14 research outputs found

    Lubrication synergy: Mixture of hyaluronan and dipalmitoylphosphatidylcholine (DPPC) vesicles

    Get PDF
    AbstractPhospholipids and hyaluronan have been implied to fulfil important roles in synovial joint lubrication. Since both components are present in synovial fluid, self-assembly structures formed by them should also be present. We demonstrate by small angle X-ray scattering that hyaluronan associates with the outer shell of dipalmitoylphophatidylcholine (DPPC) vesicles in bulk solution. Further, we follow adsorption to silica from mixed hyaluronan/DPPC vesicle solution by Quartz Crystal Microbalance with Dissipation measurements. Atomic Force Microscope imaging visualises the adsorbed layer structure consisting of non-homogeneous phospholipid bilayer with hyaluronan/DPPC aggregates on top. The presence of these aggregates generates a long-range repulsive surface force as two such surfaces are brought together. However, the aggregates are easily deformed, partly rearranged into multilayer structures and partly removed from between the surfaces under high loads. These layers offer very low friction coefficient (<0.01), high load bearing capacity (≈23MPa), and self-healing ability. Surface bound DPPC/hyaluronan aggregates provide a means for accumulation of lubricating DPPC molecules on sliding surfaces

    Radiofrequency induced heating of biodegradable orthopaedic screw implants during magnetic resonance imaging

    Get PDF
    Magnesium (Mg)-based implants have re-emerged in orthopaedic surgery as an alternative to permanent implants. Literature reveals little information on how the degradation of biodegradable implants may introduce safety implications for patient follow-up using medical imaging. Magnetic resonance imaging (MRI) benefits post-surgery monitoring of bone healing and implantation sites. Previous studies demonstrated radiofrequency (RF) heating of permanent implants caused by electromagnetic fields used in MRI. Our investigation is the first to report the effect of the degradation layer on RF-induced heating of biodegradable orthopaedic implants. WE43 orthopaedic compression screws underwent in vitro degradation. Imaging techniques were applied to assess the corrosion process and the material composition of the degraded screws. Temperature measurements were performed to quantify implant heating with respect to the degradation layer. For comparison, a commercial titanium implant screw was used. Strongest RF induced heating was observed for non-degraded WE43 screw samples. Implant heating had shown to decrease with the formation of the degradation layer. No statistical differences were observed for heating of the non-degraded WE43 material and the titanium equivalent. The highest risk of implant RF heating is most pronounced for Mg-based screws prior to degradation. Amendment to industry standards for MRI safety assessment is warranted to include biodegradable materials

    Classifying condition of ultra-high-molecular-weight polyethylene ropes with wide-angle X-ray scattering

    No full text
    Ropes of ultra-high-molecular-weight polyethylene (UHMWPE) are replacing steel wires in many applications and nondestructive testing to monitor their condition is of scientific and commercial interest. In this work, wide-angle X-ray scattering (WAXS) combined with linear discriminant analysis (LDA) is proposed as classification method to distinguish between healthy and damaged UHMWPE ropes. Healthy (as produced, after pre-stretching) and damaged (in-field use) ropes (⌀=22mm)(⌀ = 22 mm) have been analyzed using synchrotron radiation. Firstly, it is demonstrated that scans of healthy and damaged ropes can be distinguished with 100% cross-validated test classification accuracy using LDA; this is shown both with the input data consisting of pre-processed 1D WAXS data and with physical parameters retrieved by fitting the WAXS data. Secondly, it is demonstrated that the classification performance is similar using the two forms of input data and that the noise could be increased by a factor of three while maintaining 100% test classification accuracy across all the three cross-validation folds

