1,075 research outputs found

    Friction as Contrast Mechanism in Heterodyne Force Microscopy

    Get PDF
    The nondestructive imaging of subsurface structures on the nanometer scale has been a long-standing desire in both science and industry. A few impressive images were published so far that demonstrate the general feasibility by combining ultrasound with an Atomic Force Microscope. From different excitation schemes, Heterodyne Force Microscopy seems to be the most promising candidate delivering the highest contrast and resolution. However, the physical contrast mechanism is unknown, thereby preventing any quantitative analysis of samples. Here we show that friction at material boundaries within the sample is responsible for the contrast formation. This result is obtained by performing a full quantitative analysis, in which we compare our experimentally observed contrasts with simulations and calculations. Surprisingly, we can rule out all other generally believed responsible mechanisms, like Rayleigh scattering, sample (visco)elasticity, damping of the ultrasonic tip motion, and ultrasound attenuation. Our analytical description paves the way for quantitative SubSurface-AFM imaging.Comment: 7 pages main paper + 11 pages supplementary material

    Lutz-Kelker bias in pulsar parallax measurements

    Get PDF
    Lutz & Kelker showed that parallax measurements are systematically overestimated because they do not properly account for the larger volume of space that is sampled at smaller parallax values. We apply their analysis to neutron stars, incorporating the bias introduced by the intrinsic radio luminosity function and a realistic Galactic population model for neutron stars. We estimate the bias for all published neutron star parallax measurements and find that measurements with less than ~95% certainty, are likely to be significantly biased. Through inspection of historic parallax measurements, we confirm the described effects in optical and radio measurements, as well as in distance estimates based on interstellar dispersion measures. The potential impact on future tests of relativistic gravity through pulsar timing and on X-ray--based estimates of neutron star radii is briefly discussed.Comment: 9 pages, 3 tables, 1 figure. Accepted for publication in MNRA

    Interplay between nanometer-scale strain variations and externally applied strain in graphene

    Get PDF
    We present a molecular modeling study analyzing nanometer-scale strain variations in graphene as a function of externally applied tensile strain. We consider two different mechanisms that could underlie nanometer-scale strain variations: static perturbations from lattice imperfections of an underlying substrate and thermal fluctuations. For both cases we observe a decrease in the out-of-plane atomic displacements with increasing strain, which is accompanied by an increase in the in-plane displacements. Reflecting the non-linear elastic properties of graphene, both trends together yield a non-monotonic variation of the total displacements with increasing tensile strain. This variation allows to test the role of nanometer-scale strain variations in limiting the carrier mobility of high-quality graphene samples

    Low-Frequency Spectral Turn-Overs in Millisecond Pulsars Studied from Imaging Observations

    Full text link
    Measurements of pulsar flux densities are of great importance for understanding the pulsar emission mechanism and for predictions of pulsar survey yields and the pulsar population at large. Typically these flux densities are determined from phase-averaged "pulse profiles", but this method has limited applicability at low frequencies because the observed pulses can easily be spread out by interstellar effects like scattering or dispersion, leading to a non-pulsed continuum component that is necessarily ignored in this type of analysis. In particular for the class of the millisecond pulsars (MSPs) at frequencies below 200MHz, such interstellar effects can seriously compromise de- tectability and measured flux densities. In this paper we investigate MSP spectra based on a complementary approach, namely through investigation of archival con- tinuum imaging data. Even though these images lose sensitivity to pulsars since the on-pulse emission is averaged with off-pulse noise, they are insensitive to effects from scattering and provide a reliable way to determine the flux density and spectral indices of MSPs based on both pulsed and unpulsed components. Using the 74MHz VLSSr as well as the 325MHz WENSS and 1.4GHz NVSS catalogues, we investigate the imaging flux densities of MSPs and evaluate the likelihood of spectral turn-overs in this population. We determine three new MSP spectral indices and identify six new MSPs with likely spectral turn-overs.Comment: 10 pages, 4 figures, 3 tables, accepted for publication in MNRA

    Limits on the Mass, Velocity and Orbit of PSR J1933−-6211

    Full text link
    We present a high-precision timing analysis of PSR J1933−-6211, a millisecond pulsar (MSP) with a 3.5-ms spin period and a white dwarf (WD) companion, using data from the Parkes radio telescope. Since we have accurately measured the polarization properties of this pulsar we have applied the matrix template matching approach in which the times of arrival are measured using full polarimetric information. We achieved a weighted root-mean-square timing residuals (rms) of the timing residuals of 1.23 μs\rm \mu s, 15.5%\% improvement compared to the total intensity timing analysis. After studying the scintillation properties of this pulsar we put constraints on the inclination angle of the system. Based on these measurements and on χ2\chi^2 mapping we put a 2-σ\sigma upper limit on the companion mass (0.44 M⊙_\odot). Since this mass limit cannot reveal the nature of the companion we further investigate the possibility of the companion to be a He WD. Applying the orbital period-mass relation for such WDs, we conclude that the mass of a He WD companion would be about 0.26±\pm0.01 M⊙_\odot which, combined with the measured mass function and orbital inclination limits, would lead to a light pulsar mass ⩽\leqslant 1.0 M⊙_\odot. This result seems unlikely based on current neutron star formation models and we therefore conclude that PSR J1933−-6211 most likely has a CO WD companion, which allows for a solution with a more massive pulsar

