38 research outputs found
On the Beaming of Gluonic Fields at Strong Coupling
We examine the conditions for beaming of the gluonic field sourced by a heavy
quark in strongly-coupled conformal field theories, using the AdS/CFT
correspondence. Previous works have found that, contrary to naive expectations,
it is possible to set up collimated beams of gluonic radiation despite the
strong coupling. We show that, on the gravity side of the correspondence, this
follows directly (for arbitrary quark motion, and independently of any
approximations) from the fact that the string dual to the quark remains
unexpectedly close to the AdS boundary whenever the quark moves
ultra-relativistically. We also work out the validity conditions for a related
approximation scheme that proposed to explain the beaming effect though the
formation of shock waves in the bulk fields emitted by the string. We find that
these conditions are fulfilled in the case of ultra-relativistic uniform
circular motion that motivated the proposal, but unfortunately do not hold for
much more general quark trajectories.Comment: 1+33 pages, 2 figure
Long-term outcome after anterior cervical discectomy without fusion
To retrospectively study the long-term outcome of patients after anterior cervical discectomy without fusion (ACD) compared to results published on the long-term outcome after ACD with fusion (ACDF). We reviewed the charts of all patients receiving ACD surgery between 1985 and 2000 to analyze the direct post-operative results as well as complications of the surgery. Moreover, 102 patients, randomly selected, were interviewed with the neck disability index to study possible persisting complaints up to 18Â years after ACD surgery. A total of 551 Patients were identified. Two months post-operative follow up at the outpatient clinic revealed that 90.1% of patients were satisfied with the result of ACD surgery. At the time of the survey, this percentage had dropped to 67.6%. In addition, 20.6% and 11.8% had obtained moderate to severe complaints, respectively, in daily-life activities. Complaints were mainly localized in the neck region and occasionally provoked radiating pain in the arm. On the short term, ACD leads to a satisfied outcome. Over the longer term, patients report increasing complaints. The increase in complaints at the time of the survey may be the result of ongoing degenerative effects. Compared to published data on ACDF, there is no superiority of any fusion technique compared to ACD alone
Update on cervical disc arthroplasty: where are we and where are we going?
Despite the very good results of anterior cervical discectomy and fusion, there are concerns of adjacent level degeneration. For this reason, interest has grown in the potential for motion sparing alternatives. Cervical disc arthroplasty is thus evolving as a potential alternative to fusion. Specific design characteristic and implants will be reviewed and outcomes summarized
Nutrient Availability as a Mechanism for Selection of Antibiotic Tolerant Pseudomonas aeruginosa within the CF Airway
Microbes are subjected to selective pressures during chronic infections of host tissues. Pseudomonas aeruginosa isolates with inactivating mutations in the transcriptional regulator LasR are frequently selected within the airways of people with cystic fibrosis (CF), and infection with these isolates has been associated with poorer lung function outcomes. The mechanisms underlying selection for lasR mutation are unknown but have been postulated to involve the abundance of specific nutrients within CF airway secretions. We characterized lasR mutant P. aeruginosa strains and isolates to identify conditions found in CF airways that select for growth of lasR mutants. Relative to wild-type P. aeruginosa, lasR mutants exhibited a dramatic metabolic shift, including decreased oxygen consumption and increased nitrate utilization, that is predicted to confer increased fitness within the nutrient conditions known to occur in CF airways. This metabolic shift exhibited by lasR mutants conferred resistance to two antibiotics used frequently in CF care, tobramycin and ciprofloxacin, even under oxygen-dependent growth conditions, yet selection for these mutants in vitro did not require preceding antibiotic exposure. The selection for loss of LasR function in vivo, and the associated adverse clinical impact, could be due to increased bacterial growth in the oxygen-poor and nitrate-rich CF airway, and from the resulting resistance to therapeutic antibiotics. The metabolic similarities among diverse chronic infection-adapted bacteria suggest a common mode of adaptation and antibiotic resistance during chronic infection that is primarily driven by bacterial metabolic shifts in response to nutrient availability within host tissues
The dynamic geophysical environment of (101955) Bennu based on OSIRIS-REx measurements
The top-shaped morphology characteristic of asteroid (101955) Bennu, often found among fast-spinning asteroids and binary asteroid primaries, may have contributed substantially to binary asteroid formation. Yet a detailed geophysical analysis of this morphology for a fast-spinning asteroid has not been possible prior to the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) mission. Combining the measured Bennu mass and shape obtained during the Preliminary Survey phase of the OSIRIS-REx mission, we find a notable transition in Bennuâs surface slopes within its rotational Roche lobe, defined as the region where material is energetically trapped to the surface. As the intersection of the rotational Roche lobe with Bennuâs surface has been most recently migrating towards its equator (given Bennuâs increasing spin rate), we infer that Bennuâs surface slopes have been changing across its surface within the last million years. We also find evidence for substantial density heterogeneity within this body, suggesting that its interior is a mixture of voids and boulders. The presence of such heterogeneity and Bennuâs top shape are consistent with spin-induced failure at some point in its past, although the manner of its failure cannot yet be determined. Future measurements by the OSIRIS-REx spacecraft will provide insight into and may resolve questions regarding the formation and evolution of Bennuâs top-shape morphology and its link to the formation of binary asteroids
