106 research outputs found

    Computer assisted ocular pathology search

    Get PDF
    Computer assisted ocular pathology searc

    Effect of the Affordable Care Act Medicaid Expansion on Labor Participation of Female Registered Nurses in Outpatient Care

    Full text link
    Medicaid expansions were used to examine the effects of a surge in demand for primary care on the labor participation of registered nurses (RN) in outpatient settings relative to hospitals. Using difference-in-differences and two-way fixed effects with the American Community Survey Public Use Microdata Sample single-year 2010 through 2017 files, I find an increase in the probability of an RN working in an outpatient setting among (1) young, unmarried RNs with a maximum household income of 501 percent of the federal poverty level and (2) young unmarried RNs who have at least one child under age 6. These results are consistent with relatively high hospital turnover rates and strong labor force attachment among RNs in these demographic groups

    Time Course Of Substance P Expression In Dorsal Root Ganglia Following Complete Spinal Nerve Transection

    Get PDF
    Recent evidence suggests that substance P (SP) is upregulated in primary sensory neurons following axotomy, and that this change occurs in larger neurons that do not usually produce SP. If so, this upregulation may allow normally neighboring, uninjured, and non-nociceptive dorsal root ganglion (DRG) neurons to become effective in activating pain pathways. Using immunohistochemistry, we performed a unilateral L5 spinal nerve transection upon male Wistar rats, and measured SP expression in ipsilateral L4 and L5 DRGs and contralateral L5 DRGs, at 1 to 14 days postoperatively (dpo), and in control and sham operated rats. In normal and sham operated DRGs, SP was detectable almost exclusively in small neurons (≤ 800 μm2). Following surgery, the mean size of SP-positive neurons from the axotomized L5 ganglia was greater at 2, 4, 7 and 14 dpo. Among large neurons (\u3e 800 μm2) from the axotomized L5, the percentage of SPpositive neurons increased at 2, 4, 7, and 14 dpo. Among small neurons from the axotomized L5, the percentage of SP-positive neurons was increased at 1 and 3 dpo, but was decreased at 7 and 14 dpo. Thus, SP expression is affected by axonal damage, and the time course of the expression is different between large and small DRG neurons. These data support a role of SP-producing, large DRG neurons in persistent sensory changes due to nerve injury

    Coronary evaginations and peri-scaffold aneurysms following implantation of bioresorbable scaffolds: incidence, outcome, and optical coherence tomography analysis of possible mechanisms

    Get PDF
    Background Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS).Methods and results One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 diabetics) were analysed with angiography and optical coherence tomography (OCT) 12 months after implantation. Evaginations were identified as any hollow in the luminal vessel contour between well-apposed struts and were classified as major when extending ≥3 mm with a depth ≥10% of the BVS diameter. Fifty-five (54%) of the BVS (50(56%) of the patients) had at least one evagination (6.1 ± 6.2 evaginations per BVS), with a mean volume of 1.9 ± 1.9 mm³. Major evaginations were only found in one patient, and in-BVS aneurysms in three patients (4BVS). The presence of evaginations was strongly associated with that of malapposition (P = 0.003) and strut fractures (P = 0.01). No association could be shown between the presence and volume of the evaginations and any clinical variable or the presence of uncovered struts (P > 0.5). Peri-strut low- intensity areas (PSLIA) were present in 29 (53%) of the BVS with evaginations and 12 (26%) of those without (P = 0.0049); their presence was independently associated with the presence, the number (P P = 0.004) and with that of strut fracture. Conclusions Optical coherence tomography-detected evaginations are relatively common after BVS implantation, but, as for modern drug-eluting metallic stents, major evaginations are very rare. Optical coherence tomography evidence of immature neointima and strut fractures were associated with more severe development of evaginations

    Three-years outcomes of diabetic patients treated with coronary bioresorbable scaffolds