    Fabrication of comb-drive actuators for straining nanostructured suspended graphene

    Full text link
    We report on the fabrication and characterization of an optimized comb-drive actuator design for strain-dependent transport measurements on suspended graphene. We fabricate devices from highly p-doped silicon using deep reactive ion etching with a chromium mask. Crucially, we implement a gold layer to reduce the device resistance from ≈51.6\approx51.6 kΩ\mathrm{\Omega} to ≈236\approx236 Ω\mathrm{\Omega} at room temperature in order to allow for strain-dependent transport measurements. The graphene is integrated by mechanically transferring it directly onto the actuator using a polymethylmethacrylate membrane. Importantly, the integrated graphene can be nanostructured afterwards to optimize device functionality. The minimum feature size of the structured suspended graphene is 30 nm, which allows for interesting device concepts such as mechanically-tunable nanoconstrictions. Finally, we characterize the fabricated devices by measuring the Raman spectrum as well as the a mechanical resonance frequency of an integrated graphene sheet for different strain values.Comment: 10 pages, 9 figure

    Assessing the Role of Spin Noise in the Precision Timing of Millisecond Pulsars

    Full text link
    We investigate rotational spin noise (referred to as timing noise) in non-accreting pulsars: millisecond pulsars, canonical pulsars, and magnetars. Particular attention is placed on quantifying the strength and non-stationarity of timing noise in millisecond pulsars because the long-term stability of these objects is required to detect nanohertz gravitational radiation. We show that a single scaling law is sufficient to characterize timing noise in millisecond and canonical pulsars while the same scaling law underestimates the levels of timing noise in magnetars. The scaling law, along with a detailed study of the millisecond pulsar B1937+21, leads us to conclude that timing noise is latent in most millisecond pulsars and will be measurable in many objects when better arrival time estimates are obtained over long data spans. The sensitivity of a pulsar timing array to gravitational radiation is strongly affected by any timing noise. We conclude that detection of proposed gravitational wave backgrounds will require the analysis of more objects than previously suggested over data spans that depend on the spectra of both the gravitational wave background and of the timing noise. It is imperative to find additional millisecond pulsars in current and future surveys in order to reduce the effects of timing noise.Comment: 16 pages and 6 figures. ApJ, accepte

    Tunable mechanical coupling between driven microelectromechanical resonators

    Full text link
    We present a microelectromechanical system, in which a silicon beam is attached to a comb-drive actuator, that is used to tune the tension in the silicon beam, and thus its resonance frequency. By measuring the resonance frequencies of the system, we show that the comb-drive actuator and the silicon beam behave as two strongly coupled resonators. Interestingly, the effective coupling rate (~ 1.5 MHz) is tunable with the comb-drive actuator (+10%) as well as with a side-gate (-10%) placed close to the silicon beam. In contrast, the effective spring constant of the system is insensitive to either of them and changes only by ±\pm 0.5%. Finally, we show that the comb-drive actuator can be used to switch between different coupling rates with a frequency of at least 10 kHz.Comment: 5 pages, 4 figures, 1 tabl

    Postpartum Health Services Requested by Mothers with Newborns Receiving Intensive Care

    Get PDF
    Objectives Our pilot study aimed to build knowledge of the postpartum health needs of mothers with infants in a newborn intensive care unit (NICU). Methods Between May 2008 and December 2009, a Certified Nurse Midwife was available during workday hours to provide health care services to mothers visiting their infants in the NICU at a large tertiary care center. Results A total of 424 health service encounters were recorded. Maternal requests for services covered a wide variety of needs, with primary care being the most common. Key health concerns included blood pressure monitoring, colds, coughs, sore throats, insomnia and migraines. Mothers also expressed a need for mental health assessment and support, obstetric care, treatment for sexually transmitted infections, tobacco cessation, breastfeeding assistance, postpartum visits, and provision of contraception. Conclusions Our study suggests that mothers with babies in the NICU have a host of health needs. We also found that women were receptive to receiving health services in a critical care pediatric setting. Intensive care nurseries could feasibly partner with in-patient mother-baby units and/or on-site obstetric clinics to increase access to health care for the mothers of the high-risk newborns in their units. Modifications should be made within health care systems that serve high-risk infants to better address the many needs of the mother/baby dyad in the postpartum period
    • …
    corecore