736 research outputs found

    Fast and accurate Slicewise OutLIer Detection (SOLID) with informed model estimation for diffusion MRI data

    Get PDF
    The accurate characterization of the diffusion process in tissue using diffusion MRI is greatly challenged by the presence of artefacts. Subject motion causes not only spatial misalignments between diffusion weighted images, but often also slicewise signal intensity errors. Voxelwise robust model estimation is commonly used to exclude intensity errors as outliers. Slicewise outliers, however, become distributed over multiple adjacent slices after image registration and transformation. This challenges outlier detection with voxelwise procedures due to partial volume effects. Detecting the outlier slices before any transformations are applied to diffusion weighted images is therefore required. In this work, we present i) an automated tool coined SOLID for slicewise outlier detection prior to geometrical image transformation, and ii) a framework to naturally interpret data uncertainty information from SOLID and include it as such in model estimators. SOLID uses a straightforward intensity metric, is independent of the choice of the diffusion MRI model, and can handle datasets with a few or irregularly distributed gradient directions. The SOLID-informed estimation framework prevents the need to completely reject diffusion weighted images or individual voxel measurements by downweighting measurements with their degree of uncertainty, thereby supporting convergence and well-conditioning of iterative estimation algorithms. In comprehensive simulation experiments, SOLID detects outliers with a high sensitivity and specificity, and can achieve higher or at least similar sensitivity and specificity compared to other tools that are based on more complex and time-consuming procedures for the scenarios investigated. SOLID was further validated on data from 54 neonatal subjects which were visually inspected for outlier slices with the interactive tool developed as part of this study, showing its potential to quickly highlight problematic volumes and slices in large population studies. The informed model estimation framework was evaluated both in simulations and in vivo human data.Peer reviewe

    Helium-3 and Helium-4 acceleration by high power laser pulses for hadron therapy

    Full text link
    The laser driven acceleration of ions is considered a promising candidate for an ion source for hadron therapy of oncological diseases. Though proton and carbon ion sources are conventionally used for therapy, other light ions can also be utilized. Whereas carbon ions require 400 MeV per nucleon to reach the same penetration depth as 250 MeV protons, helium ions require only 250 MeV per nucleon, which is the lowest energy per nucleon among the light ions. This fact along with the larger biological damage to cancer cells achieved by helium ions, than that by protons, makes this species an interesting candidate for the laser driven ion source. Two mechanisms (Magnetic Vortex Acceleration and hole-boring Radiation Pressure Acceleration) of PW-class laser driven ion acceleration from liquid and gaseous helium targets are studied with the goal of producing 250 MeV per nucleon helium ion beams that meet the hadron therapy requirements. We show that He3 ions, having almost the same penetration depth as He4 with the same energy per nucleon, require less laser power to be accelerated to the required energy for the hadron therapy.Comment: 8 pages, 3 figures, 1 tabl

    Radiation Pressure Acceleration: the factors limiting maximum attainable ion energy

    Full text link
    Radiation pressure acceleration (RPA) is a highly efficient mechanism of laser-driven ion acceleration, with with near complete transfer of the laser energy to the ions in the relativistic regime. However, there is a fundamental limit on the maximum attainable ion energy, which is determined by the group velocity of the laser. The tightly focused laser pulses have group velocities smaller than the vacuum light speed, and, since they offer the high intensity needed for the RPA regime, it is plausible that group velocity effects would manifest themselves in the experiments involving tightly focused pulses and thin foils. However, in this case, finite spot size effects are important, and another limiting factor, the transverse expansion of the target, may dominate over the group velocity effect. As the laser pulse diffracts after passing the focus, the target expands accordingly due to the transverse intensity profile of the laser. Due to this expansion, the areal density of the target decreases, making it transparent for radiation and effectively terminating the acceleration. The off-normal incidence of the laser on the target, due either to the experimental setup, or to the deformation of the target, will also lead to establishing a limit on maximum ion energy.Comment: 17 pages, 6 figure