Evidence for widespread hydrated minerals on asteroid (101955) Bennu
Early spectral data from the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer (OSIRIS-REx) mission reveal evidence for abundant hydrated minerals on the surface of near-Earth asteroid (101955) Bennu in the form of a near-infrared absorption near 2.7â”m and thermal infrared spectral features that are most similar to those of aqueously altered CM-type carbonaceous chondrites. We observe these spectral features across the surface of Bennu, and there is no evidence of substantial rotational variability at the spatial scales of tens to hundreds of metres observed to date. In the visible and near-infrared (0.4 to 2.4â”m) Bennuâs spectrum appears featureless and with a blue (negative) slope, confirming previous ground-based observations. Bennu may represent a class of objects that could have brought volatiles and organic chemistry to Earth
Study design: Evaluating geneâenvironment interactions in the etiology of breast cancer â the WECARE study
Cervical disc prosthesis replacement and interbody fusion â a comparative study
The purpose of this paper is to compare the new functional intervertebral cervical disc prosthesis replacement and the classical interbody fusion operation, including the clinical effect and maintenance of the stability and segmental motion of cervical vertebrae. Twenty-four patients with single C5-6 intervertebral disk hernias were specifically selected and divided randomly into two groups: One group underwent artificial cervical disc replacement and the other group received interbody fusion. All patients were followed up and evaluated. The operation time for the single disc replacement was (130â±â50) minutes and interbody fusion was (105â±â53) minutes. Neurological or vascular complications were not observed during or after operation. There was no prosthesis subsidence or extrusion. The JOA score of the group with prosthesis replacement increased from an average of 8.6 to 15.8. The JOA score of the group with interbody fusion increased from an average of 9 to 16.2. The clinical effect and the ROM of the adjacent space of the two groups showed no statistical difference. The short follow-up time does not support the advantage of the cervical disc prosthesis. The clinical effect and the maintenance of the function of the motion of the intervertebral space are no better than the interbody fusion. At least 5 years of follow-up is needed to assess the long-term functionality of the prosthesis and the influence on adjacent levels
Disc prosthesis replacement and interbody fusion in the treatment of degenerative cervical disc disease: comparative analysis of 176 consecutive cases
Effects of a cervical disc prosthesis on maintaining sagittal alignment of the functional spinal unit and overall sagittal balance of the cervical spine
The object of this study is to review the early clinical results and radiographic outcomes following insertion of the Bryan Cervical Disc Prosthesis (Medtronic Sofamor Danek, Memphis, TN), together with its effect on maintaining sagittal alignment of the functional spinal unit (FSU) and overall sagittal balance of the cervical spine for the treatment of single-level or two-level symptomatic disc disease. Forty-seven patients with symptomatic single or two-level cervical disc disease who received the Bryan Cervical Artificial Disc were reviewed prospectively. A total of 55 Bryan disc were placed in 47 patients. A single-level procedure was performed in 39 patients and a two-level procedure in the other eight. Radiographic and clinical assessments were made preoperatively and at 1.5, 3, 6, 9, 12, and 18 and up to 33 months postoperatively. Mean follow-up duration was 24 months, ranging from 13 to 33 months. Periods were categorized as early follow up (1.5â3 months) and late follow up (6â33 months). The visual analogue scale (VAS), neck disability index(NDI), Odomâs criteria were used to assess pain and clinical outcomes. Static and dynamic radiographs were measured by hand and computer to determine the range of motion (ROM), the angle of the functional segmental unit (FSU), and the overall cervical alignment (C2â7 Cobb angle). With all of these data, we evaluated the change of the preoperative lordosis (or kyphosis) of the FSU and Overall sagittal balance of the cervical spine during the follow-up period. There was a statistically significant improvement in the VAS score from 7.0 ± 2.6 to 2.0 ± 1.5 (paired-t test, P = 0.000), and in the NDI from 21.5 ± 5.5 to 4.5 ± 3.9 (paired-t test P = 0.000). All of the patients were satisfied with the surgical results by Odomâs criteria. The postoperative ROM of the implanted level was preserved without significant difference from preoperative ROM of the operated level. Only 36% of patients with a preoperative lordotic sagittal orientation of the FSU were able to maintain lordosis following surgery. However, the overall sagittal alignment of the cervical spine was preserved in 86% of cases at the final follow up. Interestingly, preoperatively kyphotic FSU resulted in lordotic FSU in 13% of patients during the late follow-up, and preoperatively kyphotic overall cervical alignment resulted in lordosis in 33% of the patients postoperatively. Clinical results are encouraging, with significant improvement seen in the Bryan Cervical Artificial disc. The Bryan disc preserves motion of the FSU. Although the preoperative lordosis (or kyphosis) of the FSU could not always be maintained during the follow-up period, the overall sagittal balance of the cervical spine was usually preserved