4,780 research outputs found

    Wireless, in-vessel neutron monitor for initial core-loading of advanced breeder reactors

    Get PDF
    An experimental wireless, in-vessel neutron monitor was developed to measure the reactivity of an advanced breeder reactor as the core is loaded for the first time to preclude an accidental critically incident. The environment is liquid sodium at a temperature of approx. 220 C, with negligible gamma or neutron radiation. With ultrasonic transmission of neutron data, no fundamental limitation was observed after tests at 230 C for 2000 h. The neutron sensitivity was approx. 1 count/s-nv, and the potential data transmission rate was approx. 10,000 counts/s

    Estimating the duration of speciation from phylogenies

    Get PDF
    Speciation is not instantaneous but takes time. The protracted birth-death diversification model incorporates this fact and predicts the often observed slowdown of lineage accumulation toward the present. The mathematical complexity of the protracted speciation model has barred estimation of its parameters until recently a method to compute the likelihood of phylogenetic branching times under this model was outlined (Lambert et al. ). Here, we implement this method and study using simulated phylogenies of extant species how well we can estimate the model parameters (rate of initiation of speciation, rate of extinction of incipient and good species, and rate of completion of speciation) as well as the duration of speciation, which is a combination of the aforementioned parameters. We illustrate our approach by applying it to a primate phylogeny. The simulations show that phylogenies often do not contain enough information to provide unbiased estimates of the speciation-initiation rate and the extinction rate, but the duration of speciation can be estimated without much bias. The estimate of the duration of speciation for the primate clade is consistent with literature estimates. We conclude that phylogenies combined with the protracted speciation model provide a promising way to estimate the duration of speciation.</p

    Molecular and morphometric variation in European populations of the articulate brachiopod <i>Terebeatulina retusa</i>

    Get PDF
    Molecular and morphometric variation within and between population samples of the articulate brachiopod &lt;i&gt;Terebratulina&lt;/i&gt; spp., collected in 1985-1987 from a Norwegian fjord, sea lochs and costal sites in western Scotland, the southern English Channel (Brittany) and the western Mediterranean, were measured by the analysis of variation in the lengths of mitochondrial DNA (mtDNA) fragments produced by digestion with nine restriction endonucleases and by multivariate statistical analysis of six selected morphometric parameters. Nucleotide difference within each population sample was high. Nucleotide difference between population samples from the Scottish sites, both those that are tidally contiguous and those that appear to be geographically isolated, were not significantly different from zero. Nucleotide differences between the populations samples from Norway, Brittany, Scotland and the western Mediterranean were also very low. Morphometric analysis confirmed the absence of substantial differentiation

    Electric and Magnetic Excitation of Coherent Magnetic Plasmon Waves in a One-dimensional Meta-chain

    Full text link
    A one-dimensional diatomic meta-chain with equal-size holes and different-length slits is designed. Broadband coherent magnetic plasmon waves (MPW) are formed in such a system, excited by both the electric resonance in the slits and the magnetic resonance in the holes in a wide range of incidence angles (00-400) and broad frequency bands (200-230 THz). The dispersion properties of the MPW measured in our experiments agree with the theoretical calculation based on the Lagrange model. The coherent MPWs reported in this paper may have applications in subwavelength integrated nanocircuits

    The interview as narrative ethnography : seeking and shaping connections in qualitative research.

    Get PDF
    Acts of counter-subjectification in qualitative research are always present but are often submerged in accounts that seek to locate the power of subjectification entirely with the researcher. This is particularly so when talking to people about sensitive issues. Based on an interview-based study of infertility and reproductive disruption among British Pakistanis in Northeast England, we explore how we, as researchers, sought and were drawn into various kinds of connections with the study participants; connections that were actively and performatively constructed through time. The three of us that conducted interviews are all female academics with Ph.Ds in anthropology, but thereafter our backgrounds, life stories and experiences diverge in ways that intersected with those of our informants in complex and shifting ways. We describe how these processes shaped the production of narrative accounts and consider some of the associated analytical and ethical implications

    Microrheology with optical tweezers: data analysis

    Get PDF
    We present a data analysis procedure that provides the solution to a long-standing issue in microrheology studies, i.e. the evaluation of the fluids' linear viscoelastic properties from the analysis of a finite set of experimental data, describing (for instance) the time-dependent mean-square displacement of suspended probe particles experiencing Brownian fluctuations. We report, for the first time in the literature, the linear viscoelastic response of an optically trapped bead suspended in a Newtonian fluid, over the entire range of experimentally accessible frequencies. The general validity of the proposed method makes it transferable to the majority of microrheology and rheology techniques

