5,897 research outputs found

    Corneal relaxation time estimation as a function of tear oxygen tension in human cornea during contact lens wear

    Full text link
    [EN] The purpose is to estimate the oxygen diffusion coefficient and the relaxation time of the cornea with respect to the oxygen tension at the cornea-tears interface. Both findings are discussed. From the experimental data provided by Bonanno et al., the oxygen tension measurements in vivo for human cornea-tears-contact lens (CL), the relaxation time of the cornea, and their oxygen diffusion coefficient were obtained by numerical calculation using the Monod-kinetic model. Our results, considering the relaxation time of the cornea, observe a different behavior. At the time less than 8 s, the oxygen diffusivity process is upper-diffusive, and for the relaxation time greater than 8 s, the oxygen diffusivity process is lower-diffusive. Both cases depend on the partial pressure of oxygen at the entrance of the cornea. The oxygen tension distribution in the cornea-tears interface is separated into two different zones: one for conventional hydrogels, which is located between 6 and 75 mmHg, with a relaxation time included between 8 and 19 s, and the other zone for silicone hydrogel CLs, which is located at high oxygen tension, between 95 and 140 mmHg, with a relaxation time in the interval of 1.5-8 s. It is found that in each zone, the diffusion coefficient varies linearly with the oxygen concentration, presenting a discontinuity in the transition of 8 s. This could be interpreted as an aerobic-to-anaerobic transition. We attribute this behavior to the coupling formalism between oxygen diffusion and biochemical reactions to produce adenosine triphosphate.Contract grant sponsor: Dirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México; contract grant number: UNAM-DGAPA-PAPIIT projects IG 100618 and IN-114818 Contract grant sponsor: Secretaría de Estado de Investigación, Desarrollo e Innovación; contract grant number: ENE/2015-69203-RDel Castillo, LF.; Ramírez-Calderón, JG.; Del Castillo, RM.; Aguilella-Arzo, M.; Compañ Moreno, V. (2020). Corneal relaxation time estimation as a function of tear oxygen tension in human cornea during contact lens wear. Journal of Biomedical Materials Research Part B Applied Biomaterials. 108(1):14-21. https://doi.org/10.1002/jbm.b.34360S14211081Freeman, R. D. (1972). Oxygen consumption by the component layers of the cornea. The Journal of Physiology, 225(1), 15-32. doi:10.1113/jphysiol.1972.sp009927CHALMERS, R. L., McNALLY, J. J., SCHEIN, O. D., KATZ, J., TIELSCH, J. M., ALFONSO, E., … SHOVLIN, J. (2007). Risk Factors for Corneal Infiltrates with Continuous Wear of Contact Lenses. Optometry and Vision Science, 84(7), 573-579. doi:10.1097/opx.0b013e3180dc9a12Schein, O. D., McNally, J. J., Katz, J., Chalmers, R. L., Tielsch, J. M., Alfonso, E., … Shovlin, J. (2005). The Incidence of Microbial Keratitis among Wearers of a 30-Day Silicone Hydrogel Extended-Wear Contact Lens. Ophthalmology, 112(12), 2172-2179. doi:10.1016/j.ophtha.2005.09.014Sweeney, D. F. (2003). Clinical Signs of Hypoxia with High-Dk Soft Lens Extended Wear: Is the Cornea Convinced? Eye & Contact Lens: Science & Clinical Practice, S22-S25. doi:10.1097/00140068-200301001-00007HARVITT, D. M., & BONANNO, J. A. (1999). Re-Evaluation of the Oxygen