129 research outputs found

    Joint-preserving surgical treatment options for irreparable posterosuperior rotator cuff tear : Partial repair, superior capsular reconstruction, latissimus dorsi, lower trapezius, or a balloon?

    Full text link
    Treatment of irreparable rotator cuff tears in young active patients is challenging. A variety of therapeutic options are available. Only a few joint-preserving treatment options show reliable improvements over a long-term follow-up period. However, the treatment outcomes of joint preservation procedures are not comparable to those of RTSA, as patients are typically younger and have higher expectations. It is remarkable that most of the joint-preserving therapeutic options for irreparable rotator cuff ruptures lack long-term treatment results. This article highlights the indications, technical aspects, and treatment outcomes of the most commonly performed joint-preserving surgeries for irreparable rotator cuff rupture. = Die Behandlung der irreparablen posterosuperioren Rotatorenmanschettenruptur bei jungen, aktiven Patienten stellt eine Herausforderung dar. Es bestehen verschiedene Therapieoptionen. Nur vereinzelte gelenkserhaltende Therapieoptionen zeigen über einen langen Nachkontrollzeitraum verlässliche Verbesserungen der Schulterfunktion und Patientenzufriedenheit. Die Behandlungsergebnisse der gelenkserhaltenden Operationen sind jedoch nicht mit jenen der RTSA vergleichbar, da die Patienten typischerweise jünger sind und höhere Ansprüche haben. Bemerkenswert ist, dass zu den meisten gelenkerhaltenden Eingriffen bei irreparablen Rotatorenmanschettenrupturen Langzeittherapieergebnisse fehlen. In dieser Übersichtsarbeit werden die am häufigsten vorgenommenen gelenkerhaltenden Eingriffe hinsichtlich Indikationen, technischer Aspekte und Behandlungsresultaten beleuchtet

    In-vivo glenohumeral translation and ligament elongation during abduction and abduction with internal and external rotation

    Get PDF
    Study Design: Basic Science. To investigate humeral head translations and glenohumeral ligament elongation with a dual fluoroscopic imaging system. Background: The glenohumeral ligaments are partially responsible for restraining the humeral head during the extremes of shoulder motion. However, in-vivo glenohumeral ligaments elongation patterns have yet to be determined. Therefore, the objectives of this study were to 1) quantify the in-vivo humeral head translations and glenohumeral ligament elongations during functional shoulder positions, 2) compare the inferred glenohumeral ligament functions with previous literature and 3) create a baseline data of healthy adult shoulder glenohumeral ligament lengths as controls for future studies. Methods: Five healthy adult shoulders were studied with a validated dual fluoroscopic imaging system (DFIS) and MR imaging technique. Humeral head translations and the superior, middle and inferior glenohumeral ligaments (SGHL, MGHL, IGHL) elongations were determined. Results: The humeral head center on average translated in a range of 6.0mm in the anterior-posterior direction and 2.5mm in the superior-inferior direction. The MGHL showed greater elongation over a broader range of shoulder motion than the SGHL. The anterior-band (AB)-IGHL showed maximum elongation at 90° abduction with maximum external rotation. The posterior-band (PB)-IGHL showed maximum elongation at 90° abduction with maximum internal rotation. Discussion: The results demonstrated that the humeral head translated statistically more in the anterior-posterior direction than the superior-inferior direction (p = 0.01), which supports the concept that glenohumeral kinematics are not ball-in-socket mechanics. The AB-IGHL elongation pattern makes it an important static structure to restrain anterior subluxation of the humeral head during the externally rotated cocking phase of throwing motion. These data suggest that in healthy adult shoulders the ligamentous structures of the glenohumeral joint are not fully elongated in many shoulder positions, but function as restraints at the extremes of glenohumeral motion. Clinically, these results may be helpful in restoring ligament anatomy during the treatment of anterior instability of the shoulder

    Improved PCR based methods for detecting C9orf72 hexanucleotide repeat expansions

