824 research outputs found

    The parent analogy: a reassessment

    Get PDF
    According to the parent analogy, as a caretaker’s goodness, ability and intelligence increase, the likelihood that the caretaker will make arrangements for the attainment of future goods that are unnoticed or underappreciated by their dependents also increases. Consequently, if this analogy accurately represents our relationship to God, then we should expect to find many instances of inscrutable evil in the world. This argument in support of skeptical theism has recently been criticized by Dougherty. I argue that Dougherty’s argument is incomplete, for there are two plausible ways of construing the parent analogy’s conclusion. I supplement Dougherty’s case by offering a new argument against the parent analogy based on failed expectations concerning the amount of inscrutable evils encountered in the world. Consequently, there remains a significant empirical hurdle for skeptical theism to overcome if it is to maintain its status as a defeater for our reliability when tracking gratuitous evils.Publisher PDFPeer reviewe

    Are Pfiesteria species toxicogenic? Evidence against production of ichthyotoxins by Pfiesteria shumwayae

    Get PDF
    The estuarine genus Pfiesteria has received considerable attention since it was first identified and proposed to be the causative agent of fish kills along the mid-Atlantic coast in 1992. The presumption has been that the mechanism of fish death is by release of one or more toxins by the dinoflagellate. In this report, we challenge the notion that Pfiesteria species produce ichthyotoxins. Specifically, we show that (i) simple centrifugation, with and without ultrasonication, is sufficient to detoxify water of actively fish-killing cultures of Pfiesteria shumwayae, (ii) organic extracts of lyophilized cultures are not toxic to fish, (fit) degenerate primers that amplify PKS genes from several polyketide-producing dinoflagellates failed to yield a product with A shumwayae DNA or cDNA, and (iv) degenerate primers for NRPS genes failed to amplify any NRPS genes but (unexpectedly) yielded a band (among several) that corresponded to known or putative PKSs and fatty acid synthases. We conclude that P. shumwayae is able to kill fish by means other than releasing a toxin into bulk water. Alternative explanations of the effects attributed to Pfiesteria are suggested

    The missense of smell: functional variability in the human odorant receptor repertoire.

    Get PDF
    Humans have ~400 intact odorant receptors, but each individual has a unique set of genetic variations that lead to variation in olfactory perception. We used a heterologous assay to determine how often genetic polymorphisms in odorant receptors alter receptor function. We identified agonists for 18 odorant receptors and found that 63% of the odorant receptors we examined had polymorphisms that altered in vitro function. On average, two individuals have functional differences at over 30% of their odorant receptor alleles. To show that these in vitro results are relevant to olfactory perception, we verified that variations in OR10G4 genotype explain over 15% of the observed variation in perceived intensity and over 10% of the observed variation in perceived valence for the high-affinity in vitro agonist guaiacol but do not explain phenotype variation for the lower-affinity agonists vanillin and ethyl vanillin

    A randomised trial into the effect of an isolated hip abductor strengthening programme and a functional motor control programme on knee kinematics and hip muscle strength

    Get PDF
    Background: Dynamic knee valgus and internal femoral rotation are proposed to be contributory risk factors for patellofemoral pain and anterior cruciate ligament injuries. Multimodal interventions including hip abductor strengthening or functional motor control programmes have a positive impact of pain, however their effect on knee kinematics and muscle strength is less clear. The aim of this study was to examine the effect of isolated hip abductor strengthening and a functional motor control exercise on knee kinematics and hip abductor strength. Methods: This prospective, randomised, repeated measures design included 29 asymptomatic volunteers presenting with increase knee valgus and femoral internal rotation. Participants completed either isolated hip abductor strengthening or a functional motor control exercise for 5 weeks. Knee kinematics were measured using inertial sensors during 2 functional activities and hip abductor strength measured using a load cell during isometric hip abduction. Results: There were no significant differences in dynamic knee valgus and internal rotation following the isolated hip abductor or functional motor control intervention, and no significant differences between the groups for knee angles. Despite this, the actual magnitude of reduction in valgus was 10° and 5° for the functional motor control group and strengthening group respectively. The actual magnitude of reduction in internal rotation was 9° and 18° for the functional motor control group and strengthening group respectively. Therefore there was a tendency towards clinically significant improvements in knee kinematics in both exercise groups. A statistically significant improvement in hip abductor strength was evident for the functional motor control group (27% increase; p = 0.008) and strengthening group (35% increase; p = 0.009) with no significant difference between the groups being identified (p = 0.475). Conclusions: Isolated hip strengthening and functional motor control exercises resulted in non-statistically significant changes in knee kinematics, however there was a clear trend towards clinically meaningful reductions in valgus and internal rotation. Both groups demonstrated similar significant gains in hip abductor strength suggesting\ud either approach could be used to strengthen the hip abductors