    Get PDF
    Background: Diabetes is among the strongest predictors of outcome after coronary artery stenting and the incidence of negative outcomes is still high in this specific group. Data of long-term outcomes comparing diabetic patients with non-diabetic patients treated with bioresorbable scaffolds are still incomplete. This work evaluates the long-term outcomes after implantation of a coronary bioresorbable scaffold (BRS) in diabetic patients compared to non-diabetics. Methods: Patients who received at least one Absorb BRS in the time of May 2012 to December 2014 were enrolled into this single-center registry. Quantitative coronary angiography (QCA) was performed. Results: Six hundred fifty seven patients including 138 patients (21%, mean age 65 ± 11, 78% male) with Diabetes were enrolled. Patients in the diabetic group were significantly older, were more likely to suffer from hypertension and hyperlipidemia and had more often a prior stroke or TIA as well as a reduced renal function (all P < 0.05). The initial stenosis was less severe in the diabetic group (74.8% vs. 79.6%, P = 0.036), but the residual stenosis after BRS implantation exceeded that of the control group (16.7% vs. 13.8%, P = 0.006). History of diabetes had no impact on the incidence of events within one year after BRS implantation. Beyond 1 year, diabetic patients had a higher incidence of cardiovascular death (6.9 vs. 1.4%, HR:5.37 [1.33–21.71], P = 0.001), scaffold restenosis (17.6 vs. 7.8%, HR:3.56 [1.40–9.05], P < 0.0001) and target lesion revascularization (P = 0.016). These results were confirmed in the propensity score analysis. In both diabetics and non-diabetics, there was a strong association (HR:18.6 [4.7–73.3]) between the risk of restenosis and the technique used at implantation; in contrast, the impact of vessel size was more manifest in nondiabetics than in diabetic patients, and an increased risk of restenosis was demonstrated for both large and small vessels. Conclusion: As for metal stents, beyond one year after implantation, diabetes was associated with an increased incidence of scaffold restenosis and related outcomes. This negative impact of diabetes was reset when an optimal implantation technique was used. Keywords: Diabetes, Bioresorbable scaffolds, Coronary artery diseas

    Optical coherence tomography findings in bioresorbable vascular scaffolds thrombosis

    Get PDF
    Background—Everolimus-eluting bioresorbable vascular scaffolds have been developed to improve late outcomes after coronary interventions. However, recent registries raised concerns regarding an increased incidence of scaffold thrombosis (ScT). The mechanism of ScT remains unknown.Methods and Results—The present study investigated angiographic and optical coherence tomography findings in patients experiencing ScT. Fifteen ScT (14 patients, 79% male, age 59±10 years) occurred at a median of 16 days (25%–75% interquartile range: 1–263 days) after implantation. Early ScT (1 month) and very late (>1 year) ScT (respectively, 5 and 2 cases), 5 scaffolds showed intimal neovessels or marked peristrut low-intensity areas. Scaffold fractures were additionally found in 2 patients, and scaffold collapse was found in 1 patient with very late ScT. Extensive strut malapposition was the presumed cause for ScT in 1 case. One scaffold did not show any morphological abnormality. Thrombectomy specimens were analyzed in 3 patients and did not demonstrate increased numbers of inflammatory cells.Conclusions—The mechanisms of early ScT seem to be similar to metallic stents (mechanical and inadequate antiplatelet therapy). The predominant finding in late and very late ScT is peristrut low-intensity area

    Bioresorbable coronary scaffold thrombosis: multicenter comprehensive analysis of clinical presentation, mechanisms, and predictors