    Early Osteoimmunomodulatory Effects of Magnesium–Calcium–Zinc alloys

    No full text
    Today, substantial attention is given to biomaterial strategies for bone regeneration, and among them, there is a growing interest in using immunomodulatory biomaterials. The ability of a biomaterial to induce neo vascularization and macrophage polarization is a major factor in defining its success. Magnesium (Mg)-based degradable alloys have attracted significant attention for bone regeneration owing to their biodegradability and potential for avoiding secondary removal surgeries. However, there is insufficient evidence in the literature regarding the early inflammatory responses to these alloys in vivo. In this study, we investigated the early body responses to Mg-0.45wt%Zn-0.45wt%Ca pin-shaped alloy (known as ZX00 alloy) in rat femora 2, 5, and 10 days after implantation. We used 3D micro computed tomography (µCT), histological, immunohistochemical, histomorphometrical, and small angle X-ray scattering (SAXS) analyses to study new bone formation, early macrophage polarization, neo vascularization, and bone quality at the implant bone interface. The expression of macrophage type 2 biological markers increased significantly after 10 days of Mg alloy implantation, indicating its potential in stimulating macrophage polarization. Our biomineralization results using µCT as well as histological stained sections did not indicate any statistically significant differences between different time points for both groups. The activity of alkaline phosphatase (ALP) and Runt-related transcription factor 2 (Runx 2) biological markers decreased significantly for Mg group, indicating less osteoblast activity. Generally, our results supported the potential of ZX00 alloy to enhance the expression of macrophage polarization in vivo; however, we could not observe any statistically significant changes regarding biomineralization

    Multiscale morphological analysis of bone microarchitecture around Mg-10Gd implants

    No full text
    The utilization of biodegradable magnesium (Mg)-based implants for restoration of bone function following trauma represents a transformative approach in orthopaedic application. One such alloy, magnesium-10 weight percent gadolinium (Mg-10Gd), has been specifically developed to address the rapid degradation of Mg while enhancing its mechanical properties to promote bone healing. Previous studies have demonstrated that Mg-10Gd exhibits favorable osseointegration; however, it exhibits distinct ultrastructural adaptation in comparison to conventional implants like titanium (Ti). A crucial aspect that remains unexplored is the impact of Mg-10Gd degradation on the bone microarchitecture. To address this, we employed hierarchical three-dimensional imaging using synchrotron radiation in conjunction with image-based finite element modelling. By using the methods outlined, the vascular porosity, lacunar porosity and the lacunar-canaliculi network (LCN) morphology of bone around Mg-10Gd in comparison to Ti in a rat model from 4 weeks to 20 weeks post-implantation was investigated. Our investigation revealed that within our observation period, the degradation of Mg-10Gd implants was associated with significantly lower (p < 0.05) lacunar density in the surrounding bone, compared to Ti. Remarkably, the LCN morphology and the fluid flow analysis did not significantly differ for both implant types. In summary, a more pronounced lower lacunae distribution rather than their morphological changes was detected in the surrounding bone upon the degradation of Mg-10Gd implants. This implies potential disparities in bone remodelling rates when compared to Ti implants. Our findings shed light on the intricate relationship between Mg-10Gd degradation and bone microarchitecture, contributing to a deeper understanding of the implications for successful osseointegration

    High-resolution ex vivo analysis of the degradation and osseointegration of Mg-xGd implant screws in 3D

    No full text
    Biodegradable magnesium (Mg) alloys can revolutionize osteosynthesis, because they have mechanical properties similar to those of the bone, and degrade over time, avoiding the need of removal surgery. However, they are not yet routinely applied because their degradation behavior is not fully understood. In this study we have investigated and quantified the degradation and osseointegration behavior of two biodegradable Mg alloys based on gadolinium (Gd) at high resolution. Mg-5Gd and Mg-10Gd screws were inserted in rat tibia for 4, 8 and 12 weeks. Afterward, the degradation rate and degradation homogeneity, as well as bone-to-implant interface, were studied with synchrotron radiation micro computed tomography and histology. Titanium (Ti) and polyether ether ketone (PEEK) were used as controls material to evaluate osseointegration. Our results showed that Mg-5Gd degraded faster and less homogeneously than Mg-10Gd. Both alloys gradually form a stable degradation layer at the interface and were surrounded by new bone tissue. The results were correlated to in vitro data obtained from the same material and shape. The average bone-to-implant contact of the Mg-xGd implants was comparable to that of Ti and higher than for PEEK. The results suggest that both Mg-xGd alloys are suitable as materials for bone implants

    Radiofrequency induced heating of biodegradable orthopaedic screw implants during magnetic resonance imaging

