62 research outputs found

    Ligand-Specific Factors Influencing GLP-1 Receptor Post-Endocytic Trafficking and Degradation in Pancreatic Beta Cells.

    Get PDF
    The glucagon-like peptide-1 receptor (GLP-1R) is an important regulator of blood glucose homeostasis. Ligand-specific differences in membrane trafficking of the GLP-1R influence its signalling properties and therapeutic potential in type 2 diabetes. Here, we have evaluated how different factors combine to control the post-endocytic trafficking of GLP-1R to recycling versus degradative pathways. Experiments were performed in primary islet cells, INS-1 832/3 clonal beta cells and HEK293 cells, using biorthogonal labelling of GLP-1R to determine its localisation and degradation after treatment with GLP-1, exendin-4 and several further GLP-1R agonist peptides. We also characterised the effect of a rare GLP1R coding variant, T149M, and the role of endosomal peptidase endothelin-converting enzyme-1 (ECE-1), in GLP1R trafficking. Our data reveal how treatment with GLP-1 versus exendin-4 is associated with preferential GLP-1R targeting towards a recycling pathway. GLP-1, but not exendin-4, is a substrate for ECE-1, and the resultant propensity to intra-endosomal degradation, in conjunction with differences in binding affinity, contributes to alterations in GLP-1R trafficking behaviours and degradation. The T149M GLP-1R variant shows reduced signalling and internalisation responses, which is likely to be due to disruption of the cytoplasmic region that couples to intracellular effectors. These observations provide insights into how ligand- and genotype-specific factors can influence GLP-1R trafficking

    Using Soft Polymer Template Engineering of Mesoporous TiO2 Scaffolds to Increase Perovskite Grain Size and Solar Cell Efficiency

    Get PDF
    The mesoporous (meso)-TiO2 layer is a key component of high-efficiency perovskite solar cells (PSCs). Herein, pore size controllable meso-TiO2 layers are prepared using spin coating of commercial TiO2 nanoparticle (NP) paste with added soft polymer templates (SPT) followed by removal of the SPT at 500 °C. The SPTs consist of swollen crosslinked polymer colloids (microgels, MGs) or a commercial linear polymer (denoted as LIN). The MGs and LIN were comprised of the same polymer, which was poly(N-isopropylacrylamide) (PNIPAm). Large (L-MG) and small (S-MG) MG SPTs were employed to study the effect of the template size. The SPT approach enabled pore size engineering in one deposition step. The SPT/TiO2 nanoparticle films had pore sizes > 100 nm, whereas the average pore size was 37 nm for the control meso-TiO2 scaffold. The largest pore sizes were obtained using L-MG. SPT engineering increased the perovskite grain size in the same order as the SPT sizes: LIN < S-MG < L-MG and these grain sizes were larger than those obtained using the control. The power conversion efficiencies (PCEs) of the SPT/TiO2 devices were ∼20% higher than that for the control meso-TiO2 device and the PCE of the champion S-MG device was 18.8%. The PCE improvement is due to the increased grain size and more effective light harvesting of the SPT devices. The increased grain size was also responsible for the improved stability of the SPT/TiO2 devices. The SPT method used here is simple, scalable, and versatile and should also apply to other PSCs

    Hypoglycemia in Non-Diabetic In-Patients: Clinical or Criminal?

    Get PDF
    BACKGROUND AND AIM: We wished to establish the frequency of unexpected hypoglycemia observed in non diabetic patients outside the intensive care unit and to determine if they have a plausible clinical explanation. METHODS: We analysed data for 2010 from three distinct sources to identify non diabetic hypoglycaemic patients: bedside and laboratory blood glucose measurements; medication records for those treatments (high-strength glucose solution and glucagon) commonly given to reverse hypoglycemia; and diagnostic codes for hypoglycemia. We excluded from the denominator admissions of patients with a diagnosis of diabetes or prescribed diabetic medication. Case notes of patients identified were reviewed. We used capture-recapture methods to establish the likely frequency of hypoglycemia in non-diabetic in-patients outside intensive care unit at different cut-off points for hypoglycemia. We also recorded co-morbidities that might have given rise to hypoglycemia. RESULTS: Among the 37,898 admissions, the triggers identified 71 hypoglycaemic episodes at a cut-off of 3.3 mmol/l. Estimated frequency at 3.3 mmol/l was 50(CI 33-93), at 3.0 mmol/l, 36(CI 24-64), at 2.7 mmol/l, 13(CI 11-19), at 2.5 mmol/l, 11(CI 9-15) and at 2.2 mmol/l, 8(CI 7-11) per 10,000 admissions. Admissions of patients aged above 65 years were approximately 50% more likely to have an episode of hypoglycemia. Most were associated with important co-morbidities. CONCLUSION: Significant non-diabetic hypoglycemia in hospital in-patients (at or below 2.7 mmol/l) outside critical care is rare. It is sufficiently rare for occurrences to merit case-note review and diagnostic blood tests, unless an obvious explanation is found

