555 research outputs found
Radar High Resolution Range & Micro-Doppler Analysis of Human Motions
In radar imaging it is well known that relative motion or deformation of parts of illuminated objects induce additional features in the Doppler frequency spectra. These features are called micro-Doppler effect and appear as sidebands around the central Doppler frequency. They can provide valuable information about the structure of the moving parts and may be used for identification purposes [1]. Previous papers have mostly focused on ID micro-Doppler analysis [2-4]. In this paper, we propose to emphasize the analysis of such "non stationary targets" using a 2D imaging space, using both the micro-Doppler and a high range resolution analysis. As in 2D-ISAR imaging, range separation enables us to better discriminate the various effects caused by the time varying reflectors. We will focus our study on human motion. We will see how micro-Doppler signature can be used to extract information on pedestrians gait. We will show examples on simulated and experimental data
Whole genome sequences of two Salmonella Dublin strains harbour viaA, viaB and ompB loci of the Vi antigen
Here we report the genome sequence of two Salmonella enterica serovar Dublin, 03EB8736SAL and 03EB8994SAL, isolated from raw milk cheese and filter of milk respectively. Analysis of draft genomes of the two isolates reveals the presence of viaA, viaB and ompB loci of the Vi capsular polysaccharide antigen (Vi antigen)
Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
BACKGROUND: Integrated PET/MRI with hyperpolarized (13)C magnetic resonance spectroscopic imaging ((13)C-MRSI) offers simultaneous, dual-modality metabolic imaging. A prerequisite for the use of simultaneous imaging is the absence of interference between the two modalities. This has been documented for a clinical whole-body system using simultaneous (1)H-MRI and PET but never for (13)C-MRSI and PET. Here, the feasibility of simultaneous PET and (13)C-MRSI as well as hyperpolarized (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is evaluated using phantom experiments. METHODS: Combined PET and (13)C-MRSI phantoms including a NEMA [(18)F]-FDG phantom, (13)C-acetate and (13)C-urea sources, and hyperpolarized (13)C-pyruvate were imaged repeatedly with PET and/or (13)C-MRSI. Measurements evaluated for interference effects included PET activity values in the largest sphere and a background region; total number of PET trues; and (13)C-MRSI signal-to-noise ratio (SNR) for urea and acetate phantoms. Differences between measurement conditions were evaluated using t tests. RESULTS: PET and (13)C-MRSI data acquisition could be performed simultaneously without any discernible artifacts. The average difference in PET activity between acquisitions with and without simultaneous (13)C-MRSI was 0.83 (largest sphere) and −0.76 % (background). The average difference in net trues was −0.01 %. The average difference in (13)C-MRSI SNR between acquisitions with and without simultaneous PET ranged from −2.28 to 1.21 % for all phantoms and measurement conditions. No differences were significant. The system was capable of (13)C-MRSI of hyperpolarized (13)C-pyruvate. CONCLUSIONS: Simultaneous PET and (13)C-MRSI in an integrated whole-body PET/MRI hybrid scanner is feasible. Phantom experiments showed that possible interference effects introduced by acquiring data from the two modalities simultaneously are small and non-significant. Further experiments can now investigate the benefits of simultaneous PET and hyperpolarized (13)C-MRI in vivo studies
Recommended from our members
New experimental limits on the Pauli forbidden transitions in C nuclei obtained with 485 days Borexino data
The Pauli exclusion principle (PEP) has been tested for nucleons () in
with the Borexino detector.The approach consists of a search for
, , and emitted in a non-Paulian transition of
1- shell nucleons to the filled 1 shell in nuclei. Due to the
extremely low background and the large mass (278 t) of the Borexino detector,
the following most stringent up-to-date experimental bounds on PEP violating
transitions of nucleons have been established:
y, y,
y,
y and y, all at 90% C.L. The corresponding upper
limits on the relative strengths for the searched non-Paulian electromagnetic,
strong and weak transitions have been estimated: , and .Comment: 9 pages, 6 figure
Recent Borexino results and prospects for the near future
The Borexino experiment, located in the Gran Sasso National Laboratory, is an
organic liquid scintillator detector conceived for the real time spectroscopy
of low energy solar neutrinos. The data taking campaign phase I (2007 - 2010)
has allowed the first independent measurements of 7Be, 8B and pep fluxes as
well as the first measurement of anti-neutrinos from the earth. After a
purification of the scintillator, Borexino is now in phase II since 2011. We
review here the recent results achieved during 2013, concerning the seasonal
modulation in the 7Be signal, the study of cosmogenic backgrounds and the
updated measurement of geo-neutrinos. We also review the upcoming measurements
from phase II data (pp, pep, CNO) and the project SOX devoted to the study of
sterile neutrinos via the use of a 51Cr neutrino source and a 144Ce-144Pr
antineutrino source placed in close proximity of the active material.Comment: 8 pages, 11 figures. To be published as proceedings of Rencontres de
Moriond EW 201
Recommended from our members
Search for Solar Axions Produced in Reaction with Borexino Detector
A search for 5.5-MeV solar axions produced in the reaction was performed using the Borexino detector. The Compton
conversion of axions to photons, ; the
axio-electric effect, ; the decay of axions into
two photons, ; and inverse Primakoff conversion on
nuclei, , are considered. Model independent
limits on axion-electron (), axion-photon (), and
isovector axion-nucleon () couplings are obtained: and at 1 MeV (90% c.l.). These limits are
2-4 orders of magnitude stronger than those obtained in previous
laboratory-based experiments using nuclear reactors and accelerators.Comment: 11 pages, 7 figures, submitted to Phys.Rev.
