77 research outputs found

    Indication on the universal hadron substructure - constituent quarks

    Full text link
    The universality of single-spin asymmetry on inclusive pi-meson production is discussed. This universality can be related to the hadron substructure - constituent quarks.Comment: 3 pages, 3 figures, references adde

    Goniometer control

    Get PDF
    The control unit for the goniometer has been developed and manufactured. The unit includes four independent programmable stepper motor control channels, three logical channels for analyzing the state of limit switches and a power supply. Powerful field-effect transistors of the company International Rectifier are used as controlled power switches. To generate output signals and communicate with a computer, an ATmega328 microprocessor is used in each control channel. This channel design allows you to control almost any type of stepper motors, you only need to replace the control program. The software is written using the WinAVR package which has a General Public License. Data transfer between the computer and the unit is carried out via the USB interface.Розроблено та виготовлено блок управління гоніометром. До складу блоку входять чотири незалежних програмованих канали керування кроковими двигунами, три логічних канали аналізу стану кінцевих вимикачів та джерело електроживлення. В якості керованих силових ключів використовуються потужні польові транзистори фірми International Rectifier. Для формування вихідних сигналів і зв’язку з комп’ютером у кожному каналі управління використовується мікропроцесор ATmega328. Така побудова каналу дозволяє управляти практично будь-яким типом крокових двигунів, потрібно тільки замінити програму управління. Програмне забезпечення написано з використанням пакета WinAVRб який має General Public License. Передача даних між комп’ютером та блоком здійснюється за допомогою USB-інтерфейсу.Разработан и изготовлен блок управления гониометром. В состав блока входят четыре независимых программируемых канала управления шаговыми двигателями, три логических канала анализа состояния конечных выключателей и источник электропитания. В качестве управляемых силовых ключей используются мощные полевые транзисторы фирмы International Rectifier. Для формирования выходных сигналов и связи с компьютером в каждом канале управления используется микропроцессор ATmega328. Такое построение канала позволяет управлять практически любым типом шаговых двигателей, требуется только заменить программу управления. Программное обеспечение написано с использованием пакета WinAVR, имеющего General Public License. Передача данных между компьютером и блоком осуществляется по USB-интерфейсу

    Method for express determination of medical radionuclides ⁹⁹ᵐTc, ⁶⁷Cu concentration using spectrometer based on Si planar detector

    No full text
    The method of express analysis provides the measurement of radiation spectra of medical radionuclides by a detection module based on an uncooled silicon planar detector and a "scintillator-silicon photosensor" type module. A spectrometric device for express analysis of radionuclide concentration has been developed and its prototyping has been carried out, confirming the operability of the device. The spectrometer analyzer is powered from the USB port of the PC (including a laptop) that provides the possibility of autonomous operation. Test measurements were carried out using the prototype of the spectrometer and X-ray sources, as well as spectral distributions of the radiation of real samples of ⁹⁹ᵐTc in a special container (glass ampoule). For a Si-PIN-detector with a thickness of 300 μm, the emission spectrum consists of a line of ⁹⁹ᵐTc with an energy of 140.5 keV and two peaks of the characteristic X-ray radiation (CXR) of technetium. The calculation in GEANT4 shows the matching of the ⁹⁹ᵐTc activities obtained from the registration of CXR and the main line. A measurement of the technetium concentration both by the 140.5 keV line and on the CXR radiation was proposed that significantly increases the speed of the data accumulation.Методика експрес-аналізу передбачає вимір спектрів випромінювання медичних радіонуклідів детектуючим модулем на основі неохолоджуваного кремнієвого планарного детектора і модулем типу «сцинтилятор - кремнієвий фотосенсор». Розроблено спектрометричний пристрій для експрес-аналізу концентрації радіонуклідів і проведено його макетування, що підтверджує працездатність пристрою. Живлення спектрометра-аналізатора виконано від USB-порту ПК (в тому числі, ноутбука), що забезпечує можливість автономної роботи. Проведено тестові вимірювання з використанням робочого макета спектрометра і джерел рентгенівського випромінювання, а також досліджені спектральні розподіли випромінювання реальних зразків ⁹⁹ᵐТc у спеціальній упаковці (скляній ампулі). Для Si-PIN-детектора товщиною 300 мкм спектр випромінювання складається з лінії ⁹⁹ᵐТc з енергією 140,5 кеВ і двох піків характеристичного рентгенівського випромінювання технеція. Розрахунок у GEANT4 показує узгодження активностей ⁹⁹ᵐТc, отриманих по реєстрації ХРВ і основної лінії. Запропоновано вимірювання концентрації технеція не тільки по лінії 140,5 кеВ, а й по випромінюванню ХРВ, що істотно збільшує швидкість набору даних.Методика экспресс-анализа предусматривает измерение спектров излучения медицинских радионуклидов детектирующим модулем на основе неохлаждаемого кремниевого планарного детектора и модулем типа «сцинтиллятор - кремниевый фотосенсор». Разработано спектрометрическое устройство для экспресс-анализа концентрации радионуклидов и проведено его макетирование, подтверждающее работоспособность устройства. Питание спектрометра-анализатора выполнено от USB-порта ПК (в том числе, ноутбука), что обеспечивает возможность автономной работы. Проведены тестовые измерения с использованием рабочего макета спектрометра и источников рентгеновского излучения, а также исследованы спектральные распределения излучения реальных образцов ⁹⁹ᵐТс в специальной упаковке (стеклянной ампуле). Для Si-PIN-детектора толщиной 300 мкм спектр излучения состоит из линии ⁹⁹ᵐТс с энергией 140,5 кэВ и двух пиков характеристичного рентгеновского излучения технеция. Расчет в GEANT4 показывает согласие активностей ⁹⁹ᵐТc, полученных по регистрации ХРИ и основной линии. Предложено измерение концентрации технеция не только по линии 140,5 кэВ, но и по излучению ХРИ, что существенно увеличивает скорость набора данных