    Study of the Interactions of Ionic Liquids in IC by QSRR

    Get PDF
    The nature of ionic liquids (ILs) facilitates their analysis by ion chromatography which, unlike conventional high-performance liquid chromatography, enables analysis both of cations and anions. This paper describes a pioneering ion-chromatographic investigation of IL cations and statistical evaluation of quantitative structure–retention relationships with the objective of predicting the molecular mechanism responsible for retention. Eleven ionic liquid imidazolium and pyridinium cations were analyzed on a CS15 cation-exchange column by isocratic elution with acetonitrile–methanesulfonic acid mixtures. Structural descriptors of the cations obtained from molecular modeling were used to describe their hydrophobicity as determined by chromatography. The most statistically significant were three-term QSRR regression equations relating log kw to analyte n-octanol–water partition coefficient (log P), dipole moment (μ), solvent accessible surface area (ASAS), and hydration energy (HE). They indicate the important role of both hydrophobic and polar the retention of ILs on the CS15 column

    Skewed Distribution of Circulating Activated Natural Killer T (NKT) Cells in Patients with Common Variable Immunodeficiency Disorders (CVID)

    Get PDF
    Common variable immunodeficiency disorder (CVID) is the commonest cause of primary antibody failure in adults and children, and characterized clinically by recurrent bacterial infections and autoimmune manifestations. Several innate immune defects have been described in CVID, but no study has yet investigated the frequency, phenotype or function of the key regulatory cell population, natural killer T (NKT) cells. We measured the frequencies and subsets of NKT cells in patients with CVID and compared these to healthy controls. Our results show a skewing of NKT cell subsets, with CD4+ NKT cells at higher frequencies, and CD8+ NKT cells at lower frequencies. However, these cells were highly activated and expression CD161. The NKT cells had a higher expression of CCR5 and concomitantly expression of CCR5+CD69+CXCR6 suggesting a compensation of the remaining population of NKT cells for rapid effector action

    Hospital variation in transfusion and infection after cardiac surgery: a cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Transfusion practices in hospitalised patients are being re-evaluated, in part due to studies indicating adverse effects in patients receiving large quantities of stored blood. Concomitant with this re-examination have been reports showing variability in the use of specific blood components. This investigation was designed to assess hospital variation in blood use and outcomes in cardiac surgery patients.</p> <p>Methods</p> <p>We evaluated outcomes in 24,789 Medicare beneficiaries in the state of Michigan, USA who received coronary artery bypass graft surgery from 2003 to 2006. Using a cohort design, patients were followed from hospital admission to assess transfusions, in-hospital infection and mortality, as well as hospital readmission and mortality 30 days after discharge. Multilevel mixed-effects logistic regression was used to calculate the intrahospital correlation coefficient (for 40 hospitals) and compare outcomes by transfusion status.</p> <p>Results</p> <p>Overall, 30% (95 CI, 20% to 42%) of the variance in transfusion practices was attributable to hospital site. Allogeneic blood use by hospital ranged from 72.5% to 100% in women and 49.7% to 100% in men. Allogeneic, but not autologous, blood transfusion increased the odds of in-hospital infection 2.0-fold (95% CI 1.6 to 2.5), in-hospital mortality 4.7-fold (95% CI 2.4 to 9.2), 30-day readmission 1.4-fold (95% CI 1.2 to 1.6), and 30-day mortality 2.9-fold (95% CI 1.4 to 6.0) in elective surgeries. Allogeneic transfusion was associated with infections of the genitourinary system, respiratory tract, bloodstream, digestive tract and skin, as well as infection with <it>Clostridium difficile</it>. For each 1% increase in hospital transfusion rates, there was a 0.13% increase in predicted infection rates.</p> <p>Conclusion</p> <p>Allogeneic blood transfusion was associated with an increased risk of infection at multiple sites, suggesting a system-wide immune response. Hospital variation in transfusion practices after coronary artery bypass grafting was considerable, indicating that quality efforts may be able to influence practice and improve outcomes.</p

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≥20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≤pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≤{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
    • …
    corecore