1,093 research outputs found

    Large gap magnetic suspension system

    Get PDF
    The design of a large gap magnetic suspension system is discussed. Some of the topics covered include: the system configuration, permanent magnet material, levitation magnet system, superconducting magnets, resistive magnets, superconducting levitation coils, resistive levitation coils, levitation magnet system, and the nitrogen cooled magnet system

    Magnetic suspension and balance system advanced study, 1989 design

    Get PDF
    The objectives are to experimentally confirm several advanced design concepts on the Magnetic Suspension and Balance Systems (MSBS). The advanced design concepts were identified as potential improvements by Madison Magnetics, Inc. (MMI) during 1984 and 1985 studies of an MSBS utilizing 14 external superconductive coils and a superconductive solenoid in an airplane test model suspended in a wind tunnel. This study confirmed several advanced design concepts on magnetic suspension and balance systems. The 1989 MSBS redesign is based on the results of these experiments. Savings of up to 30 percent in supporting magnet ampere meters and 50 percent in energy stored over the 1985 design were achieved

    Hypoxia in the Lower Rappahannock Estuary

    Get PDF
    There are several objectives to this study. The immediate objective is to collect a comprehensive and consistent set of field observations to better describe the hypoxic condition in the Rappahannock River. Other objectives can be classified as short and long term goals. Long term: (1) Identify and quantify the processes contributing to the dissolved oxygen budget in deep waters, and explain the variabilities among the three Virginia major tributary estuaries. (2) Provide information for resource management so that the James River can be protected from hypoxic problems and, perhaps, the problems in the York and Rappahannock Rivers can be alleviated. Short term: (1) Is the hypoxic condition in the Rappahannock River just an extension of that in Chesapeake Bay, or does it originate locally within the river

    Physiological factors affecting the production of an antimicrobial substance by Streptomyces violatus in batch cultures

    Get PDF
    Egyptian Journal of Biology Vol.3 2001: 1-1

    Comprehensive thermal and structural characterization of antimony-phosphate glass

    Get PDF
    For the first time, we prepare new ternary glass systems of composition (95-x)Sb2O3-xP2O5-5MgO, where x = 45, 40, 35 mol%; (85-x)Sb2O3-xP2O5-15MgO, where x = 55, 35, 25 mol%; (75-x)Sb2O3-xP2O5-25MgO, where x = 45, 35, 25 mol%; and 60Sb2O3-(40-x)P2O5-xMgO, where x = 10, 20 mol% via melt-quenching method. Synthesized glasses are characterized using XRD, FESEM, EDX, and TG/DTA measurements. The influence of varying modifier concentrations on their thermal properties is evaluated. The XRD patterns confirmed the amorphous nature of samples. SEM images demonstrated interesting phase formation with ribbons-like texture. Five crystalline phases are evidenced in the ternary diagram which are antimony phosphate and antimony orthophosphate as major phases as well as magnesium phosphate, magnesium cyclo-tetraphosphate and cervantite as minor phases. EDX spectra detected the right elemental traces. Detailed thermal analysis of these glasses revealed their high-molecular polymer character for Sb2O3 content greater than 50 mol%. Three different glass transition temperatures are achieved around 276, 380–381 and 422–470 °C depending on the composition. Furthermore, the solidus and liquidus temperature are found to decrease with increasing Sb2O3 and increases for MgO contents till 15 mol% and then decrease, where the lowest recorded solidus temperature is 426 °C. This observation may open up new research avenues for antimony based ternary glasses and an exploitation of the derived results for optoelectronics applications, photonic devices and non-linear optical devices

    Implementing Mechatronics Design Methodology in Mechanical Engineering Technology Senior Design Projects at the Old Dominion University