    Superparticle Models with Tensorial Central Charges

    Get PDF
    A generalization of the Ferber-Shirafuji formulation of superparticle mechanics is considered. The generalized model describes the dynamics of a superparticle in a superspace extended by tensorial central charge coordinates and commuting twistor-like spinor variables. The D=4 model contains a continuous real parameter a0a\geq 0 and at a=0 reduces to the SU(2,2|1) supertwistor Ferber-Shirafuji model, while at a=1 one gets an OSp(1|8) supertwistor model of ref. [1] (hep-th/9811022) which describes BPS states with all but one unbroken target space supersymmetries. When 0<a<1 the model admits an OSp(2|8) supertwistor description, and when a>1 the supertwistor group becomes OSp(1,1|8). We quantize the model and find that its quantum spectrum consists of massless states of an arbitrary (half)integer helicity. The independent discrete central charge coordinate describes the helicity spectrum. We also outline the generalization of the a=1 model to higher space-time dimensions and demonstrate that in D=3,4,6 and 10, where the quantum states are massless, the extra degrees of freedom (with respect to those of the standard superparticle) parametrize compact manifolds. These compact manifolds can be associated with higher-dimensional helicity states. In particular, in D=10 the additional ``helicity'' manifold is isomorphic to the seven-sphere.Comment: 32 pages, LATEX, no figure

    Spectrometric stand for measuring the energy resolution of unpackaged elements of silicon planar detectors

    Get PDF
    A spectrometric stand for measuring the energy resolution of unpackaged single-channel silicon planar detectors has been developed and manufactured. The developed spectrometric stand makes it possible to reject detectors with unsatisfactory spectrometric characteristics at an early stage of manufacturing the detecting modules. Also, a technique has been developed for studying the spectrometric characteristics of unpackaged silicon detectors intended for the manufacture of detecting modules for ionizing radiation for various purposes.Розроблено та виготовлено спектрометричний стенд для вимірювання енергетичної роздільної здатності безкорпусних одноканальних кремнієвих планарних детекторів. Розроблений спектрометричний стенд дозволяє на ранній стадії виготовлення детектуючих модулів бракувати детектори з незадовільними спектрометричними характеристиками. Також розроблена методика дослідження спектрометричних характеристик безкорпусних кремнієвих детекторів, призначених для виготовлення детектуючих модулів іонізуючого випромінювання різного призначення.Разработан и изготовлен спектрометрический стенд для измерения энергетического разрешения бескорпусных одноканальных кремниевых планарных детекторов. Разработанный спектрометрический стенд позволяет на ранней стадии изготовления детектирующих модулей отбраковывать детекторы с неудовлетворительными спектрометрическими характеристиками. Также разработана методика исследования спектрометрических характеристик бескорпусных кремниевых детекторов, предназначенных для изготовления детектирующих модулей ионизирующего излучения различного назначения