    Get PDF
    Due to the GC-rich, repetitive nature of C9orf72 hexanucleotide repeat expansions, PCR based detection methods are challenging. Several limitations of PCR have been reported and overcoming these could help to define the pathogenic range. There is also a need to develop improved repeat-primed PCR assays which allow detection even in the presence of genomic variation around the repeat region. We have optimised PCR conditions for the C9orf72 hexanucleotide repeat expansion, using betaine as a co-solvent and specific cycling conditions, including slow ramping and a high denaturation temperature. We have developed a flanking assay, and repeat-primed PCR assays for both 3′ and 5′ ends of the repeat expansion, which when used together provide a robust strategy for detecting the presence or absence of expansions greater than ∼100 repeats, even in the presence of genomic variability at the 3′ end of the repeat. Using our assays, we have detected repeat expansions in 47/442 Scottish ALS patients. Furthermore, we recommend the combined use of these assays in a clinical diagnostic setting

    Interference Screw vs. Suture Anchor Fixation for Open Subpectoral Biceps Tenodesis: Does it Matter?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Bioabsorbable interference screw fixation has superior biomechanical properties compared to suture anchor fixation for biceps tenodesis. However, it is unknown whether fixation technique influences clinical results.</p> <p>Hypothesis</p> <p>We hypothesize that subpectoral interference screw fixation offers relevant clinical advantages over suture anchor fixation for biceps tenodesis.</p> <p>Study Design</p> <p>Case Series.</p> <p>Methods</p> <p>We performed a retrospective review of a consecutive series of 88 patients receiving open subpectoral biceps tenodesis with either interference screw fixation (34 patients) or suture anchor fixation (54 patients). Average follow up was 13 months. Outcomes included Visual Analogue Pain Scale (0–10), ASES score, modified Constant score, pain at the tenodesis site, failure of fixation, cosmesis, deformity (popeye) and complications.</p> <p>Results</p> <p>There were no failures of fixation in this study. All patients showed significant improvement between their preoperative and postoperative status with regard to pain, ASES score, and abbreviated modified Constant scores. When comparing IF screw versus anchor outcomes, there was no statistical significance difference for VAS (p = 0.4), ASES score (p = 0.2), and modified Constant score (P = 0.09). One patient (3%) treated with IF screw complained of persistent bicipital groove tenderness, versus four patients (7%) in the SA group (nonsignificant).</p> <p>Conclusion</p> <p>Subpectoral biceps tenodesis reliably relieves pain and improves function. There was no statistically significant difference in the outcomes studied between the two fixation techniques. Residual pain at the site of tenodesis may be an issue when suture anchors are used in the subpectoral location.</p

    LSST: from Science Drivers to Reference Design and Anticipated Data Products

    Get PDF
    (Abridged) We describe here the most ambitious survey currently planned in the optical, the Large Synoptic Survey Telescope (LSST). A vast array of science will be enabled by a single wide-deep-fast sky survey, and LSST will have unique survey capability in the faint time domain. The LSST design is driven by four main science themes: probing dark energy and dark matter, taking an inventory of the Solar System, exploring the transient optical sky, and mapping the Milky Way. LSST will be a wide-field ground-based system sited at Cerro Pach\'{o}n in northern Chile. The telescope will have an 8.4 m (6.5 m effective) primary mirror, a 9.6 deg2^2 field of view, and a 3.2 Gigapixel camera. The standard observing sequence will consist of pairs of 15-second exposures in a given field, with two such visits in each pointing in a given night. With these repeats, the LSST system is capable of imaging about 10,000 square degrees of sky in a single filter in three nights. The typical 5σ\sigma point-source depth in a single visit in rr will be 24.5\sim 24.5 (AB). The project is in the construction phase and will begin regular survey operations by 2022. The survey area will be contained within 30,000 deg2^2 with δ<+34.5\delta<+34.5^\circ, and will be imaged multiple times in six bands, ugrizyugrizy, covering the wavelength range 320--1050 nm. About 90\% of the observing time will be devoted to a deep-wide-fast survey mode which will uniformly observe a 18,000 deg2^2 region about 800 times (summed over all six bands) during the anticipated 10 years of operations, and yield a coadded map to r27.5r\sim27.5. The remaining 10\% of the observing time will be allocated to projects such as a Very Deep and Fast time domain survey. The goal is to make LSST data products, including a relational database of about 32 trillion observations of 40 billion objects, available to the public and scientists around the world.Comment: 57 pages, 32 color figures, version with high-resolution figures available from https://www.lsst.org/overvie

