95 research outputs found

    Effects of long pulse width and high pulsing frequency on surface superhydrophobicity of polytetrafluoroethylene in quasi-direct-current plasma immersion ion implantation

    Get PDF
    Long pulse, high frequency quasi-direct-current (dc) oxygen plasma immersion ion implantation (PIII) is utilized to create a superhydrophobic polytetrafluoroethylene (PTFE) surface with a water contact angle of over 150°. This technique allows the use of a high duty cycle without deleterious effects such as extensive sample heating encountered in conventional PIII. Scanning electron microscopy images review submicrometer-nanometer structures on the PTFE surface after long pulse, high frequency PIII indicative of ion implantation. On the other hand, plasma modification is the dominant effect in short pulse, low frequency PIII. Quasi-dc PIII is demonstrated to offer adjustable synergistic plasma and ion beam effects. © 2009 American Institute of Physics.published_or_final_versio

    Microfluidic fabrication of polymeric core-shell microspheres for controlled release applications

    Get PDF
    Footnote in article: Paper submitted as part of the 3rd European Conference on Microfluidics ... 2012We report a facile and robust microfluidic method to fabricate polymeric core-shell microspheres as delivery vehicles for biomedical applications. The characteristics of core-shell microspheres can be precisely and easily tuned by manipulating the microfluidic double emulsion templates. The addition of a shell can significantly improve the versatility as well as functionality of these microspheres as delivery vehicles. We demonstrate that the nature of the shell material plays an important role in the properties of the core-shell delivery vehicles. The release kinetics is significantly influenced by the material of the shell and other characteristics such as the thickness. For example, by adding a poly(lactic-co-glycolic acid) (PLGA) shell to an alginate core, the encapsulation efficiency is enhanced and undesired leakage of hydrophilic actives is prevented. By contrast, adding an alginate shell to PLGA core can lead to a reduction of the initial release rate, thus extending the release period of hydrophobic actives. Microfluidic fabrication enables the generation of precisely controlled core-shell microspheres with a narrow size distribution, which enables the investigation of the relationship between the release kinetics of these microspheres and their characteristics. The approach of using core-shell particles as delivery vehicles creates new opportunities to customize the release kinetics of active ingredients. © 2013 AIP Publishing LLC.published_or_final_versio

    Droplet based microfluidic fabrication of designer microparticles for encapsulation applications

    Get PDF
    published_or_final_versio

    Magnesium plasma modified bone allograft for Large Bone Defect Treatment

    Get PDF
    Invited TalkBone allograft is the most widely accepted approach in treating patients suffering from large segmental bone defect regardless of the advancement of synthetic bone substitutes[ I, 2]. However, the long-term complications of allograft application in term of delayed union or even nonunion were reported due to the stringent sterilization process prior to clinical implantation[3, 4]. Our previous studies demonstrated that the incorporation of magnesium ions (Mg2+) into biomaterials could …postprin

    3D Porous Polycaprolactone-based Magnesium Scaffold for Bone Tissue Engineering

    Get PDF
    published_or_final_versio

    Helping cancer patients quit smoking using brief advice based on risk communication: A randomized controlled trial

    Get PDF
    This randomized controlled trial aimed to examine the effectiveness of a smoking cessation intervention using a risk communication approach. A total of 528 smoking cancer patients were randomly allocated either into an intervention group (n = 268) to receive brief advice based on risk communication by a nurse counselor or a control group (n = 260) to receive standard care. Subjects in both groups received a smoking cessation booklet. Patient follow-ups were at 1 week and at 1, 3, 6, 9 and 12 months. No significant differences were found in self-reported point-prevalence 7-day abstinence between the intervention and control groups at 6 months (15.7% vs 16.5%; OR 0.94, 95% CI 0.59-1.50). The rate of at least 50% self-reported reduction of smoking at 6 months, was higher in the intervention group than in the control group (16.8% vs 12.3%; OR 1.43, 95% CI 0.88-2.35). The biochemically validated quit rate at the 6-month follow-up was higher in the intervention group than in the control group (5.2% vs 3.8%; OR 1.38, 95% CI 0.60-3.16). These data suggest that advice based on risk communication was not effective for quitting but improved the rate of smoking reduction among smoking cancer patients.published_or_final_versio

    Real-space mapping of tailored sheet and edge plasmons in graphene nanoresonators

    Get PDF
    Plasmons in graphene nanoresonators have many potential applications in photonics and optoelectronics, including room-temperature infrared and terahertz photodetectors, sensors, reflect arrays or modulators1, 2, 3, 4, 5, 6, 7. The development of efficient devices will critically depend on precise knowledge and control of the plasmonic modes. Here, we use near-field microscopy8, 9, 10, 11 between λ0 = 10–12 μm to excite and image plasmons in tailored disk and rectangular graphene nanoresonators, and observe a rich variety of coexisting Fabry–Perot modes. Disentangling them by a theoretical analysis allows the identification of sheet and edge plasmons, the latter exhibiting mode volumes as small as 10−8λ03. By measuring the dispersion of the edge plasmons we corroborate their superior confinement compared with sheet plasmons, which among others could be applied for efficient 1D coupling of quantum emitters12. Our understanding of graphene plasmon images is a key to unprecedented in-depth analysis and verification of plasmonic functionalities in future flatland technologies.Peer ReviewedPostprint (author's final draft

    Graphene plasmonics

    Full text link
    Two rich and vibrant fields of investigation, graphene physics and plasmonics, strongly overlap. Not only does graphene possess intrinsic plasmons that are tunable and adjustable, but a combination of graphene with noble-metal nanostructures promises a variety of exciting applications for conventional plasmonics. The versatility of graphene means that graphene-based plasmonics may enable the manufacture of novel optical devices working in different frequency ranges, from terahertz to the visible, with extremely high speed, low driving voltage, low power consumption and compact sizes. Here we review the field emerging at the intersection of graphene physics and plasmonics.Comment: Review article; 12 pages, 6 figures, 99 references (final version available only at publisher's web site

    Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.

    Get PDF
    BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700
    corecore