    Development of a portable gamma probe for registration and localization of radiation source, including medical application

    Get PDF
    Self-powered portable gamma probe has been developed on the base of silicon planar uncooled detector and CsI(Tl) scintillator. The device is designed for interoperative and extraoperative search for differences in the concentration of radiopharmaceuticals in the energy range from 100 to 360 keV. Test stand was developed for determining the angular resolution of the gamma probe.На базі кремнієвого планарного неохолоджуваного детектора і сцинтилятора СsI(Tl) розроблений портативний гамма-зонд з автономним живленням. Прилад розрахований на інтероперативний та екстраоперативний пошуки відмінностей у концентрації радіофармацевтичних препаратів у енергетичному діапазоні 100 до 360 кеВ. Розроблено тестовий стенд для визначення кутового розподілу гамма-зонда

    Kharkiv test platform for research and development of Si spectrometric planar detectors and detectors arrays for medical application

    Get PDF
    A universal test platform for research and development of planar radiation detectors for use in medicine has been created having the possibility of obtaining complete information about the characteristics of the detector before creating a detecting module with specialized electronics. 5 jobs were created with the ability to perform the following work: measurement of the electrophysical characteristics of individual detectors and selected detection elements of the matrices based on the station with manual movement of microprobes; determination of the yield of suitable detector elements of matrices using a test station with automated microprobe movement and automated collection and processing of electrophysical measurement data; measurement of the energy resolution (ER) of individual silicon detectors, “scintillator-silicon photosensor” type detectors and measurement of the ER of selected matrix elements before creating a detection module with specialized electronics.Створена універсальна тестова платформа для досліджень і розробки планарних детекторів випромінювання для використань в медицині з можливістю отримання повної інформації про характеристики детектора та матриці детекторів до створення детектуючого модуля зі спеціалізованою електронікою. Створено 5 робочих місць з можливістю виконання наступних робіт: вимірювання електрофізичних характеристик окремих детекторів і обраних детектуючих елементів матриць на основі станції з ручним переміщенням мікрозондів; визначення виходу придатних детекторних елементів матриць з використанням тестової станції з автоматизованим переміщенням мікрозондів і автоматизованим накопиченням і обробкою даних електрофізичних вимірювань; вимірювання енергетичної роздільної здатності (ЕРЗ) окремих кремнієвих детекторів, детекторів типу «сцинтилятор-кремнієвий фотосенсор» і вимір ЕРЗ обраних елементів матриць до створення детектуючого модуля зі спеціалізованою електронікою.Создана универсальная тестовая платформа для исследований и разработки планарных детекторов излучения для использования в медицине с возможностью получения полной информации о характеристиках детектора и матриц детекторов для создания детектирующего модуля со специализированной электроникой. Созданы 5 рабочих мест с возможностью выполнения следующих работ: измерение электрофизических характеристик отдельных детекторов и выбранных детектирующих элементов матриц на основе станции с ручным перемещением микрозондов; определение выхода годных детекторных элементов матриц с использованием тестовой станции с автоматизированным перемещением микрозондов и автоматизированным накоплением и обработкой данных электрофизических измерений; измерение энергетического разрешения (ЭР) отдельных кремниевых детекторов, детекторов типа «сцинтиллятор-кремниевый фотосенсор» и измерение ЭР выбранных элементов матриц для создания детектирующего модуля со специализированной электроникой

    Equations of Motion for Massive Spin 2 Field Coupled to Gravity

    Get PDF
    We investigate the problems of consistency and causality for the equations of motion describing massive spin two field in external gravitational and massless scalar dilaton fields in arbitrary spacetime dimension. From the field theoretical point of view we consider a general classical action with non-minimal couplings and find gravitational and dilaton background on which this action describes a theory consistent with the flat space limit. In the case of pure gravitational background all field components propagate causally. We show also that the massive spin two field can be consistently described in arbitrary background by means of the lagrangian representing an infinite series in the inverse mass. Within string theory we obtain equations of motion for the massive spin two field coupled to gravity from the requirement of quantum Weyl invariance of the corresponding two dimensional sigma-model. In the lowest order in α\alpha' we demonstrate that these effective equations of motion coincide with consistent equations derived in field theory.Comment: 27 pages, LaTeX file, journal versio
    corecore