334 research outputs found

    Control task substitution in semi-automated driving: does it matter what aspects are automated?

    Get PDF
    Objective: The study was designed to show how driver attention to the road scene and engagement of a choice of secondary tasks are affected by the level of automation provided to assist or take over the basic task of vehicle control. It was also designed to investigate the difference between support in longitudinal control and support in lateral control. Background: There is comparatively little literature on the implications of automation for drivers’ engagement in the driving task and for their willingness to engage in non-driving-related activities. Method: A study was carried out on a high-level driving simulator in which drivers experienced three levels of automation: manual driving, semiautomated driving with either longitudinal or lateral control provided, and highly automated driving with both longitudinal and lateral control provided. Drivers were free to pay attention to the roadway and traffic or to engage in a range of entertainment and grooming tasks. Results: Engagement in the nondriving tasks increased from manual to semiautomated driving and increased further with highly automated driving. There were substantial differences in attention to the road and traffic between the two types of semiautomated driving. Conclusion: The literature on automation and the various task analyses of driving do not currently help to explain the effects that were found. Lateral support and longitudinal support may be the same in terms of levels of automation but appear to be regarded rather differently by drivers

    Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements

    Get PDF
    PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- 0.10 with the clear Optima 38 CL. Straylight values were 0.97 +/- 0.10 and 1.0 +/- 0.10 log units with the amber and grey-green tinted CL, respectively. Differences in straylight between baseline (without CL) and with the clear CL in place were neither statistically significant (p = 0.066) nor was there a significant difference between baseline and the amber CL (p = 0.052). However, the grey-green CL showed a statistically significant difference from baseline (p = 0.006). Differences in straylight with the clear CL compared with the grey-green CL were also statistically different from zero (p = 0.002) showing an increased straylight value for the tinted CL. These differences were variable, but consistent for each subject, thus those showing higher or lower changes with one tinted lens tended to show the same trend with the second lens (r(2) = 0.736). CONCLUSIONS: Despite increases having been found in straylight values with tinted contact lenses, those changes are not likely to induce clinically significant changes in visual function under photopic conditions, even for the grey-green CL, which seems to increase straylight values more significantly than the amber CL. This difference between the tinted CL could suggest a wavelength dependence of straylight values, although this should be investigated further by controlling for pupil size and subjects' pigmentation, as well as by using neutral density filters

    Controlled Crystallization of the Lipophilic Drug Fenofibrate During Freeze-Drying: Elucidation of the Mechanism by In-Line Raman Spectroscopy

    Get PDF
    We developed a novel process, “controlled crystallization during freeze-drying” to produce drug nanocrystals of poorly water-soluble drugs. This process involves freeze-drying at a relatively high temperature of a drug and a matrix material from a mixture of tertiary butyl alcohol and water, resulting in drug nanocrystals incorporated in a matrix. The aim of this study was to elucidate the mechanisms that determine the size of the drug crystals. Fenofibrate was used as a model lipophilic drug. To monitor the crystallization during freeze-drying, a Raman probe was placed just above the sample in the freeze-dryer. These in-line Raman spectroscopy measurements clearly revealed when the different components crystallized during freeze-drying. The solvents crystallized only during the freezing step, while the solutes only crystallized after the temperature was increased, but before drying started. Although the solutes crystallized only after the freezing step, both the freezing rate and the shelf temperature were critical parameters that determined the final crystal size. At a higher freezing rate, smaller interstitial spaces containing the freeze-concentrated fraction were formed, resulting in smaller drug crystals (based on dissolution data). On the other hand, when the solutes crystallized at a lower shelf temperature, the degree of supersaturation is higher, resulting in a higher nucleation rate and consequently more and therefore smaller crystals. In conclusion, for the model drug fenofibrate, a high freezing rate and a relatively low crystallization temperature resulted in the smallest crystals and therefore the highest dissolution rate

    Aperture synthesis for gravitational-wave data analysis: Deterministic Sources

    Get PDF
    Gravitational wave detectors now under construction are sensitive to the phase of the incident gravitational waves. Correspondingly, the signals from the different detectors can be combined, in the analysis, to simulate a single detector of greater amplitude and directional sensitivity: in short, aperture synthesis. Here we consider the problem of aperture synthesis in the special case of a search for a source whose waveform is known in detail: \textit{e.g.,} compact binary inspiral. We derive the likelihood function for joint output of several detectors as a function of the parameters that describe the signal and find the optimal matched filter for the detection of the known signal. Our results allow for the presence of noise that is correlated between the several detectors. While their derivation is specialized to the case of Gaussian noise we show that the results obtained are, in fact, appropriate in a well-defined, information-theoretic sense even when the noise is non-Gaussian in character. The analysis described here stands in distinction to ``coincidence analyses'', wherein the data from each of several detectors is studied in isolation to produce a list of candidate events, which are then compared to search for coincidences that might indicate common origin in a gravitational wave signal. We compare these two analyses --- optimal filtering and coincidence --- in a series of numerical examples, showing that the optimal filtering analysis always yields a greater detection efficiency for given false alarm rate, even when the detector noise is strongly non-Gaussian.Comment: 39 pages, 4 figures, submitted to Phys. Rev.

