461 research outputs found

    Quantitative analysis of bone reactions to relative motions at implant-bone interfaces

    Get PDF
    Connective soft tissues at the interface between implants and bone, such as in human joint replacements, can endanger the stability of the implant fixation. The potential of an implant to generate interface bone resorption and form soft tissue depends on many variables, including mechanical ones. These mechanical factors can be expressed in terms of relative motions between bone and implant at the interface or deformation of the interfacial material.\ud \ud The purpose of this investigation was to determine if interface debonding and subsequent relative interface motions can be responsible for interface degradation and soft tissue interposition as seen in experiments and clinical results. A finite element computer program was augmented with a mathematical description of interface debonding, dependent on interface stress criteria, and soft tissue interface interposition, dependent on relative interface motions. Three simplified models of orthopaedic implants were constructed: a cortical bone screw for fracture fixation plates, a femoral resurfacing prosthesis and a straight stem model, cemented in a bone. The predicted computer configurations were compared with clinical observations. The computer results showed how interface disruption and fibrous tissue interposition interrelate and possibly enhance each other, whereby a progressive development of the soft tissue layer can occur.\ud \ud Around the cortical bone screw, the predicted resorption patterns were relatively large directly under the screw head and showed a pivot point in the opposite cortex. The resurfacing cup model predicted some fibrous tissue formation under the medial and lateral cup rim, whereby the medial layer developed first because of higher initial interface stresses. The straight stem model predicted initial interface failure at the proximal parts. After proximal resorption and fibrous tissue interposition, the medial interface was completely disrupted and developed an interface layer. The distal and mid lateral side maintained within the strength criterion.\ud \ud Although the applied models were relatively simple, the results showed reasonable qualitative agreement with resorption patterns found in clinical studies concerning bone screws and the resurfacing cup. The hypothesis that interface debonding and subsequent relative (micro)motions could be responsible for bone resorption and fibrous tissue propagation is thereby sustained by the results

    Sensitivity analysis of periprosthetic healing to cell migration, growth factor and post-operative gap using a mechanobiological model

    Get PDF
    A theoretical rationale, which could help in the investigation of mechanobiological factors affecting periprosthetic tissue healing, is still an open problem. We used a parametric sensitivity analysis to extend a theoretical model based on reactive transport and computational cell biology. The numerical experimentation involved the drill hole, the haptotactic and chemotactic migrations, and the initial concentration of an anabolic growth factor. Output measure was the mineral fraction in tissue surrounding a polymethymethacrylate (PMMA) canine implant (stable loaded implant, non-critical gap). Increasing growth factor concentration increased structural matrix synthesis. A cell adhesion gradient resulted in heterogeneous bone distribution and a growth factor gradient resulted in homogeneous bone distribution in the gap. This could explain the radial variation of bone density from the implant surface to the drill hole, indicating less secure fixation. This study helps to understand the relative importance of various host and clinical factors influencing bone distribution and resulting implant fixation

    Comparison of flanged and unflanged acetabular cup design: An experimental study using ceramic and cadaveric acetabuli

    Get PDF
    Background and purpose Adequate depth of cement penetration and cement mantle thickness is important for the durability of cemented cups. A flanged cup, as opposed to unflanged, has been suggested to give a more uniform cement mantle and superior cement pressurization, thus improving the depth of cement penetration. This hypothesis was tested experimentally. Materials and methods The same cup design with and without flange (both without cement spacers) was investigated regarding intraacetabular pressure, cement mantle thickness, and depth of cement penetration. With machine control, the cups were inserted into open-pore ceramic acetabular models (10 flanged, 10 unflanged) and into paired cadaver acetabuli (10 flanged, 10 unflanged) with prior pressurization of the cement. Results No differences in intraacetabular pressures during cup insertion were found, but unflanged cups tended to migrate more towards the acetabular pole. Flanged cups resulted in thicker cement mantles because of less bottoming out, whereas no differences in cement penetration into the bone were observed. Interpretation Flanged cups do not generate higher cementation pressure or better cement penetration than unflanged cups. A possible advantage of the flange, however, may be to protect the cup from bottoming out, and there is possibly better closure of the periphery around the cup, sealing off the cement-bone interface

    What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    Get PDF
    Background and purpose An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultra-sound as compared with MR arthrography

    Effect of early supervised progressive resistance training compared to unsupervised home-based exercise after fast-track total hip replacement applied to patients with preoperative functional limitations. A single-blinded randomised controlled trial