Search for electron antineutrino interactions with the Borexino Counting Test Facility at Gran Sasso
Electron antineutrino interactions above the inverse beta decay energy of
protons (E_\bar{\nu}_e>1.8) where looked for with the Borexino Counting Test
Facility (CTF). One candidate event survived after rejection of background,
which included muon-induced neutrons and random coincidences. An upper limit on
the solar flux, assumed having the B solar neutrino energy
spectrum, of 1.1 cm~s (90% C.L.) was set with a 7.8
ton year exposure. This upper limit corresponds to a solar neutrino
transition probability, , of 0.02 (90% C.L.).
Predictions for antineutrino detection with Borexino, including geoneutrinos,
are discussed on the basis of background measurements performed with the CTF.Comment: 10 pages, 9 figures, 5 table
Pulse-Shape discrimination with the Counting Test Facility
Pulse shape discrimination (PSD) is one of the most distinctive features of
liquid scintillators. Since the introduction of the scintillation techniques in
the field of particle detection, many studies have been carried out to
characterize intrinsic properties of the most common liquid scintillator
mixtures in this respect. Several application methods and algorithms able to
achieve optimum discrimination performances have been developed. However, the
vast majority of these studies have been performed on samples of small
dimensions. The Counting Test Facility, prototype of the solar neutrino
experiment Borexino, as a 4 ton spherical scintillation detector immersed in
1000 tons of shielding water, represents a unique opportunity to extend the
small-sample PSD studies to a large-volume setup. Specifically, in this work we
consider two different liquid scintillation mixtures employed in CTF,
illustrating for both the PSD characterization results obtained either with the
processing of the scintillation waveform through the optimum Gatti's method, or
via a more conventional approach based on the charge content of the
scintillation tail. The outcomes of this study, while interesting per se, are
also of paramount importance in view of the expected Borexino detector
performances, where PSD will be an essential tool in the framework of the
background rejection strategy needed to achieve the required sensitivity to the
solar neutrino signals.Comment: 39 pages, 17 figures, submitted to Nucl. Instr. Meth.
Recommended from our members
Measurement of geo-neutrinos from 1353 days of Borexino
We present a measurement of the geo--neutrino signal obtained from 1353 days
of data with the Borexino detector at Laboratori Nazionali del Gran Sasso in
Italy. With a fiducial exposure of (3.69 0.16) proton
year after all selection cuts and background subtraction, we detected
(14.3 4.4) geo-neutrino events assuming a fixed chondritic mass Th/U
ratio of 3.9. This corresponds to a geo-neutrino signal = (38.8
12.0) TNU with just a 6 probability for a null geo-neutrino
measurement. With U and Th left as free parameters in the fit, the relative
signals are = (10.6 12.7) TNU and =
(26.5 19.5) TNU. Borexino data alone are compatible with a mantle
geo--neutrino signal of (15.4 12.3) TNU, while a combined analysis with
the KamLAND data allows to extract a mantle signal of (14.1 8.1) TNU. Our
measurement of a reactor anti--neutrino signal =
84.5 TNU is in agreement with expectations in the presence of
neutrino oscillations.Comment: 9 pages, 6 figure
- …