112 research outputs found

    D-dimer and risk of thromboembolic and bleeding events in patients with atrial fibrillation - observations from the ARISTOTLE trial

    Get PDF
    BackgroundD-dimer is related to adverse outcomes in arterial and venous thromboembolic diseases. ObjectivesTo evaluate the predictive value of D-dimer level for stroke, other cardiovascular events, and bleeds, in patients with atrial fibrillation (AF) treated with oral anticoagulation with apixaban or warfarin; and to evaluate the relationship between the D-dimer levels at baseline and the treatment effect of apixaban vs. warfarin. MethodsIn the ARISTOTLE trial, 18201 patients with AF were randomized to apixaban or warfarin. D-dimer was analyzed in 14878 patients at randomization. The cohort was separated into two groups; not receiving vitaminK antagonist (VKA) treatment and receiving VKA treatment at randomization. ResultsHigher D-dimer levels were associated with increased frequencies of stroke or systemic embolism (hazard ratio [HR][Q4 vs. Q1]1.72, 95% confidence interval [CI]1.14-2.59, P=0.003), death (HR[Q4 vs. Q1]4.04, 95%CI3.06-5.33) and major bleeding (HR[Q4 vs. Q1]2.47, 95%CI1.77-3.45,

    X-ray in-line holography and holotomography at the NanoMAX beamline

    Get PDF
    Coherent X-ray imaging techniques, such as in-line holography, exploit the high brilliance provided by diffraction-limited storage rings to perform imaging sensitive to the electron density through contrast due to the phase shift, rather than conventional attenuation contrast. Thus, coherent X-ray imaging techniques enable high-sensitivity and low-dose imaging, especially for low-atomic-number (Z) chemical elements and materials with similar attenuation contrast. Here, the first implementation of in-line holography at the NanoMAX beamline is presented, which benefits from the exceptional focusing capabilities and the high brilliance provided by MAX IV, the first operational diffraction-limited storage ring up to approximately 300 eV. It is demonstrated that in-line holography at NanoMAX can provide 2D diffraction-limited images, where the achievable resolution is only limited by the 70 nm focal spot at 13 keV X-ray energy. Also, the 3D capabilities of this instrument are demonstrated by performing holotomography on a chalk sample at a mesoscale resolution of around 155 nm. It is foreseen that in-line holography will broaden the spectra of capabilities of MAX IV by providing fast 2D and 3D electron density images from mesoscale down to nanoscale resolution

    Repeated Measurements of Cardiac Biomarkers in Atrial Fibrillation and Validation of the ABC Stroke Score Over Time

    Get PDF
    Background--Cardiac biomarkers are independent risk markers in atrial fibrillation, and the novel biomarker-based ABC stroke score (age, biomarkers, and clinical history of prior stroke) was recently shown to improve the prediction of stroke risk in patients with atrial fibrillation. Our aim was to investigate the short-term variability of the cardiac biomarkers and evaluate whether the ABC stroke risk score provides a stable short- term risk estimate. Methods and Results--According to the study protocol, samples were obtained at entry and also at 2 months in 4796 patients with atrial fibrillation followed for a median of 1.8 years in the ARISTOTLE (Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation) trial. Cardiac troponin I, cardiac troponin T, and N-terminal pro-B-type natriuretic peptide were measured with high-sensitivity immunoassays. Associations with outcomes were evaluated by Cox regression. C indices and calibration plots were used to evaluate the ABC stroke score at 2 months. The average changes in biomarker levels during 2 months were small ( median change cardiac troponin T +2.8%, troponin I +2.0%, and N-terminal pro-B-type natriuretic peptide +13.5%) and within-subject correlation was high ( all >= 0.82). Repeated measurement of cardiac biomarkers provided some incremental prognostic value for mortality but not for stroke when combined with clinical risk factors and baseline levels of the biomarkers. Based on 8702 person-years of follow-up and 96 stroke/systemic embolic events, the ABC stroke score at 2 months achieved a similar C index of 0.70 (95% CI, 0.65-0.76) as compared with 0.70 (95% CI, 0.65-0.75) at baseline. The ABC stroke score remained well calibrated using predefined risk classes. Conclusions--In patients with stable atrial fibrillation, the variability of the cardiac biomarkers and the biomarker- based ABC stroke score during 2 months are small. The prognostic information by the ABC stroke score remains consistent and well calibrated with similar good predictive performance if patients are retested after 2 months. Clinical Trial Registration --URL: http://www.clinicaltrials.gov. Unique identifier: NCT00412984.Peer reviewe

    Left ventricular systolic dysfunction, heart failure, and the risk of stroke and systemic embolism in patients with atrial fibrillation : insights from the ARISTOTLE trial

    Get PDF
    We examined the risk of stroke or systemic embolism (SSE) conferred by heart failure (HF) and left ventricular systolic dysfunction (LVSD) in the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation Trial (ARISTOTLE), as well as the effect of apixaban versus warfarin

    Anemia is associated with bleeding and mortality, but not stroke, in patients with atrial fibrillation: Insights from the Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation (ARISTOTLE) trial