    Postoperative outcomes in oesophagectomy with trainee involvement

    Get PDF
    BACKGROUND: The complexity of oesophageal surgery and the significant risk of morbidity necessitates that oesophagectomy is predominantly performed by a consultant surgeon, or a senior trainee under their supervision. The aim of this study was to determine the impact of trainee involvement in oesophagectomy on postoperative outcomes in an international multicentre setting. METHODS: Data from the multicentre Oesophago-Gastric Anastomosis Study Group (OGAA) cohort study were analysed, which comprised prospectively collected data from patients undergoing oesophagectomy for oesophageal cancer between April 2018 and December 2018. Procedures were grouped by the level of trainee involvement, and univariable and multivariable analyses were performed to compare patient outcomes across groups. RESULTS: Of 2232 oesophagectomies from 137 centres in 41 countries, trainees were involved in 29.1 per cent of them (n = 650), performing only the abdominal phase in 230, only the chest and/or neck phases in 130, and all phases in 315 procedures. For procedures with a chest anastomosis, those with trainee involvement had similar 90-day mortality, complication and reoperation rates to consultant-performed oesophagectomies (P = 0.451, P = 0.318, and P = 0.382, respectively), while anastomotic leak rates were significantly lower in the trainee groups (P = 0.030). Procedures with a neck anastomosis had equivalent complication, anastomotic leak, and reoperation rates (P = 0.150, P = 0.430, and P = 0.632, respectively) in trainee-involved versus consultant-performed oesophagectomies, with significantly lower 90-day mortality in the trainee groups (P = 0.005). CONCLUSION: Trainee involvement was not found to be associated with significantly inferior postoperative outcomes for selected patients undergoing oesophagectomy. The results support continued supervised trainee involvement in oesophageal cancer surgery

    Time to endoscopy for acute upper gastrointestinal bleeding: results from a prospective multicentre trainee-led audit

    Get PDF
    Background: Endoscopy within 24 hours of admission (early endoscopy) is a quality standard in acute upper gastrointestinal bleeding (AUGIB). We aimed to audit time to endoscopy outcomes and identify factors affecting delayed endoscopy (>24h of admission).Methods: This prospective multicentre audit enrolled patients admitted with AUGIB who underwent inpatient endoscopy between Nov-Dec 2017. Analyses were performed to identify factorsassociated with delayed endoscopy, and to compare patient outcomes, including length of stay and mortality rates, between early and delayed endoscopy groups.Results: Across 348 patients from 20 centres, the median time to endoscopy was 21.2h (IQR 12.0- 35.7), comprising median admission to referral and referral to endoscopy times of 8.1h (IQR 3.7- 18.1) and 6.7h (IQR 3.0-23.1) respectively. Early endoscopy was achieved in 58.9%, although this varied by centre (range: 31.0% - 87.5%, p=0.002). On multivariable analysis, lower Glasgow-Blatchford score, delayed referral, admissions between 7am-7pm or via the Emergency Department were independent predictors of delayed endoscopy. Early endoscopy was associated with reduced length of stay (median difference 1d; p= 0.004), but not 30-day mortality (p=0.344).Conclusions: The majority of centres did not meet national standards for time to endoscopy. Strategic initiatives involving acute care services may be necessary to improve this outcome

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals &lt;1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    The 30-15 intermittent fitness test: can it predict outcomes in field tests of anaerobic performance?

    No full text
    This study determined whether a composite assessment of intermittent fitness could be used to quantify performance in several anaerobic tasks. Fifty-two male recreational athletes (age: 24.3 ± 4.4 years; body mass: 85.1 ± 12.2 kg; height: 180.5 ± 7.0 cm) were recruited from various team sports. Participants completed a battery of field tests to assess sprinting speed (40-m sprint), acceleration ability (10-m sprint), change of direction speed (505 test), anaerobic capacity (300-m shuttle), lower-body power (vertical jump), and repeated-sprint ability and the 30-15 Intermittent Fitness Test to determine the velocity of intermittent fitness (VIFT). Relationships between anaerobic tests and VIFT were quantified via Pearson product-moment correlations, and a 2-predictor model multiple linear regression estimated the predictive relationships between the exercise tests and the VIFT. Multiple linear regression showed that VIFT significantly predicted 56, 51, 44, 36, 12, and 1% of the variance in the 300-m shuttle, repeated sprint, 505- and 40-m sprint, vertical jump, and 10-m sprint tests, respectively. The 2-predictor model determined the 300-m shuttle, and repeated-sprint performance accounted for 67% of the variance in VIFT. These findings highlight that various anaerobic characteristics contribute to the intermittent fitness qualities that are quantified through VIFT. More specifically, these data indicate that VIFT is useful for tracking performance in tasks largely determined by anaerobic capacity, but may not be a good predictor of brief all-out sprinting and jumping efforts
    • …
    corecore