686 research outputs found

    Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

    Get PDF
    Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients

    Multiscaling analysis of high resolution space-time lidar-rainfall

    Get PDF
    In this study, we report results from scaling analysis of 2.5 m spatial and 1 s temporal resolution lidar-rainfall data. The high resolution spatial and temporal data from the same observing system allows us to investigate the variability of rainfall at very small scales ranging from few meters to ~1 km in space and few seconds to ~30 min in time. The results suggest multiscaling behaviour in the lidar-rainfall with the scaling regime extending down to the resolution of the data. The results also indicate the existence of a space-time transformation of the form <i>t</i>~<i>L<sup>z</sup></i> at very small scales, where <i>t</i> is the time lag, <i>L</i> is the spatial averaging scale and <i>z</i> is the dynamic scaling exponent

    Localizing Defects in Multithreaded Programs by Mining Dynamic Call Graphs

    Get PDF
    Writing multithreaded software for multicore computers confronts many developers with the difficulty of finding parallel programming errors. In the past, most parallel debugging techniques have concentrated on finding race conditions due to wrong usage of synchronization constructs. A widely unexplored issue, however, is that a wrong usage of non-parallel programming constructs may also cause wrong parallel application behavior. This paper presents a novel defect-localization technique for multithreaded shared-memory programs that is based on analyzing execution anomalies. Compared to race detectors that report just on wrong synchronization, this method can detect a wider range of defects affecting parallel execution. It works on a condensed representation of the call graphs of multithreaded applications and employs data-mining techniques to locate a method containing a defect. Our results from controlled application experiments show that we found race conditions, but also other programming errors leading to incorrect parallel program behavior. On average, our approach reduced in our benchmark the amount of code to be inspected to just 7.1% of all methods

    Multisystem proteinopathy due to a homozygous p.Arg159His VCP mutation : a tale of the unexpected

    Get PDF
    ObjectiveTo assess the clinical, radiologic, myopathologic, and proteomic findings in a patient manifesting a multisystem proteinopathy due to a homozygous valosin-containing protein gene (VCP) mutation previously reported to be pathogenic in the heterozygous state.MethodsWe studied a 36-year-old male index patient and his father, both presenting with progressive limb-girdle weakness. Muscle involvement was assessed by MRI and muscle biopsies. We performed whole-exome sequencing and Sanger sequencing for segregation analysis of the identified p.Arg159His VCP mutation. To dissect biological disease signatures, we applied state-of-the-art quantitative proteomics on muscle tissue of the index case, his father, 3 additional patients with VCP-related myopathy, and 3 control individuals.ResultsThe index patient, homozygous for the known p.Arg159His mutation in VCP, manifested a typical VCP-related myopathy phenotype, although with a markedly high creatine kinase value and a relatively early disease onset, and Paget disease of bone. The father exhibited a myopathy phenotype and discrete parkinsonism, and multiple deceased family members on the maternal side of the pedigree displayed a dementia, parkinsonism, or myopathy phenotype. Bioinformatic analysis of quantitative proteomic data revealed the degenerative nature of the disease, with evidence suggesting selective failure of muscle regeneration and stress granule dyshomeostasis.ConclusionWe report a patient showing a multisystem proteinopathy due to a homozygous VCP mutation. The patient manifests a severe phenotype, yet fundamental disease characteristics are preserved. Proteomic findings provide further insights into VCP-related pathomechanisms

    Size-resolved aerosol emission factors and new particle formation/growth activity occurring in Mexico City during the MILAGRO 2006 Campaign

    Get PDF
    Measurements of the aerosol size distribution from 11 nm to 2.5 microns were made in Mexico City in March 2006, during the MILAGRO (Megacity Initiative: Local and Global Research Observations) field campaign. Observations at the urban supersite, referred to as T0, could often be characterized by morning conditions with high particle mass concentrations, low mixing heights, and highly correlated particle number and CO<sub>2</sub> concentrations, indicative that particle number is controlled by primary emissions. Average size-resolved and total number- and volume-based emission factors for combustion sources impacting T0 have been determined using a comparison of peak sizes in particle number and CO<sub>2</sub> concentration. Peaks are determined by subtracting the measured concentration from a calculated baseline concentration time series. The number emission and volume emission factors for particles from 11 nm to 494 nm are 1.56 × 10<sup>15</sup> particles, and 9.48 × 10<sup>11</sup> cubic microns per kg of carbon, respectively. The uncertainty of the number emission factor is approximately plus or minus 50 %. The mode of the number emission factor was between 25 and 32 nm, while the mode of the volume factor was between 0.25 and 0.32 microns. These emission factors are reported as log normal model parameters and are compared with multiple emission factors from the literature. In Mexico City in the afternoon, the CO<sub>2</sub> concentration drops during ventilation of the polluted layer, and the coupling between CO<sub>2</sub> and particle number breaks down, especially during new particle formation events when particle number is no longer controlled by primary emissions. Using measurements of particle number and CO<sub>2</sub> taken aboard the NASA DC-8, the determined primary emission factor was applied to the Mexico City Metropolitan Area (MCMA) plume to quantify the degree of secondary particle formation in the plume; the primary emission factor accounts for less than 50 % of the total particle number and the surplus particle count is not correlated with photochemical age. Primary particle volume and number in the size range 0.1–2 μm are similarly too low to explain the observed volume distribution. Contrary to the case for number, the apparent secondary volume increases with photochemical age. The size distribution of the apparent increase, with a mode at ~250 nm, is reported

    Convective scaling of the average dissipation rate of temperature variance in the atmospheric surface layer

    Get PDF
    The flux of sensible heat from the land surface is related to the average rate of dissipation of temperature fluctuations in the atmospheric surface layer through the temperature variance budget equation. In many cases it is desirable to estimate the heat flux from measurement or inference of the dissipation rate. Here we study how the dissipation rate scales with atmospheric stability, using three inertial range methods to calculate the dissipation rate: power spectra, second order structure functions, and third order structure functions. Experimental data are analyzed from a pair of field experiments, during which turbulent fluctuations of velocity and temperature were measured over a broad range of neutral and unstable atmospheric flows. It is shown that the temperature dissipation rate scales with a single convective power law continuously from near-neutral to strongly unstable stratification. The dissipation scaling is found to nearly match production in the near-neutral region, but to be consistently lower than production in the more convective regimes. The convective scaling is shown to offer a simplified means of computing sensible heat flux from the dissipation rate of temperature variance
    • …
    corecore