    Get PDF
    SummaryObjectiveTo examine if 2 weekly sessions of supervised progressive resistance training (PRT) in combination with 5 weekly sessions of unsupervised home-based exercise is more effective than 7 weekly sessions of unsupervised home-based exercise in improving leg-extension power of the operated leg 10 weeks after total hip replacement (THR) in patients with lower pre-operative function.MethodA total of 73 patients scheduled for THR were randomised (1:1) to intervention group (IG, home based exercise 5 days/week and PRT 2 days/week) or control group (CG, home based exercise 7 days/week). The primary endpoint was change in leg extension power at 10 week follow up. Secondary outcomes were isometric hip muscle strength, sit-to-stand test, stair climb test, 20 m walking speed and patient-reported outcome (HOOS).ResultsSixty-two completed the trial (85%). Leg extension power increased from baseline to the 10 week follow up in both groups; mean [95% CI] IG: 0.29 [0.13; 0.45] and CG: 0.26 [0.10; 0.42] W/kg, with no between-group difference (primary outcome) (P = 0.79). Maximal walking speed (P = 0.008) and stair climb performance (P = 0.04) improved more in the IG compared to CG, no other between-group differences existed.ConclusionsIn this trial, supervised PRT twice a week in addition to 5 weekly sessions of unsupervised exercise for 10 weeks was not superior to 7 weekly sessions of unsupervised home-based exercise for 10 weeks in improving the primary outcome, leg-extension power of the operated leg, at the primary endpoint 10 weeks after surgery in THR patients with lower pre-operative function.Trial registration: NCT01214954

    Validation of suitable house keeping genes for hypoxia-cultured human chondrocytes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hypoxic culturing of chondrocytes is gaining increasing interest in cartilage research. Culturing of chondrocytes under low oxygen tension has shown several advantages, among them increased synthesis of extracellular matrix and increased redifferentiation of dedifferentiated chondrocytes. Quantitative gene expression analyses such as quantitative real-time PCR (qRT-PCR) are powerful tools in the investigation of underlying mechanisms of cell behavior and are used routinely for differentiation and phenotype assays. However, the genes used for normalization in normoxic cell-cultures might not be suitable in the hypoxic environment. The objective of this study was to determine hypoxia-stable housekeeping genes (HKG) for quantitative real-time PCR (qRT-PCR) in human chondrocytes cultured in 21%, 5% and 1% oxygen by geNorm and NormFinder analyses.</p> <p>Results</p> <p>The chondrocytic response to the hypoxic challange was validated by a significant increase in expression of the hypoxia-inducible gene ankyrin repeat 37 as well as SOX9 in hypoxia. When cultured on the 3-dimentional (3D) scaffold TATA-binding protein (TBP) exhibited the highest expression stability with NormFinder while Ribosomal protein L13a (RPL13A) and beta2-microglobulin (B2M) were the most stable using geNorm analysis. In monolayer RPL13A were the most stable gene using NormFinder, while geNorm assessed RPL13A and human RNA polymerase II (RPII) as most stable. When examining the combination of (3D) culturing and monolayer RPL13A and B2M showed the highest expression stability from geNorm analysis while RPL13A also showed the highest expression stability using NormFinder. Often used HKG such as beta actin (ACTB) and glyceraldehyde-3-phosphate dehydrogenase (GAPDH) were the most unstable genes investigated in all comparisons. The pairwise variations for the two most stable HKG in each group were all below the cut-off value of 0.15, suggesting that the two most stable HKG from geNorm analysis would be sufficient for qRT-PCR.</p> <p>Conclusion</p> <p>All data combined we recommend RPL13A, B2M and RPII as the best choice for qRT-PCR analyses when comparing normoxic and hypoxic cultured human chondrocytes although other genes might also be suitable. However, the matching of HKG to target genes by means of a thorough investigation of the stability in each study would always be preferable.</p

    A phonetically-based phoneme analysis of the Danish consonant system. (Marie Skłodowska-Curie Action. Project: What makes the Danish sound system so difficult for non-native learners? Acronym: LxDP’)

    Get PDF
    The traditional phoneme analysis of the Danish consonant inventory links onset and coda consonants on the basis of historical alternations and morphologically conditioned alternations within a small subset of the Danish lexicon. This traditional analysis proposes a system resulting in a large number of neutralizations that cannot be dissolved, and in which allophones of the same phoneme lack shared phonetic content. We argue that the system proposed by the traditional analysis is impossible to learn from the language input, which renders the analysis an implausible description of the Danish consonant system. On the basis of theoretical discussions, we offer an alternative phoneme analysis, which we believe to be learnable from the data available in the language input. Our analysis is based on insights from Natural Phonology and Bidirectional Phonetics and Phonology. We propose a system without undissolvable neutralizations, with shared phonetic content between allophones of the same phoneme, and without the need to rely on alternations that children are unlikely to learn in early childhood.894936Theoretical and Experimental Linguistic
    corecore