897 research outputs found

    Correlated Lateral Diffusion of Lipids

    Get PDF

    Real-time non-perturbative dynamics of jet production: quantum entanglement and vacuum modification

    Full text link
    The production of jets should allow testing the real-time response of the QCD vacuum disturbed by the propagation of high-momentum color charges. Addressing this problem theoretically requires a real-time, non-perturbative method. It is well known that the Schwinger model [QED in (1+1)(1+1) dimensions] shares many common properties with QCD, including confinement, chiral symmetry breaking, and the existence of vacuum fermion condensate. As a step in developing such an approach, we report here on fully quantum simulations of a massive Schwinger model coupled to external sources representing quark and antiquark jets as produced in e+e−e^+e^- annihilation. We study, for the first time, the modification of the vacuum chiral condensate by the propagating jets and the quantum entanglement between the fragmenting jets. Our results indicate strong entanglement between the fragmentation products of the two jets at rapidity separations Δη≤2\Delta \eta \leq 2, which can potentially exist also in QCD and can be studied in experiments.Comment: 5 pages + supplementary materials, 10 figures; final versio

    FRAP to Characterize Molecular Diffusion and Interaction in Various Membrane Environments

    Get PDF
    Fluorescence recovery after photobleaching (FRAP) is a standard method used to study the dynamics of lipids and proteins in artificial and cellular membrane systems. The advent of confocal microscopy two decades ago has made quantitative FRAP easily available to most laboratories. Usually, a single bleaching pattern/area is used and the corresponding recovery time is assumed to directly provide a diffusion coefficient, although this is only true in the case of unrestricted Brownian motion. Here, we propose some general guidelines to perform FRAP experiments under a confocal microscope with different bleaching patterns and area, allowing the experimentalist to establish whether the molecules undergo Brownian motion (free diffusion) or whether they have restricted or directed movements. Using in silico simulations of FRAP measurements, we further indicate the data acquisition criteria that have to be verified in order to obtain accurate values for the diffusion coefficient and to be able to distinguish between different diffusive species. Using this approach, we compare the behavior of lipids in three different membrane platforms (supported lipid bilayers, giant liposomes and sponge phases), and we demonstrate that FRAP measurements are consistent with results obtained using other techniques such as Fluorescence Correlation Spectroscopy (FCS) or Single Particle Tracking (SPT). Finally, we apply this method to show that the presence of the synaptic protein Munc18-1 inhibits the interaction between the synaptic vesicle SNARE protein, VAMP2, and its partner from the plasma membrane, Syn1A

    Surfactant Bilayers Maintain Transmembrane Protein Activity

    Get PDF
    AbstractIn vitro studies of membrane proteins are of interest only if their structure and function are significantly preserved. One approach is to insert them into the lipid bilayers of highly viscous cubic phases rendering the insertion and manipulation of proteins difficult. Less viscous lipid sponge phases are sometimes used, but their relatively narrow domain of existence can be easily disrupted by protein insertion. We present here a sponge phase consisting of nonionic surfactant bilayers. Its extended domain of existence and its low viscosity allow easy insertion and manipulation of membrane proteins. We show for the first time, to our knowledge, that transmembrane proteins, such as bacteriorhodopsin, sarcoplasmic reticulum Ca2+ATPase (SERCA1a), and its associated enzymes, are fully active in a surfactant phase

    Vulnerability of CMOS image sensors in megajoule class laser harsh environment

    Get PDF
    CMOS image sensors (CIS) are promising candidates as part of optical imagers for the plasma diagnostics devoted to the study of fusion by inertial confinement. However, the harsh radiative environment of Megajoule Class Lasers threatens the performances of these optical sensors. In this paper, the vulnerability of CIS to the transient and mixed pulsed radiation environment associated with such facilities is investigated during an experiment at the OMEGA facility at the Laboratory for Laser Energetics (LLE), Rochester, NY, USA. The transient and permanent effects of the 14 MeV neutron pulse on CIS are presented. The behavior of the tested CIS shows that active pixel sensors (APS) exhibit a better hardness to this harsh environment than a CCD. A first order extrapolation of the reported results to the higher level of radiation expected for Megajoule Class Laser facilities (Laser Megajoule in France or National Ignition Facility in the USA) shows that temporarily saturated pixels due to transient neutron-induced single event effects will be the major issue for the development of radiation-tolerant plasma diagnostic instruments whereas the permanent degradation of the CIS related to displacement damage or total ionizing dose effects could be reduced by applying well known mitigation techniques

    Hardening approach to use CMOS image sensors for fusion by inertial confinement diagnostics

    Get PDF
    A hardening method is proposed to enable the use of CMOS image sensors for Fusion by Inertial Confinement Diagnostics. The mitigation technique improves their radiation tolerance using a reset mode implemented in the device. The results obtained evidence a reduction of more than 70% in the number of transient white pixels induced in the pixel array by the mixed neutron and γ-ray pulsed radiation environment
    • …
    corecore