1,220 research outputs found

    Radar cross calibration investigation TAMU radar polarimeter calibration measurements

    Get PDF
    A short pulse, 20 MHz bandwidth, three frequency radar polarimeter system (RPS) operates at center frequencies of 10.003 GHz, 4.75 GHz, and 1.6 GHz and utilizes dual polarized transmit and receive antennas for each frequency. The basic lay-out of the RPS is different from other truck mounted systems in that it uses a pulse compression IF section common to all three RF heads. Separate transmit and receive antennas are used to improve the cross-polarization isolation at each particular frequency. The receive is a digitally controlled gain modulated subsystem and is interfaced directly with a microprocesser computer for control and data manipulation. Antenna focusing distance, focusing each antenna pair, rf head stability, and polarization characteristics of RPS antennas are discussed. Platform and data acquisition procedures are described

    Analysis of the Saccharomyces cerevisiae proteome with PeptideAtlas

    Get PDF
    We present the Saccharomyces cerevisiae PeptideAtlas composed from 47 diverse experiments and 4.9 million tandem mass spectra. The observed peptides align to 61% of Saccharomyces Genome Database (SGD) open reading frames (ORFs), 49% of the uncharacterized SGD ORFs, 54% of S. cerevisiae ORFs with a Gene Ontology annotation of 'molecular function unknown', and 76% of ORFs with Gene names. We highlight the use of this resource for data mining, construction of high quality lists for targeted proteomics, validation of proteins, and software development

    Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    Get PDF
    Objective. To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.Methods. Thirteen observers examined nine patients with RA and one healthy individual in two rounds independently and blindly of each other. Each round consisted of two consecutive examinations, an anatomy-based examination and a free examination according to personal preferences. The following tendons were evaluated: wrist extensor compartments 2, 4 and 6, finger flexor tendons 3 and 4 at MCP level, tibialis posterior tendon and both peronei tendons. Overall, positive and negative agreements and \u3ba-values for greyscale (GS) tenosynovitis, peritendinous power Doppler (PPD) signal, intratendinous power Doppler (IPD) signal and GS tendon damage were calculated.Results. Intraobserver \u3ba-value ranges were 0.53-0.55 (P < 0.0005) for GS tenosynovitis, 0.61-0.64 (P < 0.0005) for PPD signal, 0.65-0.66 (P < 0.0005) for IPD signal and 0.44-0.53 (P < 0.0005) for GS tendon damage. For interobserver reliability, substantial overall agreement ranged from 80 to 89% for GS tenosynovitis, 97 to 100% for PPD signal, 97 to 100% for IPD signal and 97 to 100% for GS tendon damage. Results were independent of scanning technique.Conclusion. Intraobserver reliability for tenosynovitis and tendon damage varied from moderate for GS to good for PD. Overall interobserver reliability for tenosynovitis and tendon damage was excellent both for GS and PD. This qualitative scoring system may serve as the first step to a semi-quantitative score for tendon pathology. \ua9 The Author 2012. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved

    Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    Get PDF
    Objective. To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.Methods. Thirteen observers examined nine patients with RA and one healthy individual in two rounds independently and blindly of each other. Each round consisted of two consecutive examinations, an anatomy-based examination and a free examination according to personal preferences. The following tendons were evaluated: wrist extensor compartments 2, 4 and 6, finger flexor tendons 3 and 4 at MCP level, tibialis posterior tendon and both peronei tendons. Overall, positive and negative agreements and Îș-values for greyscale (GS) tenosynovitis, peritendinous power Doppler (PPD) signal, intratendinous power Doppler (IPD) signal and GS tendon damage were calculated.Results. Intraobserver Îș-value ranges were 0.53-0.55 (P < 0.0005) for GS tenosynovitis, 0.61-0.64 (P < 0.0005) for PPD signal, 0.65-0.66 (P < 0.0005) for IPD signal and 0.44-0.53 (P < 0.0005) for GS tendon damage. For interobserver reliability, substantial overall agreement ranged from 80 to 89% for GS tenosynovitis, 97 to 100% for PPD signal, 97 to 100% for IPD signal and 97 to 100% for GS tendon damage. Results were independent of scanning technique.Conclusion. Intraobserver reliability for tenosynovitis and tendon damage varied from moderate for GS to good for PD. Overall interobserver reliability for tenosynovitis and tendon damage was excellent both for GS and PD. This qualitative scoring system may serve as the first step to a semi-quantitative score for tendon pathology. © The Author 2012. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved

    Morphological and Electrochemical Properties of Crystalline Praseodymium Oxide Nanorods

    Get PDF
    Highly crystalline Pr6O11 nanorods were prepared by a simple precipitation method of triethylamine complex at 500°C. Synthesized Pr6O11 nanorods were uniformly grown with the diameter of 12–15 nm and the length of 100–150 nm without any impurities of unstable PrO2 phase. The Pr6O11 nanorod electrodes attained a high electrical conductivity of 0.954 Scm−1 with low activation energy of 0.594 eV at 850°C. The electrochemical impedance study showed that the resistance of electrode was significantly decreased at high temperature, which resulted from its high conductivity and low activation energy. The reduced impedance and high electrical conductivity of Pr6O11 nanorod electrodes are attributed to the reduction of grain boundaries and high space charge width

    One-pot synthesis and AFM imaging of a triangular aramide macrocycle

    Get PDF
    Macrocyclizations in exceptionally good yields were observed during the self-condensation of N-benzylated phenyl p-aminobenzoates in the presence of LiHMDS to yield three-membered cyclic aramides that adopt a triangular shape. An ortho-alkyloxy side chain on the N-benzyl protecting group is necessary for the macrocyclization to occur. Linear polymers are formed exclusively in the absence of this Li-chelating group. A model that explains the lack of formation of other cyclic congeners and the demand for an N-(o-alkoxybenzyl) protecting group is provided on the basis of DFT calculations. High-resolution AFM imaging of the prepared molecular triangles on a calcite(10.4) surface shows individual molecules arranged in groups of four due to strong surface templating effects and hydrogen bonding between the molecular triangles

    The 2017 EULAR standardised procedures for ultrasound imaging in rheumatology

    Get PDF
    BACKGROUND: In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines.OBJECTIVES: To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology.METHODS: The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures).RESULTS: Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts.CONCLUSIONS: This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology

    Ultrasound in the evaluation of enthesitis: status and perspectives

    Get PDF
    Introduction: An increasing number of studies have applied ultrasound to the evaluation of entheses in spondyloarthritis patients. However, no clear agreement exists on the definition of enthesitis, on the number and choice of entheses to examine and on ultrasound technique, which may all affect the results of the examination. The objectives of this study were to first determine the level of homogeneity in the ultrasound definitions for the principal lesions of enthesitis in the published literature and second, to evaluate the metric properties of ultrasound for detecting enthesitis according to the OMERACT filter. Methods: Search was performed in PUBMED and EMBASE. Both grey-scale and Doppler definitions of enthesitis, including describing features of enthesitis, were collected and metrological qualities of studies were assessed. Results: After selection, 48 articles were analyzed. The definition of ultrasound enthesitis and elementary features varied among authors. Grey-scale enthesitis was characterized by increasing thickness (94% of studies), hypoechogenicity (83%), enthesophytes (69%), erosions (67%), calcifications (52%), associated bursitis (46%) and cortical irregularities (29%). Only 46% of studies reported the use of Doppler. High discrepancies were observed on frequency, type of probe and Doppler mode used. Face and content validity were the most frequently evaluated criteria (43%) followed by reliability (29%) and responsiveness (19%). Conclusions: Ultrasound has evidence to support face, content validity and reliability for the evaluation of enthesitis, though there is a lack of well-reported methodology in most of the studies. Consensus on elementary lesions and standardization of exam is needed to determine the ultrasound definition of enthesitis in grey-scale and in Doppler for future applications.15 page(s
    • 

    corecore