645 research outputs found

    Development of Slowed Down Beams at the Fragment Separator for FAIR

    Get PDF
    The feasibility studies of the slowed down beam setup involving deceleration of a 64Ni beam at 250 MeV/u to 13 MeV/u in a thick Al degrader was performed at the FRagment Separator (FRS) at GSI. The experimentally measured energy spread and the nuclear reaction yields in the degrader are in good agreement with simulations

    Increased adherence to perioperative safety guidelines associated with improved patient safety outcomes:a stepped-wedge, cluster-randomised multicentre trial

    Get PDF
    Background: National Dutch guidelines have been introduced to improve suboptimal perioperative care. A multifaceted implementation programme (IMPlementatie Richtlijnen Operatieve VEiligheid [IMPROVE]) has been developed to support hospitals in applying these guidelines. This study evaluated the effectiveness of IMPROVE on guideline adherence and the association between guideline adherence and patient safety. Methods: Nine hospitals participated in this unblinded, superiority, stepped-wedge, cluster RCT in patients with major noncardiac surgery (mortality risk >= 1%). IMPROVE consisted of educational activities, audit and feedback, reminders, organisational, team-directed, and patient-mediated activities. The primary outcome of the study was guideline adherence measured by nine patient safety indicators on the process (stop moments from the composite STOP bundle, and timely administration of antibiotics) and on the structure of perioperative care. Secondary safety outcomes included in-hospital complications, postoperative wound infections, mortality, length of hospital stay, and unplanned care. Results: Data were analysed for 1934 patients. The IMPROVE programme improved one stop moment: 'discharge from recovery room' (+16%; 95% confidence interval [CI], 9-23%). This stop moment was related to decreased mortality (-3%; 95% CI, -4% to -1%), fewer complications (-8%; 95% CI, -13% to -3%), and fewer unscheduled transfers to the ICU (-6%; 95% CI, -9% to -3%). IMPROVE negatively affected one other stop moment - 'discharge from the hospital' - possibly because of the limited resources of hospitals to improve all stop moments together. Conclusions: Mixed implementation effects of IMPROVE were found. We found some positive associations between guideline adherence and patient safety (i.e. mortality, complications, and unscheduled transfers to the ICU) except for the timely administration of antibiotics

    On the two first excited K=0 bands in U-238 and Pu-240

    Get PDF
    EO-enhanced spectra of conversion electrons taken after (alpha,alpha) and (alpha,2n) reactions and after projectile Coulomb excitation improve our knowledge about first and second excited bands in U-238 and Pu-240 built on O-2(+) and O-3(+) states which lie anomalously close together. The two bands are of different structure.</p

    Reducing work pressure and IT problems and facilitating IT integration and audit &amp; feedback help adherence to perioperative safety guidelines: a survey among 95 perioperative professionals

    Get PDF
    Background: To improve perioperative patient safety, guidelines for the preoperative, peroperative, andpostoperative phase were introduced in the Netherlands between 2010 and 2013. To help the implementation ofthese guidelines, we aimed to get a better understanding of the barriers and drivers of perioperative guidelineadherence and to explore what can be learned for future implementation projects in complex organizations.Methods: We developed a questionnaire survey based on the theoretical framework of Van Sluisveld et al. forclassifying barriers and facilitators. The questionnaire contained 57 statements derived from (a) an instrument formeasuring determinants of innovations by the Dutch Organization for Applied Scientific Research, (b) interviewswith quality and safety policy officers and perioperative professionals, and (c) a publication of Cabana et al. Thetarget group consisted of 232 perioperative professionals in nine hospitals. In addition to rating the statements on afive-point Likert scale (which were classified into the seven categories of the framework: factors relating to theintervention, society, implementation, organization, professional, patients, and social factors), respondents wereinvited to rank their three most important barriers in a separate, extra open-ended question.Results: Ninety-five professionals (41%) completed the questionnaire. Fifteen statements (26%) were considered tobe barriers, relating to social factors (N = 5), the organization (N = 4), the professional (N = 4), the patient (N = 1),and the intervention (N = 1). An integrated information system was considered an important facilitator (70.4%) aswell as audit and feedback (41.8%). The Barriers Top-3 question resulted in 75 different barriers in nearly allcategories. The most frequently reported barriers were as follows: time pressure (16% of the total number ofbarriers), emergency patients (8%), inefficient IT structure (4%), and workload (3%).Conclusions: We identified a wide range of barriers that are believed to hinder the use of the perioperative safetyguidelines, while an integrated information system and local data collection and feedback will also be necessary toengage perioperative teams. These barriers need to be locally prioritized and addressed by tailored implementationstrategies. These results may also be of relevance for guideline implementation in general in complex organizations.Trial registration: Dutch Trial Registry: NTR3568.Keywords: Guideline adherence, Implementation, Implementation barriers, Implementation facilitators, Patientsafety, Perioperative car

    Core-coupled states and split proton-neutron quasi-particle multiplets in 122-126Ag

    Get PDF
    Neutron-rich silver isotopes were populated in the fragmentation of a 136Xe beam and the relativistic fission of 238U. The fragments were mass analyzed with the GSI Fragment separator and subsequently implanted into a passive stopper. Isomeric transitions were detected by 105 HPGe detectors. Eight isomeric states were observed in 122-126Ag nuclei. The level schemes of 122,123,125Ag were revised and extended with isomeric transitions being observed for the first time. The excited states in the odd-mass silver isotopes are interpreted as core-coupled states. The isomeric states in the even-mass silver isotopes are discussed in the framework of the proton-neutron split multiplets. The results of shell-model calculations, performed for the most neutron-rich silver nuclei are compared to the experimental data

    Direct observation of long-lived isomers in 212^{212}Bi

    Get PDF
    Long-lived isomers in 212Bi have been studied following 238U projectile fragmentation at 670 MeV per nucleon. The fragmentation products were injected as highly charged ions into the GSI storage ring, giving access to masses and half-lives. While the excitation energy of the first isomer of 212Bi was confirmed, the second isomer was observed at 1478(30) keV, in contrast to the previously accepted value of >1910 keV. It was also found to have an extended Lorentz-corrected in-ring halflife >30 min, compared to 7.0(3) min for the neutral atom. Both the energy and half-life differences can be understood as being due a substantial, though previously unrecognised, internal decay branch for neutral atoms. Earlier shell-model calculations are now found to give good agreement with the isomer excitation energy. Furthermore, these and new calculations predict the existence of states at slightly higher energy that could facilitate isomer de-excitation studies.Comment: published in PRL 110, 12250

    Evidence for reduced collectivity around the neutron mid-shell in the stable even-mass Sn isotopes from new lifetime measurements

    Get PDF
    Precise measurements of the lifetimes of the first excited 2+ states in the stable even-A Sn isotopes 112-124Sn have been performed using the Doppler shift attenuation technique. For the isotopes 112Sn, 114Sn and 116Sn the E2 transition strengths deduced from the measured lifetimes are in disagreement with the previously reported values and indicate a shallow minimum at N=66. The observed deviation from a maximum at mid-shell is attributed to the obstructive effect of the s1/2 neutron orbital in generating collectivity when near the Fermi level. © 2010 Elsevier B.V.Financial support from the Spanish Ministerio de Ciencia e Innovaci on under contracts FPA2007-66069, FPA2009-13377-C02-01 and FPA2009-13377-C02-02, the Spanish Consolider-Ingenio 2010 Programme CPAN (CSD2007-00042) and the Australian Re- search Council Discovery Scheme, grant no. DP0773273Peer Reviewe
    corecore