Diffusion Model for Predicting Minimum Contact Lens Dk/t Values Needed to Avoid Corneal Anoxia. Optometry and Vision Science, 76(10), 712-719. doi:10.1097/00006324-199910000-00023Polse, K. A., & Mandell, R. B. (1970). Critical Oxygen Tension at the Corneal Surface. Archives of Ophthalmology, 84(4), 505-508. doi:10.1001/archopht.1970.00990040507021Giasson, C., & Bonanno, J. A. (1995). Acidification of rabbit corneal endothelium during contact lens wearin vitro. Current Eye Research, 14(4), 311-318. doi:10.3109/02713689509033531Riley, M. V. (1969). Glucose and oxygen utilization by the rabbit cornea. Experimental Eye Research, 8(2), 193-200. doi:10.1016/s0014-4835(69)80031-xFrahm, B., Lane, P., M�rkl, H., & P�rtner, R. (2003). Improvement of a mammalian cell culture process by adaptive, model-based dialysis fed-batch cultivation and suppression of apoptosis. Bioprocess and Biosystems Engineering, 26(1), 1-10. doi:10.1007/s00449-003-0335-zCompañ, V., Aguilella-Arzo, M., Del Castillo, L. F., Hernández, S. I., & Gonzalez-Meijome, J. M. (2016). Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2269-2281. doi:10.1002/jbm.b.33764Bonanno, J. A., Clark, C., Pruitt, J., & Alvord, L. (2009). Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans. Optometry and Vision Science, 86(8), E936-E942. doi:10.1097/opx.0b013e3181b2f582Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Diffusion and Monod kinetics to determine in vivo human corneal oxygen-consumption rate during soft contact-lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 90B(1), 202-209. doi:10.1002/jbm.b.31274Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2009). Modeling Corneal Metabolism and Oxygen Transport During Contact Lens Wear. Optometry and Vision Science, 86(5), 454-466. doi:10.1097/opx.0b013e31819f9e70Larrea, X., & Bu¨chler, P. (2009). A Transient Diffusion Model of the Cornea for the Assessment of Oxygen Diffusivity and Consumption. Investigative Opthalmology & Visual Science, 50(3), 1076. doi:10.1167/iovs.08-2479Alvord, L. A., Hall, W. J., Keyes, L. D., Morgan, C. F., & Winterton, L. C. (2007). Corneal Oxygen Distribution With Contact Lens Wear. Cornea, 26(6), 654-664. doi:10.1097/ico.0b013e31804f5a22Del Castillo, L. F., da Silva, A. R. F., Hernández, S. I., Aguilella, M., Andrio, A., Mollá, S., & Compañ, V. (2015). Diffusion and Monod kinetics model to determine in vivo human corneal oxygen-consumption rate during soft contact lens wear. Journal of Optometry, 8(1), 12-18. doi:10.1016/j.optom.2014.06.002Chandel, N. S., Budinger, G. R. S., Choe, S. H., & Schumacker, P. T. (1997). Cellular Respiration during Hypoxia. Journal of Biological Chemistry, 272(30), 18808-18816. doi:10.1074/jbc.272.30.18808Leung, B. K., Bonanno, J. A., & Radke, C. J. (2011). Oxygen-deficient metabolism and corneal edema. Progress in Retinal and Eye Research, 30(6), 471-492. doi:10.1016/j.preteyeres.2011.07.001Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Polarographic Method for Measuring Oxygen Diffusivity and Solubility in Water-Saturated Polymer Films:  Application to Hypertransmissible Soft Contact Lenses. Industrial & Engineering Chemistry Research, 47(10), 3540-3550. doi:10.1021/ie071071aCompañ, V., Andrio, A., López-Alemany, A., Riande, E., & Refojo, M. F. (2002). Oxygen permeability of hydrogel contact lenses with organosilicon moieties. Biomaterials, 