    The CPLEAR detector at CERN

    Get PDF
    The CPLEAR collaboration has constructed a detector at CERN for an extensive programme of CP-, T- and CPT-symmetry studies using K0{\rm K}^0 and Kˉ0\bar{\rm K}^0 produced by the annihilation of pˉ\bar{\rm p}'s in a hydrogen gas target. The K0{\rm K}^0 and Kˉ0\bar{\rm K}^0 are identified by their companion products of the annihilation K±π{\rm K}^{\pm} \pi^{\mp} which are tracked with multiwire proportional chambers, drift chambers and streamer tubes. Particle identification is carried out with a liquid Cherenkov detector for fast separation of pions and kaons and with scintillators which allow the measurement of time of flight and energy loss. Photons are measured with a lead/gas sampling electromagnetic calorimeter. The required antiproton annihilation modes are selected by fast online processors using the tracking chamber and particle identification information. All the detectors are mounted in a 0.44 T uniform field of an axial solenoid of diameter 2 m and length 3.6 m to form a magnetic spectrometer capable of full on-line reconstruction and selection of events. The design, operating parameters and performance of the sub-detectors are described.

    Interobserver reliability of classification and characterization of proximal humeral fractures: a comparison of two and three-dimensional CT

    Full text link
    Interobserver reliability for the classification of proximal humeral fractures is limited. The aim of this study was to test the null hypothesis that interobserver reliability of the AO classification of proximal humeral fractures, the preferred treatment, and fracture characteristics is the same for two-dimensional (2-D) and three-dimensional (3-D) computed tomography (CT). Members of the Science of Variation Group--fully trained practicing orthopaedic and trauma surgeons from around the world--were randomized to evaluate radiographs and either 2-D CT or 3-D CT images of fifteen proximal humeral fractures via a web-based survey and respond to the following four questions: (1) Is the greater tuberosity displaced? (2) Is the humeral head split? (3) Is the arterial supply compromised? (4) Is the glenohumeral joint dislocated? They also classified the fracture according to the AO system and indicated their preferred treatment of the fracture (operative or nonoperative). Agreement among observers was assessed with use of the multirater kappa (&kappa;) measure. Interobserver reliability of the AO classification, fracture characteristics, and preferred treatment generally ranged from &quot;slight&quot; to &quot;fair.&quot; A few small but statistically significant differences were found. Observers randomized to the 2-D CT group had slightly but significantly better agreement on displacement of the greater tuberosity (&kappa; = 0.35 compared with 0.30, p &lt; 0.001) and on the AO classification (&kappa; = 0.18 compared with 0.17, p = 0.018). A subgroup analysis of the AO classification results revealed that shoulder and elbow surgeons, orthopaedic trauma surgeons, and surgeons in the United States had slightly greater reliability on 2-D CT, whereas surgeons in practice for ten years or less and surgeons from other subspecialties had slightly greater reliability on 3-D CT. Proximal humeral fracture classifications may be helpful conceptually, but they have poor interobserver reliability even when 3-D rather than 2-D CT is utilized. This may contribute to the similarly poor interobserver reliability that was observed for selection of the treatment for proximal humeral fractures. The lack of a reliable classification confounds efforts to compare the outcomes of treatment methods among different clinical trials and reports

    The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe

    Get PDF
    The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed plan for a world-class experiment dedicated to addressing these questions. LBNE is conceived around three central components: (1) a new, high-intensity neutrino source generated from a megawatt-class proton accelerator at Fermi National Accelerator Laboratory, (2) a near neutrino detector just downstream of the source, and (3) a massive liquid argon time-projection chamber deployed as a far detector deep underground at the Sanford Underground Research Facility. This facility, located at the site of the former Homestake Mine in Lead, South Dakota, is approximately 1,300 km from the neutrino source at Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino charge-parity symmetry violation and mass ordering effects. This ambitious yet cost-effective design incorporates scalability and flexibility and can accommodate a variety of upgrades and contributions. With its exceptional combination of experimental configuration, technical capabilities, and potential for transformative discoveries, LBNE promises to be a vital facility for the field of particle physics worldwide, providing physicists from around the globe with opportunities to collaborate in a twenty to thirty year program of exciting science. In this document we provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess.Comment: Major update of previous version. This is the reference document for LBNE science program and current status. Chapters 1, 3, and 9 provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess. 288 pages, 116 figure
    corecore