    Get PDF
    Magnesium (Mg)-based implants have re-emerged in orthopaedic surgery as an alternative to permanent implants. Literature reveals little information on how the degradation of biodegradable implants may introduce safety implications for patient follow-up using medical imaging. Magnetic resonance imaging (MRI) benefits post-surgery monitoring of bone healing and implantation sites. Previous studies demonstrated radiofrequency (RF) heating of permanent implants caused by electromagnetic fields used in MRI. Our investigation is the first to report the effect of the degradation layer on RF-induced heating of biodegradable orthopaedic implants.WE43 orthopaedic compression screws underwent in vitro degradation. Imaging techniques were applied to assess the corrosion process and the material composition of the degraded screws. Temperature measurements were performed to quantify implant heating with respect to the degradation layer. For comparison, a commercial titanium implant screw was used.Strongest RF induced heating was observed for non-degraded WE43 screw samples. Implant heating had shown to decrease with the formation of the degradation layer. No statistical differences were observed for heating of the non-degraded WE43 material and the titanium equivalent. The highest risk of implant RF heating is most pronounced for Mg-based screws prior to degradation. Amendment to industry standards for MRI safety assessment is warranted to include biodegradable materials

    Different Breathing Mechanisms in Flexible Pillared-Layered Metal–Organic Frameworks: Impact of the Metal Center

    No full text
    The pillared-layered metal–organic framework compounds M<sub>2</sub>(BME-bdc)<sub>2</sub>(dabco) (M<sup>2+</sup> = Zn<sup>2+</sup>, Co<sup>2+</sup>, Ni<sup>2+</sup>, Cu<sup>2+</sup>; BME-bdc<sup>2–</sup> = 2,5-bis­(2-methoxyethoxy)-1,4-benzenedicarboxylate; dabco = diazabicyclo[2.2.2]­octane) exhibit structural flexibility and undergo guest and temperature-induced reversible phase transitions between a narrow pore (<b>np</b>) and a large pore (<b>lp</b>) form. These transitions were analyzed in detail by powder X-ray diffraction <i>ex</i> and in situ, isothermal gas adsorption measurements and differential scanning calorimetry. The threshold parameters (gas pressure or temperature), the magnitude of the phase transitions (volume change) as well as their transition enthalpies are strikingly dependent on the chosen metal cation M<sup>2+</sup>. This observation is assigned to the different electronic structures and ligand field effects on the coordination bonds. Accordingly, in situ powder X-ray diffraction measurements as a function of CO<sub>2</sub> pressure reveal different mechanisms for the <b>np</b> to <b>lp</b> phase transition during CO<sub>2</sub> adsorption

    Intrinsically disordered peptides enhance regenerative capacities of bone composite xenografts

    No full text
    Biomaterial scientists design organic bone substitutes based on the biochemical properties of the mimicked tissue to achieve near native functionality. Several non-collagenous proteins in bone are known as intrinsically disordered proteins (IDPs), as they lack detectible ordered domains and a fixed 3D structure under physiological conditions. Many IDPs perform regulatory roles in a range of cellular functions, which motivated us to design two proline-rich disordered peptides (P2 and P6) and augmented them into the SmartBone® (SBN) biohybrid substitute. Recently we reported an improved proliferation and osteogensis of human osteoblasts and mesenchymal stem cells in the composite groups containing peptides (named here as SBN + P2 and SBN + P6) in vitro. To address the effects of these composites on bone formation and biomineralization, this in vivo study investigated their functions in critical size craniotomy defects in 16 domestic pigs after 8 and 16 weeks of healing. For this purpose, we used cone beam computed tomography (CBCT), microCT (µCT), histology, immunohistochemistry, fluorescent labeling of abundant reactive entities (FLARE), synchrotron SAXS/XRD, optical photothermal IR (O-PTIR) microscopy and nanoscale atomic force microscopy-infrared (AFM-IR) analyses. Our results represent new synthetic IDPs as potential candidates for directing bone formation and biomineralization. The SBN + P6 stimulated significantly higher bone formation and biomineralization after 8 weeks of healing compared to other groups indicating its potential in stimulating early biomineralization. After 16 weeks of healing, the SBN + P2 induced significantly higher bone formation and biomineralization compared to other groups indicating its effects on later bone formation and biomineralization processes. The vigorous stretching of amide primary and secondary IR absorbance peaks at 1660 and 1546 cm−1 in the SBN + P2 group verified that this peptide experienced more conformational changes after 16 weeks of implantation with a higher phosphate intensity at 1037 cm−1 compared to peptide 6. Overall, P2 and P6 are promising candidates for bone augmentation strategies in critical clinical applications. We concluded that FLARE and O-PTIR are promising tools in evaluating and diagnosing the biochemical structure of bone tissue and the bone-biomaterial interface
    corecore