    Enhancing proton acceleration by using composite targets

    Full text link
    Efficient laser ion acceleration requires high laser intensities, which can only be obtained by tightly focusing laser radiation. In the radiation pressure acceleration regime, where the tightly focused laser driver leads to the appearance of the fundamental limit for the maximum attainable ion energy, this limit corresponds to the laser pulse group velocity as well as to another limit connected with the transverse expansion of the accelerated foil and consequent onset of the foil transparency. These limits can be relaxed by using composite targets, consisting of a thin foil followed by a near critical density slab. Such targets provide guiding of a laser pulse inside a self-generated channel and background electrons, being snowplowed by the pulse, compensate for the transverse expansion. The use of composite targets results in a significant increase in maximum ion energy, compared to a single foil target case.Comment: 16 pages, 9 figure

    Laser-heater assisted plasma channel formation in capillary discharge waveguides

    Full text link
    A method of creating plasma channels with controllable depth and transverse profile for the guiding of short, high power laser pulses for efficient electron acceleration is proposed. The plasma channel produced by the hydrogen-filled capillary discharge waveguide is modified by a ns-scale laser pulse, which heats the electrons near the capillary axis. This interaction creates a deeper plasma channel within the capillary discharge that evolves on a ns-time scale, allowing laser beams with smaller spot sizes than would otherwise be possible in the unmodified capillary discharge.Comment: 5 pages, 3 figure

    Infrahyoid fascio-myocutaneous flap as an alternative to free radial forearm flap in head and neck reconstruction.

    Get PDF
    The use of microvascular free flaps is currently the favored method for the reconstruction of defects after resection of head and neck cancer. The flap most commonly used for head and neck reconstruction is the free radial forearm flap, but the less popular infrahyoid flap represents a good alternative in selected cases. This flap has proven to be helpful in the reconstruction of a wide range of moderate-sized head and neck defects.We reviewed a series of 13 patients with defects resulting from cancer of the head and neck, who underwent infrahyoid flap reconstruction as an alternative to free radial forearm flap. The series includes 12 squamous cell carcinomas arising from the oral cavity and oropharynx, and 1 Merkel cell carcinoma of the submental skin. In the harvesting of the flap, the technical modifications recently suggested by Dolivet et al were used in all cases. Furthermore, another technical change has been introduced so creating a new infrahyoid facio-myocutaneous flap (IHFMCF). The surgical technique is described in detail.No total or partial flap necrosis was experienced. All reconstructions healed quickly without wound complications and with good functional results. The healing process in the donor site was excellent in every case with good aesthetic results.The IHFMCF is a versatile, reliable, and convenient flap suitable for repairing small and medium-sized defects of the oral cavity and oropharynx and obviates the need for a microvascular reconstruction

    On the design of experiments to study extreme field limits

    Full text link
    We propose experiments on the collision of high intensity electromagnetic pulses with electron bunches and on the collision of multiple electromagnetic pulses for studying extreme field limits in the nonlinear interaction of electromagnetic waves. The effects of nonlinear QED will be revealed in these laser plasma experiments.Comment: 7 pages, 3 figures, 1 table; 15th Advanced Accelerator Concepts Workshop (AAC 2012), Austin, Texas, 10-15 June, 201

    On production and asymmetric focusing of flat electron beams using rectangular capillary discharge plasmas

    Full text link
    A method for the asymmetric focusing of electron bunches, based on the active plasma lensing technique is proposed. This method takes advantage of the strong inhomogeneous magnetic field generated inside the capillary discharge plasma to focus the ultrarelativistic electrons. The plasma and magnetic field parameters inside the capillary discharge are described theoretically and modeled with dissipative magnetohydrodynamic computer simulations enabling analysis of the capillaries of rectangle cross-sections. Large aspect ratio rectangular capillaries might be used to transport electron beams with high emittance asymmetries, as well as assist in forming spatially flat electron bunches for final focusing before the interaction point.Comment: 16 pages, 7 figures, 1 tabl
    corecore