171 research outputs found

    Bioactive calcium phosphate coatings applied to flexible poly(carbonate urethane) foils

    Get PDF
    Long-term fixation of orthopaedic implants can be enhanced by tissue ingrowth techniques. As such, the deposition of a bioactive bone-like coating could be considered a promising method to facilitate the integration of implants onto bone tissue. In this study, we identified the optimized osteo-conductive Calcium Phosphate (CaP) coating parameters for deposition on PolyCarbonate-Urethane (PCU) foils. The oxygen plasma surface-activated PCU specimens were suspended in simulated body fluid (SBF) and supersaturated SBFs for 4 h, 8 h, 24 h, or 6 days at a temperature of 20 °C, 37 °C, or 50 °C. This resulted in semi-crystalline CaP coatings on a thin flexible foil via a one-step low-temperature aqueous technique. The deposited CaP coatings demonstrated high stability and remained intact upon bending deformation. According to the in vitro cell assessments, the conducted CaP coatings did not influence cell viability nor cell proliferation compared to the bare PCU substrate. In addition, the deposited CaP coatings enhanced the cell-mediated calcium deposition. All in all, this paper demonstrates a promising method to apply stable bioactive coatings to flexible PCU foils, which can be a promising strategy for the enhanced integration of PCU implants onto bone.</p

    Design and Evaluation of a Magnetic Rotablation Catheter for Arterial Stenosis

    Get PDF
    Arterial stenosis is a high-risk disease accompanied by large amounts of calcified deposits and plaques that develop inside the vasculature. These deposits should be reduced to improve blood flow. However, current methods used to reduce stenosis require externally-controlled actuation systems resulting in limited workspace or patient risks. This results in an unexplored preference regarding the revascularization strategy for symptomatic artery stenosis. In this paper, we propose a novel internally-actuated solution: a magnetic spring-loaded rotablation catheter. The catheter is developed to achieve stenosis-debulking capabilities by actuating drill bits using two internal electromagnetic coils and a magnetic reciprocating spring-loaded shaft. The state-space model of the catheter is validated by comparing the simulation results of the magnetic fields of the internal coils with the experimental results of a fabricated prototype. Contact forces of the catheter tip are measured experimentally, resulting in a maximum axial force of 2.63 N and a torque of 5.69 mN-m. Finally, we present interventions in which the catheter is inserted to a vascular target site and demonstrate plaque-specific treatment using different detachable actuator bits. Calcified deposits are debulked and visualized via ultrasound imaging. The catheter can reduce a stenosis cross-sectional area by up to 35%, indicating the potential for the treatment of calcified lesions, which could prevent restenosis

    A phase 1b study evaluating the effect of elacestrant treatment on estrogen receptor availability and estradiol binding to the estrogen receptor in metastatic breast cancer lesions using 18F-FES PET/CT imaging

    Get PDF
    Background: Elacestrant is an oral selective estrogen receptor (ER) degrader. This phase 1b open-label, nonrandomized study (RAD1901-106) was initiated to determine the effect of elacestrant on the availability of ER in lesions from postmenopausal women with ER+ advanced breast cancer (ABC) using 16α18F-fluoro-17β-estradiol positron emission tomography with low-dose computed tomography (FES-PET/CT). Methods: Eligible patients were postmenopausal women with ER+, HER2− ABC; tumor progression after ≥ 6 months of 1–3 lines of endocrine treatment for ABC; and measurable or evaluable disease. Two 8-patient cohorts were enrolled: one treated with 400 mg elacestrant once daily (QD) and one treated with 200 mg elacestrant QD with dose escalation to 400 mg QD after 14 days. Elacestrant was dosed continuously until progressive disease, toxicity, or withdrawal. FES-PET/CT was performed pre-dose at baseline and 4 h post-dose on day 14. The primary endpoint was the percentage difference in FES uptake in tumor lesions (maximum 20) after 14 days of treatment compared to baseline. Overall response was investigator-assessed by Response Evaluation Criteria in Solid T