23(13), 2767-2772. doi:10.1016/s0142-9612(02)00012-1Gonzalez-Meijome, J. M., Compañ-Moreno, V., & Riande, E. (2008). Determination of Oxygen Permeability in Soft Contact Lenses Using a Polarographic Method:  Estimation of Relevant Physiological Parameters. Industrial & Engineering Chemistry Research, 47(10), 3619-3629. doi:10.1021/ie071403bCompa�, V., L�pez, M. L., Andrio, A., L�pez-Alemany, A., & Refojo, M. F. (1999). Determination of the oxygen transmissibility and permeability of hydrogel contact lenses. Journal of Applied Polymer Science, 72(3), 321-327. doi:10.1002/(sici)1097-4628(19990418)72:33.0.co;2-lGavara, R., & Compañ, V. (2016). Oxygen, water, and sodium chloride transport in soft contact lenses materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2218-2231. doi:10.1002/jbm.b.33762Compañ, V., Tiemblo, P., García, F., García, J. M., Guzmán, J., & Riande, E. (2005). A potentiostatic study of oxygen transport through poly(2-ethoxyethyl methacrylate-co-2,3-dihydroxypropylmethacrylate) hydrogel membranes. Biomaterials, 26(18), 3783-3791. doi:10.1016/j.biomaterials.2004.09.061Wang, J., Fonn, D., Simpson, T. L., & Jones, L. (2003). Precorneal and Pre- and Postlens Tear Film Thickness Measured Indirectly with Optical Coherence Tomography. Investigative Opthalmology & Visual Science, 44(6), 2524. doi:10.1167/iovs.02-0731Nichols, J. J., & King-Smith, P. E. (2003). Thickness of the Pre- and Post–Contact Lens Tear Film Measured In Vivo by Interferometry. Investigative Opthalmology & Visual Science, 44(1), 68. doi:10.1167/iovs.02-0377Compañ, V., Aguilella-Arzo, M., Edrington, T. B., & Weissman, B. A. (2016). Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear. Optometry and Vision Science, 93(11), 1339-1348. doi:10.1097/opx.0000000000000988Compañ, V., Aguilella-Arzo, M., & Weissman, B. A. (2017). Corneal Equilibrium Flux as a Function of Corneal Surface Oxygen Tension. Optometry and Vision Science, 94(6), 672-679. doi:10.1097/opx.0000000000001083Papas, E. B., & Sweeney, D. F. (2016). Interpreting the corneal response to oxygen: Is there a basis for re-evaluating data from gas-goggle studies? Experimental Eye Research, 151, 222-226. doi:10.1016/j.exer.2016.08.019Alentiev, A. Y., Shantarovich, V. P., Merkel, T. C., Bondar, V. I., Freeman, B. D., & Yampolskii, Y. P. (2002). Gas and Vapor Sorption, Permeation, and Diffusion in Glassy Amorphous Teflon AF1600. Macromolecules, 35(25), 9513-9522. doi:10.1021/ma020494fLin, H., & Freeman, B. D. (2005). Gas and Vapor Solubility in Cross-Linked Poly(ethylene Glycol Diacrylate). Macromolecules, 38(20), 8394-8407. doi:10.1021/ma051218eKoros, W. J., Paul, D. R., & Rocha, A. A. (1976). Carbon dioxide sorption and transport in polycarbonate. Journal of Polymer Science: Polymer Physics Edition, 14(4), 687-702. doi:10.1002/pol.1976.180140410Nicolson, P. C., & Vogt, J. (2001). Soft contact lens polymers: an evolution. Biomaterials, 22(24), 3273-3283. doi:10.1016/s0142-9612(01)00165-xCheng, X., & Pinsky, P. M. (2017). A numerical model for metabolism, metabolite transport and edema in the human cornea. Computer Methods in Applied Mechanics and Engineering, 314, 323-344. doi:10.1016/j.cma.2016.09.014Li, L., & Tighe, B. (2005). Numerical simulation of corneal transport processes. Journal of The Royal Society Interface, 3(7), 303-310. doi:10.1098/rsif.2005.008

