3,588 research outputs found

    Ion trap long-range XY model for quantum state transfer and optimal spatial search

    Get PDF
    Linear ion trap chains are a promising platform for quantum computation and simulation. The XY model with long-range interactions can be implemented with a single side-band Mølmer–Sørensen scheme, giving interactions that decay as 1/r α, where α parameterises the interaction range. Lower α leads to longer range interactions, allowing faster long-range gate operations for quantum computing. However, decreasing α causes an increased generation of coherent phonons and appears to dephase the effective XY interaction model. We characterise and show how to correct for this effect completely, allowing lower α interactions to be coherently implemented. Ion trap chains are thus shown to be a viable platform for spatial quantum search in optimal O( √ N) time, for N ions. Finally, we introduce a O( √ N) quantum state transfer protocol, with a qubit encoding that maintains a high fidelity

    Evolution of precision agriculture computing towards sustainable oil palm industry

    Get PDF
    Precision technology elements have not been implemented yet into the sustainable oil palm industry because the knowledge and technology gap. To resolve the gaps, promote sustainability and integrate the technologies, Oil Palm Management System (OPAMS) was introduced. The precision technologies in OPAMS comprises of Geographical Information System (GIS), Global Positioning System (GPS), remote sensing and yield monitoring. A phase by phase System Development Life Cycle (SDLC) methodology was used to generate the said system with feedbacks from oil palm planters as the inputs for OPAMS’s key features. OPAMS ultimately aims to increase the awareness of the industry on the benefits of utilizing technology to improve plantation performances, increase business and environmental sustainability

    Greenlight laser™ photovaporization versus transurethral resection of the prostate: A systematic review and meta-analysis

    Get PDF
    none9GreenLight laser™ photovaporization of the prostate (GLL-PVP) has become a valid alternative to traditional transurethral resection of the prostate (TURP) in men requiring surgery for benign prostatic hyperplasia. We aimed to review systematically the safety and efficacy of studies comparing GLL PVP and TURP in the medium-term. A comprehensive literature search was performed. Twelve studies were identified for meta-analysis. Meta-analyses showed a longer postoperative catheterization time (risk ratio (RR): 1.12, 95% CI:1.09–1.14, p<0.00001) and length of stay (RR: 1.16, 95% CI:1.12–1.19, p<0.00001) in the TURP group; higher risk of transfusion in the TURP group (RR: 6.51, 95% CI: 2,90–14,64 p<0.00001); no difference in the risk of urinary tract infections (RR: 0.83, 95% CI: 0.58–1.18, p=0.30) and transient re-catheterization (RR: 1.11, 95% CI: 0.76–1.60, p=0.60). Regarding reoperation rate, no difference was found in term of postoperative urethral stricture (RR: 1.13, 95% CI: 0.73–1.75, p=0.59) and bladder neck contracture (RR: 0.66, 95% CI: 0.31–1.40, p=0.28). A significantly higher incidence in reoperation for persistent/regrowth adenoma was present in the GLLL-PVP (RR: 0.64, 95% CI: 0.41–0.99, p=0.05). Data at 2-year follow-up showed significant better post-voiding residual (PVR) (MD:-1.42, 95% CI:-2.01,-0.82, p<0.00001) and International Prostate Symptom Score (IPSS) (MD:-0.35, 95% CI:-0.50,-0.20, p<0.00001) after TURP. No difference was found in the mean PVR at 2 years after TURP, in the mean maximum flow rate (Qmax) (MD: 0.30, 95% CI:-0.02–0.61, p=0.06) and quality of life QoL score (MD: 0.05, 95% CI:-0.02–0.42, p=0.13). At 5-year follow-up, data showed better IPSS (MD:-1.70, 95% CI:-2.45,-0.95, p<0.00001), QoL scores (MD:-0.35, 95% CI:-0.69,-0.02, p=0.04) and Qmax (MD: 3.29, 95% CI: 0.19–6.38, p=0.04) after TURP. Data of PVR showed no significant difference (MD:-11.54, 95% CI:-29.55–6.46, p=0.21). In conclusion, our analysis shows that GLL-PVP is a safer and more efficacious procedure than standard TURP in the early and medium-term. However, in the long term period GLL-PVP showed a higher incidence of reoperation rate due to incomplete vaporization/regrowth of prostatic adenoma.openCastellani D.; Pirola G.M.; Rubilotta E.; Gubbiotti M.; Scarcella S.; Maggi M.; Gauhar V.; Teoh J.Y.-C.; Galosi A.B.Castellani, D.; Pirola, G. M.; Rubilotta, E.; Gubbiotti, M.; Scarcella, S.; Maggi, M.; Gauhar, V.; Teoh, J. Y. -C.; Galosi, A. B