    Nuclear Skins and Halos in the Mean-Field Theory

    Full text link
    Nuclei with large neutron-to-proton ratios have neutron skins, which manifest themselves in an excess of neutrons at distances greater than the radius of the proton distribution. In addition, some drip-line nuclei develop very extended halo structures. The neutron halo is a threshold effect; it appears when the valence neutrons occupy weakly bound orbits. In this study, nuclear skins and halos are analyzed within the self-consistent Skyrme-Hartree-Fock-Bogoliubov and relativistic Hartree-Bogoliubov theories for spherical shapes. It is demonstrated that skins, halos, and surface thickness can be analyzed in a model-independent way in terms of nucleonic density form factors. Such an analysis allows for defining a quantitative measure of the halo size. The systematic behavior of skins, halos, and surface thickness in even-even nuclei is discussed.Comment: 22 RevTeX pages, 22 EPS figures included, submitted to Physical Review

    Graph Neural Networks for low-energy event classification & reconstruction in IceCube

    Get PDF
    IceCube, a cubic-kilometer array of optical sensors built to detect atmospheric and astrophysical neutrinos between 1 GeV and 1 PeV, is deployed 1.45 km to 2.45 km below the surface of the ice sheet at the South Pole. The classification and reconstruction of events from the in-ice detectors play a central role in the analysis of data from IceCube. Reconstructing and classifying events is a challenge due to the irregular detector geometry, inhomogeneous scattering and absorption of light in the ice and, below 100 GeV, the relatively low number of signal photons produced per event. To address this challenge, it is possible to represent IceCube events as point cloud graphs and use a Graph Neural Network (GNN) as the classification and reconstruction method. The GNN is capable of distinguishing neutrino events from cosmic-ray backgrounds, classifying different neutrino event types, and reconstructing the deposited energy, direction and interaction vertex. Based on simulation, we provide a comparison in the 1 GeV–100 GeV energy range to the current state-of-the-art maximum likelihood techniques used in current IceCube analyses, including the effects of known systematic uncertainties. For neutrino event classification, the GNN increases the signal efficiency by 18% at a fixed background rate, compared to current IceCube methods. Alternatively, the GNN offers a reduction of the background (i.e. false positive) rate by over a factor 8 (to below half a percent) at a fixed signal efficiency. For the reconstruction of energy, direction, and interaction vertex, the resolution improves by an average of 13%–20% compared to current maximum likelihood techniques in the energy range of 1 GeV–30 GeV. The GNN, when run on a GPU, is capable of processing IceCube events at a rate nearly double of the median IceCube trigger rate of 2.7 kHz, which opens the possibility of using low energy neutrinos in online searches for transient events.Peer Reviewe

    Dutch Oncology COVID-19 consortium:Outcome of COVID-19 in patients with cancer in a nationwide cohort study

    Get PDF
    Aim of the study: Patients with cancer might have an increased risk for severe outcome of coronavirus disease 2019 (COVID-19). To identify risk factors associated with a worse outcome of COVID-19, a nationwide registry was developed for patients with cancer and COVID-19. Methods: This observational cohort study has been designed as a quality of care registry and is executed by the Dutch Oncology COVID-19 Consortium (DOCC), a nationwide collaboration of oncology physicians in the Netherlands. A questionnaire has been developed to collect pseudonymised patient data on patients' characteristics, cancer diagnosis and treatment. All patients with COVID-19 and a cancer diagnosis or treatment in the past 5 years are eligible. Results: Between March 27th and May 4th, 442 patients were registered. For this first analysis, 351 patients were included of whom 114 patients died. In multivariable analyses, age ≥65 years (p < 0.001), male gender (p = 0.035), prior or other malignancy (p = 0.045) and active diagnosis of haematological malignancy (p = 0.046) or lung cancer (p = 0.003) were independent risk factors for a fatal outcome of COVID-19. In a subgroup analysis of patients with active malignancy, the risk for a fatal outcome was mainly determined by tumour type (haematological malignancy or lung cancer) and age (≥65 years). Conclusion: The findings in this registry indicate that patients with a haematological malignancy or lung cancer have an increased risk of a worse outcome of COVID-19. During the ongoing COVID-19 pandemic, these vulnerable patients should avoid exposure to severe acute respiratory syndrome coronavirus 2, whereas treatment adjustments and prioritising vaccination, when available, should also be considered

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
    corecore