7 research outputs found

    Diagnostic accuracy of autoverification and guidance system for COVID-19 RT-PCR results

    Get PDF
    Background: To date, most countries worldwide have declared that the pandemic of COVID-19 is over, while the WHO has not officially ended the COVID-19 pandemic, and China still insists on the personalized dynamic COVID-free policy. Large-scale nucleic acid testing in Chinese communities and the manual interpretation for SARS-CoV-2 nucleic acid detection results pose a huge challenge for labour, quality and turnaround time (TAT) requirements. To solve this specific issue while increase the efficiency and accuracy of interpretation, we created an autoverification and guidance system (AGS) that can automatically interpret and report the COVID-19 reverse transcriptase-polymerase chain reaction (RT-PCR) results relaying on computer-based autoverification procedure and then validated its performance in real-world environments. This would be conductive to transmission risk prediction, COVID-19 prevention and control and timely medical treatment for positive patients in the context of the predictive, preventive and personalized medicine (PPPM). Methods: A diagnostic accuracy test was conducted with 380,693 participants from two COVID-19 test sites in China, the Hong Kong Hybribio Medical Laboratory (n = 266,035) and the mobile medical shelter at a Shanghai airport (n = 114,658). These participants underwent SARS-CoV-2 RT-PCR from March 28 to April 10, 2022. All RT-PCR results were interpreted by laboratorians and by using AGS simultaneously. Considering the manual interpretation as gold standard, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were applied to evaluate the diagnostic value of the AGS on the interpretation of RT-PCR results. Results: Among the 266,035 samples in Hong Kong, there were 16,356 (6.15%) positive, 231,073 (86.86%) negative, 18,606 (6.99%) indefinite, 231,073 (86.86%, negative) no retest required and 34,962 (13.14%, positive and indefinite) retest required; the 114,658 samples in Shanghai consisted of 76 (0.07%) positive, 109,956 (95.90%) negative, 4626 (4.03%) indefinite, 109,956 (95.90%, negative) no retest required and 4702 (4.10%, positive and indefinite) retest required. Compared to the fashioned manual interpretation, the AGS is a procedure of high accuracy [99.96% (95%CI, 99.95–99.97%) in Hong Kong and 100% (95%CI, 100–100%) in Shanghai] with perfect sensitivity [99.98% (95%CI, 99.97–99.98%) in Hong Kong and 100% (95%CI, 100–100%) in Shanghai], specificity [99.87% (95%CI, 99.82–99.90%) in Hong Kong and 100% (95%CI, 99.92–100%) in Shanghai], PPV [99.98% (95%CI, 99.97–99.99%) in Hong Kong and 100% (95%CI, 99.99–100%) in Shanghai] and NPV [99.85% (95%CI, 99.80–99.88%) in Hong Kong and 100% (95%CI, 99.90–100%) in Shanghai]. The need for manual interpretation of total samples was dramatically reduced from 100% to 13.1% and the interpretation time fell from 53 h to 26 min in Hong Kong; while the manual interpretation of total samples was decreased from 100% to 4.1% and the interpretation time dropped from 20 h to 16 min at Shanghai. Conclusions: The AGS is a procedure of high accuracy and significantly relieves both labour and time from the challenge of large-scale screening of SARS-CoV-2 using RT-PCR. It should be recommended as a powerful screening, diagnostic and predictive system for SARS-CoV-2 to contribute timely the ending of the COVID-19 pandemic following the concept of PPPM

    Systematic Engineering of Single Substitution in Zirconium Metal–Organic Frameworks toward High-Performance Catalysis

    No full text
    Zirconium-based metal–organic frameworks (Zr-MOFs) exhibit great structural tunability and outstanding chemical stability, rendering them promising candidates for a wide range of practical applications. In this work, we synthesized a series of isostructural PCN-224 analogues functionalized by ethyl, bromo, chloro, and fluoro groups on the porphyrin unit, which allowed us to explicitly study the effects of electron-donating and electron-withdrawing substituents on catalytic performance in MOFs. Owing to the different electronic properties of ethyl, bromo, chloro, and fluoro substitutes, the molecular-level control over the chemical environment surrounding a catalytic center could be readily achieved in our MOFs. To investigate the effects of these substitutes on catalytic activity and selectivity, the oxidation of 3-methylpentane to corresponding alcohols and ketones was utilized as a model reaction. Within these five analogues of PCN-224, an extremely high turnover number of 7680 and turnover frequency of 10 240 h<sup>–1</sup> was achieved by simply altering the substitutes on porphyrin rings. Moreover, a remarkable 99% selectivity of the tertiary alcohol over the five other possible by-products are realized. We demonstrate that this strategy can be used to efficiently screen a suitable peripheral environment around catalytic cores in MOFs for catalysis
    corecore