49 research outputs found

    Electrical behaviour, characteristics and properties of anodic aluminium oxide films coloured by nickel electrodeposition

    Get PDF
    Porous anodic films on 1050 aluminium substrate were coloured by AC electrodeposition of nickel. Several experiments were performed at different deposition voltages and nickel concentrations in the electrolyte in order to correlate the applied electrical power to the electrical behaviour, as well as the characteristics and properties of the coatings. The content of nickel inside the coatings reached 1.67 g/m2, depending on the experimental conditions. According to the applied AC voltage in comparison with the threshold voltage Ut, the coating either acted only as a capacitor when U\Ut and, when U[Ut, the behaviour during the anodic and cathodic parts of the power sine wave was different. In particular, due to the semi-conducting characteristics of the barrier layer, additional oxidation of the aluminium substrate occurred during the anodic part of the electrical signal, whilst metal deposition (and solvent reduction) occurred during the cathodic part; these mechanisms correspond to the blocked and pass directions of the barrier layer/electrolyte junction, respectively

    Demographic, clinical and antibody characteristics of patients with digital ulcers in systemic sclerosis: data from the DUO Registry

    Get PDF
    OBJECTIVES: The Digital Ulcers Outcome (DUO) Registry was designed to describe the clinical and antibody characteristics, disease course and outcomes of patients with digital ulcers associated with systemic sclerosis (SSc). METHODS: The DUO Registry is a European, prospective, multicentre, observational, registry of SSc patients with ongoing digital ulcer disease, irrespective of treatment regimen. Data collected included demographics, SSc duration, SSc subset, internal organ manifestations, autoantibodies, previous and ongoing interventions and complications related to digital ulcers. RESULTS: Up to 19 November 2010 a total of 2439 patients had enrolled into the registry. Most were classified as either limited cutaneous SSc (lcSSc; 52.2%) or diffuse cutaneous SSc (dcSSc; 36.9%). Digital ulcers developed earlier in patients with dcSSc compared with lcSSc. Almost all patients (95.7%) tested positive for antinuclear antibodies, 45.2% for anti-scleroderma-70 and 43.6% for anticentromere antibodies (ACA). The first digital ulcer in the anti-scleroderma-70-positive patient cohort occurred approximately 5 years earlier than the ACA-positive patient group. CONCLUSIONS: This study provides data from a large cohort of SSc patients with a history of digital ulcers. The early occurrence and high frequency of digital ulcer complications are especially seen in patients with dcSSc and/or anti-scleroderma-70 antibodies

    Inorganic Mass Spectrometry

    Get PDF
    To establish a method for sensitive, accurate, and precise determination of Se in real samples, isotope dilution analysis using high-power nitrogen microwave-induced plasma mass spectrometry (N 2 MIP-IDMS) was conducted. In this study, freeze-dried human blood serum (Standard Reference Material, NIES No. 4) provided by NIES (National Institute for Environmental Studies) was used as a real sample. The measured isotopes of Se were 78 Se and 80 Se which are the major isotopes of Se. The appropriate amount of a Se spike solution was theoretically calculated by using an error multiplication factor (F) and was confirmed experimentally for the isotope dilution analysis. The mass discrimination effect was corrected for by using a standard Se solution for the measurement of Se isotope ratios in the spiked sample. However, the sensitivity for the detection of Se was not so good and the precision of the determination was not improved (2-3%) by N 2 MIP-IDMS with use of the conventional nebulizer. Therefore, a hydride generation system was connected to N 2 MIP-IDMS as a sample introduction system (HG-N 2 MIP-IDMS) in order to establish a more sensitive detection and a more precise determination of Se. A detection limit (3σ) of 10 pg mL -1 could be achieved, and the RSD was less than 1% at the concentration level of 5.0-10.0 ng mL -1 by HG-N 2 MIP-IDMS. The analytical results were found to be in a good agreement with those obtained by the standard addition method using conventional Ar ICPMS. It is well-known that Se is an essential element for all mammals. Se deficiency leads to deficiency syndromes, for example, Keshan disease, which is known for cardiac insufficiency that occurred in children and pregnant women in China. Problems also occur if the concentration of Se is too high; for example, gastroenteric disorders, dermatitis, and neurotic disorders are caused by excessive intake of Se. Moreover, it is well-known that the range of permissive intake amounts of Se is very narrow for human beings. Therefore, it is restricted as a toxic element in environmental standards. There are several sources of environmental Se pollution: the processes of Se refinement and the production processes of Se-containing products. For these reasons, the accurate and precise determination of trace levels of Se in environmental and biological samples is required, and studies of Se determination have been reported by several groups. [1][2][3][4][5][6][7][8][9][10][11] Because Ar ICPMS can measure multiple elements at a concentration range from ng mL -1 to fg mL -1 , it has widespread use in the determination of trace elements in various samples. 12-25 However
    corecore