parallel to the retinal surface
Electrospun poly(vinyl alcohol) nanofibers: effects of degree of hydrolysis and enhanced water stability
ArticlePOLYMER JOURNAL. 42(3):273-276 (2010)journal articl
Acute paranoid psychosis as sole clinical presentation of hepatic artery thrombosis after living donor liver transplantation
<p>Abstract</p> <p>Background</p> <p>Hepatic artery thrombosis is a devastating complication after orthotopic liver transplantation often requiring revascularization or re-transplantation. It is associated with considerably increased morbidity and mortality. Acute cognitive dysfunction such as delirium or acute psychosis may occur after major surgery and may be associated with the advent of surgical complications.</p> <p>Case presentation</p> <p>Here we describe a case of hepatic artery thrombosis after living-donor liver transplantation which was not preceded by signs of liver failure but rather by an episode of acute psychosis. After re-transplantation the patient recovered without sequelae.</p> <p>Conclusion</p> <p>This case highlights the need to remain cautious when psychiatric disorders occur in patients after liver transplantation. The diagnostic procedures should not be restricted to medical or neurological causes of psychosis alone but should also focus vascular complications related to orthotopic liver transplantation.</p
- …