    Development of a 1 GS/s high-resolution transient recorder

    Get PDF
    With present-day detectors in high energy physics one is often faced with short analog pulses of a few nanoseconds length which may cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high accuracy. Additionally, the data rate per readout channel can reach several MHz, which makes high demands on the separation of pile-up pulses. For such applications we have built the GANDALF transient recorder with a resolution of 12bit@1GS/s and an analog bandwidth of 500 MHz. Signals are digitized and processed by fast algorithms to extract pulse arrival times and amplitudes in real-time and to generate experiment trigger signals. With up to 16 analog channels, deep memories and a high data rate interface, this 6U-VME64x/VXS module is not only a dead-time free digitization unit but also has huge numerical capabilities provided by the implementation of a Virtex5-SXT FPGA. Fast algorithms implemented in the FPGA may be used to disentangle possible pile-up pulses and determine timing information from sampled pulse shapes with a time resolution in the picosecond range. Recently the application spectrum has been extended by implementing a 128-channel time-to-digital converter inside the FPGA and an appropriate input mezzanine card

    Spatially resolved simulation of a radio frequency driven micro atmospheric pressure plasma jet and its effluent

    Full text link
    Radio frequency driven plasma jets are frequently employed as efficient plasma sources for surface modification and other processes at atmospheric pressure. The radio-frequency driven micro atmospheric pressure plasma jet (μ\muAPPJ) is a particular variant of that concept whose geometry allows direct optical access. In this work, the characteristics of the μ\muAPPJ operated with a helium-oxygen mixture and its interaction with a helium environment are studied by numerical simulation. The density and temperature of the electrons, as well as the concentration of all reactive species are studied both in the jet itself and in its effluent. It is found that the effluent is essentially free of charge carriers but contains a substantial amount of activated oxygen (O, O3_3 and O2(1Δ)_2(^1\Delta)). The simulation results are verified by comparison with experimental data

    Characterization of RNA content in individual phase-separated coacervate microdroplets

    Get PDF
    Condensates formed by complex coacervation are hypothesized to have played a crucial part during the origin-of-life. In living cells, condensation organizes biomolecules into a wide range of membraneless compartments. Although RNA is a key component of biological condensates and the central component of the RNA world hypothesis, little is known about what determines RNA accumulation in condensates and to which extend single condensates differ in their RNA composition. To address this, we developed an approach to read the RNA content from single synthetic and protein-based condensates using high-throughput sequencing. We find that certain RNAs efficiently accumulate in condensates. These RNAs are strongly enriched in sequence motifs which show high sequence similarity to short interspersed elements (SINEs). We observe similar results for protein-derived condensates, demonstrating applicability across different in vitro reconstituted membraneless organelles. Thus, our results provide a new inroad to explore the RNA content of phase-separated droplets at single condensate resolution

    Reducing unnecessary prescriptions of antibiotics for acute cough: Adaptation of a leaflet aimed at Turkish immigrants in Germany

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The reduction in the number of unnecessary prescriptions of antibiotics has become one of the most important objectives for primary health care. German GPs report that they are under "pressure to prescribe" antibiotics particularly in consultations with Turkish immigrants. And so a qualitative approach was used to learn more about the socio-medical context of Turkish patients in regard to acute coughs. A German leaflet designed to improve the doctor-patient communication has been positively tested and then adapted for Turkish patients.</p> <p>Methods</p> <p>The original leaflet was first translated into Turkish. Then 57 patients belonging to 8 different GPs were interviewed about the leaflet using a semi-standardised script. The material was audio recorded, fully transcribed, and analysed by three independent researchers. As a first step a comprehensive content analysis was performed. Secondly, elements crucial to any Turkish version of the leaflet were identified.</p> <p>Results</p> <p>The interviews showed that the leaflets' messages were clearly understood by all patients irrespective of age, gender, and educational background. We identified no major problems in the perception of the translated leaflet but identified several minor points which could be improved. We found that patients were starting to reconsider their attitudes after reading the leaflet.</p> <p>Conclusion</p> <p>The leaflet successfully imparted relevant and new information to the target patients. A qualitative approach is a feasible way to prove general acceptance and provides additional information for its adaptation to medico-cultural factors.</p

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised proton

    Get PDF
    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.Comment: 15 pages, 13 figures and 1 tabl

    Measurement of the charged-pion polarisability

    Get PDF
    The COMPASS collaboration at CERN has investigated pion Compton scattering, πγπγ\pi^-\gamma\rightarrow \pi^-\gamma, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction πNiπγ  Ni\pi^-\mathrm{Ni}\rightarrow\pi^-\gamma\;\mathrm{Ni}, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, Q2<0.0015Q^2<0.0015\,(GeV/cc)2^2. From a sample of 63\,000 events the pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3undertheassumption under the assumption \alpha_\pi=-\beta_\pi$, which relates the electric and magnetic dipole polarisabilities. It is the most precise measurement of this fundamental low-energy parameter of strong interaction, that has been addressed since long by various methods with conflicting outcomes. While this result is in tension with previous dedicated measurements, it is found in agreement with the expectation from chiral perturbation theory. An additional measurement replacing pions by muons, for which the cross-section behavior is unambigiously known, was performed for an independent estimate of the systematic uncertainty.Comment: Published version: 9 pages, 3 figures, 1 tabl