    Unified analysis of terminal-time control in classical and quantum systems

    Full text link
    Many phenomena in physics, chemistry, and biology involve seeking an optimal control to maximize an objective for a classical or quantum system which is open and interacting with its environment. The complexity of finding an optimal control for maximizing an objective is strongly affected by the possible existence of sub-optimal maxima. Within a unified framework under specified conditions, control objectives for maximizing at a terminal time physical observables of open classical and quantum systems are shown to be inherently free of sub-optimal maxima. This attractive feature is of central importance for enabling the discovery of controls in a seamless fashion in a wide range of phenomena transcending the quantum and classical regimes.Comment: 10 page

    Electrical Control of Plasmon Resonance with Graphene

    Full text link
    Surface plasmon, with its unique capability to concentrate light into sub-wavelength volume, has enabled great advances in photon science, ranging from nano-antenna and single-molecule Raman scattering to plasmonic waveguide and metamaterials. In many applications it is desirable to control the surface plasmon resonance in situ with electric field. Graphene, with its unique tunable optical properties, provides an ideal material to integrate with nanometallic structures for realizing such control. Here we demonstrate effective modulation of the plasmon resonance in a model system composed of hybrid graphene-gold nanorod structure. Upon electrical gating the strong optical transitions in graphene can be switched on and off, which leads to significant modulation of both the resonance frequency and quality factor of plasmon resonance in gold nanorods. Hybrid graphene-nanometallic structures, as exemplified by this combination of graphene and gold nanorod, provide a general and powerful way for electrical control of plasmon resonances. It holds promise for novel active optical devices and plasmonic circuits at the deep subwavelength scale

    Accuracy and utility of three-dimensional contrast-enhanced magnetic resonance angiography in planning carotid stenting

    Get PDF
    BackgroundContrast-enhanced magnetic resonance angiography (CE-MRA) is a proven diagnostic tool for the evaluation of carotid stenosis; however, its utility in planning carotid artery stenting (CAS) has not been addressed. This study assessed the accuracy of three-dimensional CE-MRA as a noninvasive screening tool, compared with digital subtraction angiography (DSA), for evaluating carotid and arch morphology before CAS.MethodsIn a series of 96 CAS procedures during a 2-year period, CE-MRAs and DSAs with complete visualization from the aortic arch to the intracranial circulation were obtained before CAS in 60 patients. Four additional patients, initially considered potential candidates for CAS, were also evaluated with CE-MRA and DSA. The two-by-two table method, receiver operating characteristic curve, and Bland-Altman analyses were used to characterize the ability of CE-MRA to discriminate carotid and arch anatomy, suitability for CAS, and degree of carotid stenosis.ResultsThe sensitivity and specificity of CE-MRA were, respectively, 100% and 100% to determine CAS suitability, 87% and 100% to define aortic arch type, 93% and 100% to determine severe carotid tortuosity, and 75% and 98% to detect ulcerated plaques. CE-MRA had 87% sensitivity and 100% specificity for the detection of carotid stenosis ≥80%. The accuracy of CE MRA to determine optimal imaging angles and stent and embolic protection device sizes was >90%. The operative technique for CAS was altered because of the findings of preoperative CE-MRA in 22 procedures (38%). The most frequent change in the operative plan was the use of the telescoping technique in 11 cases (18%). CAS was aborted in four patients (5%) due to unfavorable anatomy identified on CE-MRA, including prohibitive internal carotid artery tortuosity (n = 1), long string sign of the internal carotid artery (n = 2), and concomitant intracranial disease (n = 1). Among patients considered suitable for CAS by CE-MRA, technical success was 100%, and the 30-day stroke/death rate was 1.6%.ConclusionsContrast-enhanced magnetic resonance angiography of the arch and carotid arteries is accurate in determining suitability for CAS and may alter the operative technique. Certain anatomic contraindications for CAS may be detected without DSA. Although CE-MRA is less accurate to estimate the degree of stenosis, it can accurately predict imaging angles, and stent and embolic protection device size, which may facilitate safe and expeditious CAS
    corecore