    The MMSE should not be the sole indicator of fitness to drive in mild Alzheimer's dementia

    Get PDF
    Since Alzheimer’s disease may affect driving performance, patients with Alzheimer’s disease are assessed on fitness to drive. On-road driving assessments are widely used, and attempts have also been made to develop strategies to assess fitness to drive in a clinical setting. Preferably, a first indication of fitness to drive is obtained quickly after diagnosis using a single test such as the Mini-Mental State Examination (MMSE). The aim of this study is to investigate whether the MMSE can be used to predict whether patients with Alzheimer’s disease will pass or fail an on-road driving assessment. Patients with Alzheimer’s disease (n = 81) participated in a comprehensive fitness-to-drive assessment which included the MMSE as well as an on-road driving assessment [PLoS One 11(2):e0149566, 2016]. MMSE cutoffs were applied as suggested by Versijpt and colleagues [Acta Neurol Belg 117(4):811–819, 2017]. All patients with Alzheimer’s disease who scored below the lower cutoff (MMSE ≤ 19) failed the on-road driving assessment. However, a third of the patients with Alzheimer’s disease who scored above the upper cutoff (MMSE ≥ 25) failed the on-road driving assessment as well. We conclude that the MMSE alone has insufficient predictive value to correctly identify fitness to drive in patients with very mild-to-mild Alzheimer’s disease implicating the need for comprehensive assessments to determine fitness to drive in a clinical setting

    Priming of microglia in a DNA-repair deficient model of accelerated aging

    Get PDF
    AbstractAging is associated with reduced function, degenerative changes, and increased neuroinflammation of the central nervous system (CNS). Increasing evidence suggests that changes in microglia cells contribute to the age-related deterioration of the CNS. The most prominent age-related change of microglia is enhanced sensitivity to inflammatory stimuli, referred to as priming. It is unclear if priming is due to intrinsic microglia ageing or induced by the ageing neural environment. We have studied this in Ercc1 mutant mice, a DNA repair-deficient mouse model that displays features of accelerated aging in multiple tissues including the CNS. In Ercc1 mutant mice, microglia showed hallmark features of priming such as an exaggerated response to peripheral lipopolysaccharide exposure in terms of cytokine expression and phagocytosis. Specific targeting of the Ercc1 deletion to forebrain neurons resulted in a progressive priming response in microglia exemplified by phenotypic alterations. Summarizing, these data show that neuronal genotoxic stress is sufficient to switch microglia from a resting to a primed state

    A New Limit on the Neutrinoless DBD of 130Te

    Full text link
    We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK in the Gran Sasso Underground Laboratory. Temperature pulses induced by particle interacting in the crystals are recorded and measured by means of Neutron Transmutation Doped thermistors. The gain of each bolometer is stabilized with voltage pulses developed by a high stability pulse generator across heater resistors put in thermal contact with the absorber. The calibration is performed by means of two thoriated wires routinely inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of 130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the lifetime of this process. Taking largely into account the uncertainties in the theoretical values of nuclear matrix elements, this implies an upper boud on the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This sensitivity is similar to those of the 76Ge experiments.Comment: 4 pages, 2 figure

    Oocyte expression with injection of purified T7 RNA polymerase.

    Get PDF
    International audienceThe Xenopus oocyte is a widely used system for protein expression. Investigators have had the choice between two different techniques: injection into the cytoplasm of in vitro transcribed complementary RNA (cRNA) or injection into the nucleus of complementary DNA (cDNA). We report on a third expression technique that is based on the combined injection of cDNA and purified T7 RNA polymerase directly into the cytoplasm of oocytes

    The Search for Gravitational Waves

    Full text link
    Experiments aimed at searching for gravitational waves from astrophysical sources have been under development for the last 40 years, but only now are sensitivities reaching the level where there is a real possibility of detections being made within the next five years. In this article a history of detector development will be followed by a description of current detectors such as LIGO, VIRGO, GEO 600, TAMA 300, Nautilus and Auriga. Preliminary results from these detectors will be discussed and related to predicted detection rates for some types of sources. Experimental challenges for detector design are introduced and discussed in the context of detector developments for the future.Comment: 21 pages, 7 figures, accepted J. Phys. B: At. Mol. Opt. Phy

    Effect of surgical volume on short-term outcomes of cytoreductive surgery for advanced-stage ovarian cancer:A population-based study from the Dutch Gynecological Oncology Audit

    Get PDF
    Objective: Despite lacking clinical data, the Dutch government is considering increasing the minimum annual surgical volume per center from twenty to fifty cytoreductive surgeries (CRS) for advanced-stage ovarian cancer (OC). This study aims to evaluate whether this increase is warranted. Methods: This population-based study included all CRS for FIGO-stage IIB-IVB OC registered in eighteen Dutch hospitals between 2019 and 2022. Short-term outcomes included result of CRS, length of stay, severe complications, 30-day mortality, time to adjuvant chemotherapy, and textbook outcome. Patients were stratified by annual volume: low-volume (nine hospitals, &lt;25), medium-volume (four hospitals, 29–37), and high-volume (five hospitals, 54–84). Descriptive statistics and multilevel logistic regressions were used to assess the (case-mix adjusted) associations of surgical volume and outcomes. Results: A total of 1646 interval CRS (iCRS) and 789 primary CRS (pCRS) were included. No associations were found between surgical volume and different outcomes in the iCRS cohort. In the pCRS cohort, high-volume was associated with increased complete CRS rates (aOR 1.9, 95%-CI 1.2–3.1, p = 0.010). Furthermore, high-volume was associated with increased severe complication rates (aOR 2.3, 1.1–4.6, 95%-CI 1.3–4.2, p = 0.022) and prolonged length of stay (aOR 2.3, 95%-CI 1.3–4.2, p = 0.005). 30-day mortality, time to adjuvant chemotherapy, and textbook outcome were not associated with surgical volume in the pCRS cohort. Subgroup analyses (FIGO-stage IIIC-IVB) showed similar results. Various case-mix factors significantly impacted outcomes, warranting case-mix adjustment. Conclusions: Our analyses do not support further centralization of iCRS for advanced-stage OC. High-volume was associated with higher complete pCRS, suggesting either a more accurate selection in these hospitals or a more aggressive approach. The higher completeness rates were at the expense of higher severe complications and prolonged admissions.</p
    corecore