    Get PDF
    Background Patients with atrial fibrillation (AF) are prone to cardiovascular events and anticoagulation-related bleeding complications. We hypothesized that patients with anemia are at increased risk for these outcomes. Methods We performed a post hoc analysis of the ARISTOTLE trial, which included N 18,000 patients with AF randomized to warfarin (target international normalized ratio, 2.0-3.0) or apixaban 5 mg twice daily. Multivariable Cox regression analysis was used to determine if anemia (defined as hemoglobin b 13.0 in men and b 12.0 g/dL in women) was associated with future stroke, major bleeding, or mortality. Results Anemia was present at baseline in 12.6% of the ARISTOTLE population. Patients with anemia were older, had higher mean CHADS 2 and HAS-BLED scores, and were more likely to have experienced previous bleeding events. Anemia was associated with major bleeding (adjusted hazard ratio [HR], 1.92; 95% CI, 1.62-2.28; P b .0001) and all-cause mortality (adjusted HR, 1.68; 95% CI, 1.46-1.93; P b .0001) but not stroke or systemic embolism (adjusted HR, 0.92; 95% CI, 0.70- 1.21). The benefits of apixaban compared with warfarin on the rates of stroke, mortality, and bleeding events were consistent in patients with and without anemia. Conclusions Chronic anemia is associated with a higher incidence of bleeding complications and mortality, but not of stroke, in anticoagulated patients with AF. Apixaban is an attractive anticoagulant for stroke prevention in patients with AF with or without anemia. (Am Heart J 2017;185:140-9.

    Biomarkers and heart failure events in patients with atrial fibrillation in the ARISTOTLE trial evaluated by a multistate model

    Get PDF
    Background: Atrial fibrillation (AF) and heart failure (HF) often coexist. We investigated the prognostic impact of biomarkers on the development of HF and death in patients with AF and different left ventricular systolic function considering the influence of competing events. Methods: The study included 11,818 patients with AF from the ARISTOTLE trial who at entry had information on history of HF, an estimate of left ventricular function and plasma samples for determination of biomarkers representing cardiorenal dysfunction (NT-proBNP, troponin T, cystatin C) and inflammation (GDF-15, IL-6, CRP). Patients were categorized into: (I) HF with reduced ejection fraction (HFrEF, n=2,048), (II) HF with preserved ejection fraction (HFpEF, n=2,520), and (III) No HF (n=7,250). Biomarker associations with HF hospitalization and death were analyzed using a multi-state model accounting also for repeated events. Results: Baseline levels of NT-proBNP, troponin T, cystatin C, GDF-15, IL-6, and CRP were highest in HFrEF and lowest in No HF. During median 1.9 years follow-up, 546 patients were hospitalized at least once for HF and 819 died. Higher levels of all investigated biomarkers were associated with both outcomes (all p<0.0001), with highest event rates in HFrEF and lowest in No HF. The associations remained after adjustments and were more pronounced for first than for recurrent events. Conclusions: In anticoagulated patients with AF, biomarkers indicating cardiorenal dysfunction and inflammation improve the identification of patients at risk of developing HF or worsening of already existing HF. These biomarkers might be useful for targeting novel HF therapies in patients with AF

    Association between loop diuretic dose changes and outcomes in chronic heart failure: observations from the ESC-EORP Heart Failure Long-Term Registry

    Get PDF
    [Abstract] Aims. Guidelines recommend down-titration of loop diuretics (LD) once euvolaemia is achieved. In outpatients with heart failure (HF), we investigated LD dose changes in daily cardiology practice, agreement with guideline recommendations, predictors of successful LD down-titration and association between dose changes and outcomes. Methods and results. We included 8130 HF patients from the ESC-EORP Heart Failure Long-Term Registry. Among patients who had dose decreased, successful decrease was defined as the decrease not followed by death, HF hospitalization, New York Heart Association class deterioration, or subsequent increase in LD dose. Mean age was 66±13 years, 71% men, 62% HF with reduced ejection fraction, 19% HF with mid-range ejection fraction, 19% HF with preserved ejection fraction. Median [interquartile range (IQR)] LD dose was 40 (25–80) mg. LD dose was increased in 16%, decreased in 8.3% and unchanged in 76%. Median (IQR) follow-up was 372 (363–419) days. Diuretic dose increase (vs. no change) was associated with HF death [hazard ratio (HR) 1.53, 95% confidence interval (CI) 1.12–2.08; P = 0.008] and nominally with cardiovascular death (HR 1.25, 95% CI 0.96–1.63; P = 0.103). Decrease of diuretic dose (vs. no change) was associated with nominally lower HF (HR 0.59, 95% CI 0.33–1.07; P = 0.083) and cardiovascular mortality (HR 0.62 95% CI 0.38–1.00; P = 0.052). Among patients who had LD dose decreased, systolic blood pressure [odds ratio (OR) 1.11 per 10 mmHg increase, 95% CI 1.01–1.22; P = 0.032], and absence of (i) sleep apnoea (OR 0.24, 95% CI 0.09–0.69; P = 0.008), (ii) peripheral congestion (OR 0.48, 95% CI 0.29–0.80; P = 0.005), and (iii) moderate/severe mitral regurgitation (OR 0.57, 95% CI 0.37–0.87; P = 0.008) were independently associated with successful decrease. Conclusion. Diuretic dose was unchanged in 76% and decreased in 8.3% of outpatients with chronic HF. LD dose increase was associated with worse outcomes, while the LD dose decrease group showed a trend for better outcomes compared with the no-change group. Higher systolic blood pressure, and absence of (i) sleep apnoea, (ii) peripheral congestion, and (iii) moderate/severe mitral regurgitation were independently associated with successful dose decrease
    corecore