    Tapered microchannel for multi-particles passive separation based on hydrodynamic resistance

    Get PDF
    Researches on separation of multi-particles utilizing microfluidic have been flourishing in recent years with the aid from advancements in microfabrication design and technology. Generally, separation is beneficial for biomedical application especially involving heterogeneous samples. Due to inherent problems of samples isolation, a simple and efficient separation device is required. Here, we present a passive tapered microchannel for multi-particles separation using hydrodynamic principle. Our emphasis is on the effect of hydrodynamic resistance coupled with tapered microchannel design. In the experiment, successful multi-particles samples separation was observed. The results were further analyzed and were in agreement with the proposed concept. This method opens the route toward robust, low-cost and high-throughput, thus it may holds potential to be integrated as one functional module in Micro Total Analysis System (µTAS)

    Predictors of allergen sensitization in Singapore children from birth to 3 years

    Get PDF
    10.1186/s13223-016-0161-xAllergy, asthma, and clinical immunology : official journal of the Canadian Society of Allergy and Clinical Immunology121Article number 56GUSTO (Growing up towards Healthy Outcomes

    Inhibitory role of peroxisome proliferator-activated receptor gamma in hepatocarcinogenesis in mice and in vitro

    Get PDF
    Although peroxisome proliferator-activated receptor gamma (PPARγ) agonist have been shown to inhibit hepatocellular carcinoma (HCC) development, the role of PPARγ in hepatocarcinogenesis remains unclear. We investigated the therapeutic efficacy of PPAR

    EXACT RUN LENGTH DISTRIBUTION OF THE DOUBLE SAMPLING X CHART WITH ESTIMATED PROCESS PARAMETERS

    Get PDF
    Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL) criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS) X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL). A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose

    EXACT RUN LENGTH DISTRIBUTION OF THE DOUBLE SAMPLING X CHART WITH ESTIMATED PROCESS PARAMETERS

    Get PDF
    Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL) criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS) X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL). A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose

    Outpatient-Based Therapy of Oral Fludarabine and Subcutaneous Alemtuzumab for Asian Patients with Relapsed/Refractory Chronic Lymphocytic Leukemia

    Get PDF
    Background. Intravenous alemtuzumab and fludarabine are effective in combination for the treatment of chronic lymphocytic leukemia (CLL), but require hospital visits for intravenous injection. We performed a pilot study to assess the safety and efficacy of outpatient-based oral fludarabine with subcutaneous alemtuzumab (OFSA) for the treatment of relapsed/refractory CLL. Results. Depending on their response, patients were given two to six 28-day cycles of subcutaneous alemtuzumab 30 mg on days 1,3, and 5 and oral fludarabine 40 mg/m2/day for 5 days. Median patient age was 74. The lymphocyte counts of all five patients fell after the 1st cycle of treatment and reached normal/low levels on completion of 2 to 6 cycles of therapy. Platelet counts and hemoglobin were unaffected. All five patients achieved complete hematological remission, while two attained minimal residual disease negativity on 4-color flow cytometry. Conclusions. Our OFSA regimen was effective in elderly Asian patients with relapsed/refractory CLL, and it should be investigated further
    corecore