    Get PDF
    In recent years, the nature of engineering design has changed due to advances in embedded system design and computer technologies. It is rare to engineer a purely mechanical design that does not incorporate electrical and electronic components. Mechanical engineers and mechanical engineering technologists must possess a multi-disciplinary knowledge with the understanding of both mechanical and electrical systems. For this purpose, undergraduate programs in engineering technology have added mechatronics courses to their curriculum. Mechatronics is a design process that is multi-disciplinary in nature and integrates principles of many engineering disciplines including, but not limited to, mechanical engineering, electrical engineering, and controls engineering. These courses typically incorporate problem-based learning and project-based pedagogy to effectively build the student’s knowledge and understanding. Old Dominion University’s Mechanical Engineering Technology (ODU MET) program offers undergraduate courses related to Advanced Manufacturing including Robotics; Automation; Lean Manufacturing; Computer Integrated Manufacturing; and Advanced Manufacturing Processes. Recently, two new courses related to mechatronics were added to the same focus area. In addition, ODU MET program has placed an increased emphasis on mechatronics for students’ senior design projects. This paper highlights the benefits of including mechatronics in the ODU MET curriculum and presents several recent senior design projects that showcase how the student has incorporated multi-disciplinary principles into the design and build of a functional mechatronic device. By embedding these experience into their senior design project, students are exposed to other engineering technology areas, learn the terminology of other professions, and feel more confident to join the workforce with the cross-disciplinary skills needed to be successful

    Role of Sulfur as a Reducing Agent for the Transition Metals Incorporated into Lithium Silicate Glass

    Get PDF
    Li2O·0.25Fe2O3·0.25NiO·1.5SiO2 glass was prepared with and without 5 wt % sulfur (S) while melting the mixture of the starting materials at 1350 °C for 1 h in air. A part of the as-prepared glass was heat treated for 1 h near its crystallization temperature (Tc) as determined from differential thermal analysis. Each glass was also investigated by means of Mössbauer spectroscopy, X-ray diffraction, FTIR, and DC conductivity. The Mössbauer spectra showed ionic Fe2+ and Fe3+ species in the glass as well as in the precipitated phase obtained after heat treatment. XRD patterns demonstrated the glassy phase formation in the as-quenched samples irrespective of the presence of sulfur. The heat treated samples showed different precipitated phases containing iron particles of nanometer size. The electric conductivity measurements showed that sulfur-doped samples had high values of (σ) probably because of small polaron hopping between Fe2+ and Fe3+

    Modeling Surface Recombination at the p-Type Si/SiO

    Get PDF
    An integral model is proposed for recombination at the silicon/silicon dioxide (Si/SiO2) interface of thermally oxidized p-type silicon via Pb amphoteric centers associated with surface dangling bonds. The proposed model is a surface adaptation of a model developed for bulk recombination in amorphous silicon based on Sah-Shockley statistics which is more appropriate for amphoteric center recombination than classical Shockley-Read-Hall statistics. It is found that the surface recombination via amphoteric centers having capture cross-sections larger for charged centers than for neutral centers is distinguished from Shockley-Read-Hall recombination by exhibiting two peaks rather than one peak when plotted versus surface potential. Expressions are derived for the surface potentials at which the peaks occur. Such a finding provides a firm and plausible interpretation for the double peak surface recombination current measured in gated diodes or gated transistors. Successful fitting is possible between the results of the model and reported experimental curves showing two peaks for surface recombination velocity versus surface potential. On the other hand, if charged and neutral center capture cross-sections are equal or close to equal, surface recombination via amphoteric centers follows the same trend as Shockley-Read-Hall recombination and both models lead to comparable surface recombination velocities

    Multilayer perceptron neural network-based QoS-aware, content-aware and device-aware QoE prediction model : a proposed prediction model for medical ultrasound streaming over small cell networks

    Get PDF
    This paper presents a QoS-aware, content-aware and device-aware non-intrusive medical QoE (m-QoE) prediction model over small cell networks. The proposed prediction model utilises a Multilayer Perceptron (MLP) neural network to predict m-QoE. It also acts as a platform to maintain and optimise the acceptable diagnostic quality through a device-aware adaptive video streaming mechanism. The proposed model is trained for an unseen dataset of input variables such as QoS, content features, and display device characteristics, to produce an output value in the form of m-QoE (i.e. MOS). The efficiency of the proposed model is validated through subjective tests carried by medical experts. The prediction accuracy obtained via the correlation coefficient and Root Mean-Square-Error (RMSE) indicates that the proposed model succeeds in measuring m-QoE closer to the visual perception of the medical experts. Furthermore, we have addressed the following two main research questions: (1) How significant is ultrasound video content type in determining m-QoE? and (2) How much of a role does the screen size and device resolution play in medical experts’ diagnostic experience? The former is answered through the content classification of ultrasound video sequences based on their spatio-temporal features, by including these features in the proposed prediction model, and validating their significance through medical experts’ subjective ratings. The latter is answered by conducting a novel subjective experiment of the ultrasound video sequences across multiple devices
    corecore