31 research outputs found

    Baseline structural characteristics of the optic nerve head and retinal nerve fiber layer are associated with progressive visual field loss in patients with open-angle glaucoma

    Get PDF
    Aims To examine the relationship between baseline structural characteristics of the optic nerve head (ONH) and retinal nerve fiber layer (RNFL) and functional disease progression in patients with open-angle glaucoma (OAG) over 5 years. Methods 112 OAG patients were prospectively examined at baseline and every 6 months over a period of five years. Structural glaucomatous changes were examined with optical coherence tomography (OCT) and Heidelberg retinal tomography-III (HRT-III), and functional disease progression with automated perimetry (Humphrey visual fields). Cox proportional hazard models were used to assess the relationship between baseline structural measurements and functional disease progression. Results From baseline over a 5-year period, statistically significant increases were found in OCT disc (D) area (p<0.001), cup (C) area (p<0.001), C/D area ratio (p<0.001), C/D horizontal ratio (p<0.001), C/D vertical ratio (p = 0.018), and a decrease in superior RNFL thickness (p = 0.008). Statistically significant increases were found in HRT-III C volume (p = 0.021), C/D area ratio (p = 0.046), mean C depth (p = 0.036), C shape (p = 0.008), and height variation contour (p = 0.020). Functional disease progression was detected in 37 of the 112 patients (26 of European descent and 11 of African descent; 33%). A statistically significant shorter time to functional progression was seen in patients with larger baseline OCT D area (p = 0.008), C area (p = 0.003), thicker temporal RNFL (p = 0.003), and in patients with a larger HRT-III C area (p = 0.004), C/D area ratio (p = 0.004), linear C/D ratio (p = 0.007), C shape (p = 0.032), or smaller rim area (p = 0.039), rim volume (p = 0.005), height variation contour (p = 0.041), mean RNFL thickness (p<0.001), or RNFL cross-sectional area (p = 0.002). Conclusion Baseline ONH and RNFL structural characteristics were associated with a significantly shorter time to functional glaucomatous progression and visual field loss through the five-year period in OAG patients

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Diagnostic laboratory standardization and validation of platelet transmission electron microscopy

    No full text
    <p>Platelet transmission electron microscopy (PTEM) is considered the gold standard test for assessing distinct ultrastructural abnormalities in inherited platelet disorders (IPDs). Nevertheless, PTEM remains mainly a research tool due to the lack of standardized procedures, a validated dense granule (DG) count reference range, and standardized image interpretation criteria. The aim of this study was to standardize and validate PTEM as a clinical laboratory test. Based on previously established methods, we optimized and standardized preanalytical, analytical, and postanalytical procedures for both whole mount (WM) and thin section (TS) PTEM. Mean number of DG/platelet (plt), percentage of plts without DG, platelet count (PC), mean platelet volume (MPV), immature platelet fraction (IPF), and plt light transmission aggregometry analyses were measured on blood samples from 113 healthy donors. Quantile regression was used to estimate the reference range for DG/plt, and linear regression was used to assess the association of DG/plt with other plt measurements. All PTEM procedures were standardized using commercially available materials and reagents. DG interpretation criteria were established based on previous publications and expert consensus, and resulted in improved operator agreement. Mean DG/plt was stable for 2 days after blood sample collection. The median within patient coefficient of variation for mean DG/plt was 22.2%; the mean DG/plt reference range (mid-95th %) was 1.2–4.0. Mean DG/plt was associated with IPF (<i>p </i>= .01, R<sup>2</sup> = 0.06) but not age, sex, PC, MPV, or plt maximum aggregation or primary slope of aggregation (<i>p </i>> .17, R<sup>2</sup> < 0.02). Baseline ultrastructural features were established for TS-PTEM. PTEM was validated using samples from patients with previously established diagnoses of IPDs. Standardization and validation of PTEM procedures and interpretation, and establishment of the normal mean DG/plt reference range and PTEM baseline ultrastructural features, will facilitate implementation of PTEM as a valid clinical laboratory test for evaluating ultrastructural abnormalities in IPDs.</p
    corecore