    Dimensionalities of Weak Solutions in Hydrogenic Systems

    Full text link
    A close inspection on the 3D hydrogen atom Hamiltonian revealed formal eigenvectors often discarded in the literature. Although not in its domain, such eigenvectors belong to the Hilbert space, and so their time evolution is well defined. They are then related to the 1D and 2D hydrogen atoms and it is numerically found that they have continuous components, so that ionization can take place

    Legendre transform in the thermodynamics of flowing polymer solutions

    Get PDF
    We propose a Legendre transform linking two different choices of nonequilibrium variables (viscous pressure tensor and configuration tensor) in the thermodynamics of flowing polymer solutions. This may avoid some current confusions in the analysis of thermodynamic effects in polymer solutions under flow

    Shear-induced shift of spinodal line in entangled polymer blends

    Get PDF
    We study the shear-flow effects on phase separation of entangled polymer blends by incorporating into the chemical potential a nonequilibrium contribution due to the flow. The results are compared with those of a previous analysis by other authors which did not modify the chemical potential but used a different assumption for the stress tensor of the blend

    A common mechanism of defective channel trafficking underlying DFNA2 hearing loss result in different cell surface expression levels of KCNQ4 mutants

    Get PDF
    KCNQ4 mutations underlie DFNA2, a subtype of autosomal dominant hearing loss. We had previously identified the pore-region p.G296S mutation that impaired channel activity in two manners: it greatly reduced surface expression and abolished channel function. Moreover, G296S mutant exerted a strong dominant-negative effect on potassium currents by reducing the channel expression at the cell surface representing the first study to identify a trafficking-dependent dominant mechanism for the loss of KCNQ4 channel function in DFNA2. Here, we have investigated the pathogenic mechanism associated with all the described KCNQ4 mutations (F182L, W242X, E260K, D262V, L274H, W276S, L281S, G285C, G285S and G321S) that are located in different domains of the channel protein. F182L mutant showed a wild type-like cell-surface distribution in transiently transfected NIH3T3 fibroblasts and the recorded currents in Xenopus oocytes resembled those of the wild-type. The remaining KCNQ4 mutants abolished potassium currents, but displayed distinct levels of defective cell-surface expression in NIH3T3 as quantified by flow citometry. Co-localization studies revealed these mutants were retained in the ER, unless W242X, which showed a clear co-localization with Golgi apparatus. Interestingly, this mutation results in a truncated KCNQ4 protein at the S5 transmembrane domain, before the pore region, that escapes the protein quality control in the ER but does not reach the cell surface at normal levels. Currently we are investigating the trafficking behaviour and electrophysiological properties of several KCNQ4 truncated proteins artificially generated in order to identify specific motifs involved in channel retention/exportation. Altogether, our results indicate that a defect in KCNQ4 trafficking is the common mechanism underlying DFNA

    Geometrothermodynamics

    Get PDF
    We present the fundamentals of geometrothermodynamics, an approach to study the properties of thermodynamic systems in terms of differential geometric concepts. It is based, on the one hand, upon the well-known contact structure of the thermodynamic phase space and, on the other hand, on the metric structure of the space of thermodynamic equilibrium states. In order to make these two structures compatible we introduce a Legendre invariant set of metrics in the phase space, and demand that their pullback generates metrics on the space of equilibrium states. We show that Weinhold's metric, which was introduced {\it ad hoc}, is not contained within this invariant set. We propose alternative metrics which allow us to redefine the concept of thermodynamic length in an invariant manner and to study phase transitions in terms of curvature singularities.Comment: Revised version, to be published in Jour. Math. Phy

    Long-time discrete particle effects versus kinetic theory in the self-consistent single-wave model

    Get PDF
    The influence of the finite number N of particles coupled to a monochromatic wave in a collisionless plasma is investigated. For growth as well as damping of the wave, discrete particle numerical simulations show an N-dependent long time behavior resulting from the dynamics of individual particles. This behavior differs from the one due to the numerical errors incurred by Vlasov approaches. Trapping oscillations are crucial to long time dynamics, as the wave oscillations are controlled by the particle distribution inhomogeneities and the pulsating separatrix crossings drive the relaxation towards thermal equilibrium.Comment: 11 pages incl. 13 figs. Phys. Rev. E, in pres

    Nyquist method for Wigner-Poisson quantum plasmas

    Get PDF
    By means of the Nyquist method, we investigate the linear stability of electrostatic waves in homogeneous equilibria of quantum plasmas described by the Wigner-Poisson system. We show that, unlike the classical Vlasov-Poisson system, the Wigner-Poisson case does not necessarily possess a Penrose functional determining its linear stability properties. The Nyquist method is then applied to a two-stream distribution, for which we obtain an exact, necessary and sufficient condition for linear stability, as well as to a bump-in-tail equilibrium.Comment: 6 figure
    corecore