41 research outputs found

    Beam Test Results of the LHCb Electromagnetic Calorimeter.

    Get PDF
    The main properties of the LHCb electromagnetic calorimeter and a prototype of the monitoring system was studied at the X7 CERN test-beam facility. A dedicated MC simulation for light propagation in the scintillator tiles was developed and tuned with experimental data

    Design, construction, quality control and performance study with cosmic rays of modules for the LHCb electromagnetic calorimeter

    Get PDF
    Abstract This article addresses the design and construction of modules for the LHCb electromagnetic calorimeter. Quality control and preinstallation tests, including cells pre-calibration, are described and the results of light yield measurements are given

    The electromagnetic calorimeter of the HERA-B experiment

    Full text link
    The electromagnetic calorimeter of the HERA-B experiment built at the HERA proton accelerator at DESY (Hamburg) is described. The construction characteristics of the detector, of the related front-end, readout, trigger and service electronics are discussed together with the constraints and the motivations which inspired the design philosophy. The detector performance are presented as obtained from the analysis of the data acquired during the HERA-B running period, including calibration procedures and achievements and the electron identification capability exploiting a method, proposed here for the first time, based on the observation of the associated bremsstrahlung γ. Finally, some observed physical signals and a short overview of the main obtained physics results are presented

    Prompt K_short production in pp collisions at sqrt(s)=0.9 TeV

    Get PDF
    The production of K_short mesons in pp collisions at a centre-of-mass energy of 0.9 TeV is studied with the LHCb detector at the Large Hadron Collider. The luminosity of the analysed sample is determined using a novel technique, involving measurements of the beam currents, sizes and positions, and is found to be 6.8 +/- 1.0 microbarn^-1. The differential prompt K_short production cross-section is measured as a function of the K_short transverse momentum and rapidity in the region 0 < pT < 1.6 GeV/c and 2.5 < y < 4.0. The data are found to be in reasonable agreement with previous measurements and generator expectations.Comment: 6+18 pages, 6 figures, updated author lis

    ATLAS detector and physics performance: Technical Design Report, 1

    Get PDF

    LHCb calorimeters high voltage system

    No full text
    International audienceThe calorimeter system in LHCb aims to identify electrons, photons and hadrons. All calorimeters are equipped with Hamamatsu photo tubes as devices for light to signal conversion. Eight thousand R7899-20 tubes are used for electromagnetic and hadronic calorimeters and two hundred 64 channels multi-anode R7600-00-M64 for Scintillator-Pad/Preshower detectors. The calorimeter high voltage (HV) system is based on a Cockroft Walton (CW) voltage converter and a control board connected to the Experiment Control System (ECS) by serial bus. The base of each photomultiplier tube (PMT) is built with a high voltage converter and constructed on an individual printed circuit board, using compact surface mount components. The base is attached directly to the PMT. There are no HV cables in the system. A Field Programmable Gate Array (FPGA) is used on the control board as an interface between the ECS and the 200 control channels. The FPGA includes also additional functionalities allowing automated monitoring and ramp up of the high voltage values. This paper describes the HV system architecture, some technical details of the electronics implementation and summarizes the system performance. This safe and low power consumption HV electronic system for the photomultiplier tubes can be used for various biomedical apparatus to
    corecore