    Get PDF
    Background Recent reports suggest an elevated incidence of bioresorbable vascular scaffold (BVS) thrombosis (scaffold thrombosis [ScT]).Objectives This study investigated occurrence rates, clinical and angiographic characteristics, and possible mechanisms of ScT in all-comer patients undergoing BVS implantation at 2 German and 2 Swiss hospitals.Methods A total of 1,305 consecutive patients (mean age 64 years, 78% male) who received 1,870 BVS (mean 1.4 ± 0.8 BVS/patient) were enrolled. Clinical/procedural characteristics, mortality, and ScT data at 485 days (range 312 to 652 days) were examined.Results ScT occurred in 42 patients. The incidence of probable and definite ScT was 1.8% at 30 days and 3.0% at 12 months, without differences among centers (p = 0.60). A total of 22 (52%) ScTs presented as ST-segment elevation myocardial infarction and 6 (17%) as sudden cardiac death. In multivariable analysis, ostial lesions (p = 0.049) and impaired left ventricular ejection fraction (p = 0.019) were independently associated with ScT. Nine (21%) of the ScTs occurred in patients who had suspended dual antiplatelet therapy, in 6 cases prematurely. Lower post-procedural minimum lumen and reference vessel diameters were hallmarks of ScT (all p < 0.0001). The risk of ScT appeared to rapidly increase for post-procedural minimum lumen diameters below 2.4 mm (for the 2.5- to 3.0-mm BVS) and 2.8 mm (for the 3.5-mm BVS). When a BVS-specific implantation strategy was implemented, 12-month ScT rates fell from 3.3% to 1.0%, an effect that remained significant when adjusted for multivariable propensity score (p = 0.012; hazard ratio: 0.19; 95% confidence interval: 0.05 to 0.70).Conclusions The 12-month incidence of ScT reached 3% and could be significantly reduced when an optimized implantation strategy was employed. (retrospective multicentric registry and Mainz Intracoronary Database. The Coronary Slow-flow and Microvascular Diseases Registry [MICAT]; NCT02180178

    Coronary stent strut fractures: classification, prevalence and clinical associations

    Get PDF
    Introduction. The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results. A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%); two or more stacked struts (23%); deformation without gap (27%); transection (9%). In multivariable analysis, calcific and bifurcation lesions were associated with SF in DES (OR: 3.5 [1.1-11] and 4.0 [2.2-7.2], p < 0.05). Device eccentricity and asymmetry as well as optical coherence tomography (OCT) features of impaired strut healing were also associated with SF. The prevalence of fractures was similar in a set of 289 bioresorbable scaffolds (BRS). In a separate series of 20 device thromboses and 36 device restenoses, the prevalence of SF was higher (61.2% of DES and 66.7% of BRS, p < 0.001 for both), with a higher frequency of complex SF patterns (p < 0.0001). In logistic regression analysis, fractures were a correlate of device complications (p < 0.0001, OR = 24.9 [5.6-111] for DES and OR = 6.0 [1.8-20] for BRS). Discussion. The prevalence of OCT-diagnosed SF was unexpectedly high in the setting of elective controls and it increased by about three-fold in the setting of device failure. Fractures were associated with increased lesion complexity and device asymmetry/eccentricity and were more frequent in the setting of device failure such as restenosis and thrombosis.Cardiovascular Aspects of Radiolog

    Visuospatial Integration: Paleoanthropological and Archaeological Perspectives

    Get PDF
    The visuospatial system integrates inner and outer functional processes, organizing spatial, temporal, and social interactions between the brain, body, and environment. These processes involve sensorimotor networks like the eye–hand circuit, which is especially important to primates, given their reliance on vision and touch as primary sensory modalities and the use of the hands in social and environmental interactions. At the same time, visuospatial cognition is intimately connected with memory, self-awareness, and simulation capacity. In the present article, we review issues associated with investigating visuospatial integration in extinct human groups through the use of anatomical and behavioral data gleaned from the paleontological and archaeological records. In modern humans, paleoneurological analyses have demonstrated noticeable and unique morphological changes in the parietal cortex, a region crucial to visuospatial management. Archaeological data provides information on hand–tool interaction, the spatial behavior of past populations, and their interaction with the environment. Visuospatial integration may represent a critical bridge between extended cognition, self-awareness, and social perception. As such, visuospatial functions are relevant to the hypothesis that human evolution is characterized by changes in brain–body–environment interactions and relations, which enhance integration between internal and external cognitive components through neural plasticity and the development of a specialized embodiment capacity. We therefore advocate the investigation of visuospatial functions in past populations through the paleoneurological study of anatomical elements and archaeological analysis of visuospatial behaviors
    • …
    corecore