39 research outputs found

    Blood pressure changes after renal denervation at 10 European expert centers

    Get PDF
    We did a subject-level meta-analysis of the changes (Δ) in blood pressure (BP) observed 3 and 6 months after renal denervation (RDN) at 10 European centers. Recruited patients (n=109; 46.8% women; mean age 58.2 years) had essential hypertension confirmed by ambulatory BP. From baseline to 6 months, treatment score declined slightly from 4.7 to 4.4 drugs per day. Systolic/diastolic BP fell by 17.6/7.1 mm Hg for office BP, and by 5.9/3.5, 6.2/3.4, and 4.4/2.5 mm Hg for 24-h, daytime and nighttime BP (P0.03 for all). In 47 patients with 3- and 6-month ambulatory measurements, systolic BP did not change between these two time points (P0.08). Normalization was a systolic BP of <140 mm Hg on office measurement or <130 mm Hg on 24-h monitoring and improvement was a fall of 10 mm Hg, irrespective of measurement technique. For office BP, at 6 months, normalization, improvement or no decrease occurred in 22.9, 59.6 and 22.9% of patients, respectively; for 24-h BP, these proportions were 14.7, 31.2 and 34.9%, respectively. Higher baseline BP predicted greater BP fall at follow-up; higher baseline serum creatinine was associated with lower probability of improvement of 24-h BP (odds ratio for 20-μmol l(-1) increase, 0.60; P=0.05) and higher probability of experiencing no BP decrease (OR, 1.66; P=0.01). In conclusion, BP responses to RDN include regression-to-the-mean and remain to be consolidated in randomized trials based on ambulatory BP monitoring. For now, RDN should remain the last resort in patients in whom all other ways to control BP failed, and it must be cautiously used in patients with renal impairment

    Detection of human bocavirus and human metapneumovirus by real-time PCR from patients with respiratory symptoms in Southern Brazil

    Get PDF
    The introduction of newer molecular methods has led to the discovery of new respiratory viruses, such as human metapneumovirus (hMPV) and human bocavirus (hBoV), in respiratory tract specimens. We have studied the occurrence of hMPV and hBoV in the Porto Alegre (PA) metropolitan area, one of the southernmost cities of Brazil, evaluating children with suspected lower respiratory tract infection from May 2007-June 2008. A real-time polymerase chain reaction method was used for amplification and detection of hMPV and hBoV and to evaluate coinfections with respiratory syncytial virus (RSV), influenza A and B, parainfluenza 1, 2 and 3, human rhinovirus and human adenovirus. Of the 455 nasopharyngeal aspirates tested, hMPV was detected in 14.5% of samples and hBoV in 13.2%. A unique causative viral agent was identified in 46.2% samples and the coinfection rate was 43.7%. For hBoV, 98.3% of all positive samples were from patients with mixed infections. Similarly, 84.8% of all hMPV-positive results were also observed in mixed infections. Both hBoV and hMPV usually appeared with RSV. In summary, this is the first confirmation that hMPV and hBoV circulate in PA; this provides evidence of frequent involvement of both viruses in children with clinical signs of acute viral respiratory tract infection, although they mainly appeared as coinfection agents

    Investigating the effect of artists’ paint formulation on degradation rates of TiO2-based oil paints

    Get PDF
    This study reports on the effect of artists’ paint formulation on degradation rates of TiO2-based oil paints. Titanium white oil paint exists in a multitude of different recipes, and the effect of the formulation on photocatalytic binder degradation kinetics is unknown. These formulations contain, among others, one or both titanium dioxide polymorphs, zinc oxide, the extenders barium sulfate or calcium carbonate and various additives. Most research performed on the photocatalytic degradation process focusses on pure titanium white-binder mixtures and thus does not take into account the complete paint system. Since photocatalytic oil degradation is a process initiated by the absorption of UV light, any ingredient or combination of ingredients influencing the light scattering and absorption properties of the paint films may affect the degradation rate. In this study three sets of experiments are conducted, designed using the design of experiments (DoE) approach, to screen for the most important formulation factors influencing the degradation rate. The benefits of using DoE, compared to a more traditional ‘one factor at a time approach’ are robustness, sample efficiency, the ability of evaluate mixtures of multiple components as well as the ability to evaluate factor interactions. The three sets of experiments investigate (1) the influence of the TiO2 type, (2) the impact of different mixtures of two types of TiO2, ZnO and the additive aluminum stearate and (3) the influence of common extenders in combination with photocatalytic TiO2, on the photocatalytic degradation of the oil binder. The impact of the formulation on the degradation rate became apparent, indicating the shortcoming of oversimplified studies. The protective effect of photostable TiO2 pigments, even in a mixture with photocatalytic TiO2 pigments, as well as the negative effect of extenders was demonstrated. Furthermore, the ambiguous role of ZnO (photocatalytic or not) and aluminum stearate is highlighted. Neither can be ignored in a study of degradation behavior of modern oil paints and require further investigation

    Rapid characterisation of mixtures of hydrogen and natural gas by means of ultrasonic time-delay estimation

    Get PDF
    The implementation of the “power-to-gas” concept, where hydrogen and natural gas are blended and transported in the existing network, requires a quick, on-site method to monitor the content of hydrogen in the mixture. We evaluate a rapid characterisation of this mixture based on the measurement of the speed of sound, using micromachined ultrasonic transducers (MUTs). Two MUT-based prototypes were implemented to analyse a mixture of natural gas and hydrogen under controlled conditions. Changes in the hydrogen content below 2 mol % (in a mixture that was adjusted between 6 mol % and 16 mol %) were discriminated by both devices, including the uncertainty due to the temperature compensation and the time-delay estimation. The obtained values of the speed of sound were consistent with those calculated from independent, non-acoustic measurements performed with a gas chromatograph and a density sensor. An MUT-based flow meter is thus capable of reporting both gas intake and the molar fraction of hydrogen, provided that the source of natural gas is kept constant.</p

    Long term outcome after treatment of de novo coronary artery lesions using three different drug coated balloons

    No full text
    Objective: To evaluate the long-term efficacy of three currently available drug coated balloons (DCB) for the treatment of de-novo coronary lesions. Methods: This was a retrospective analysis of prospectively collected data from the Swedish Coronary Angiography and Angioplasty Registry. Between 2009 and 2017, three currently available DCB brands used in the treatment of de novo lesions were included. Outcomes were clinically driven restenosis and target lesion thrombosis (TLT) (per device) and major adverse cardiac events (MACE) including death, myocardial infarction or target vessel revascularization (per patient) at 4 years. Multivariable Cox regression models were used to adjust for differences. Results: We included 6715 lesions treated with DCBs, 4483 SeQuent® Please (S-DCB), 1071 IN.PACT Falcon (I-DCB) and 1161 Pantera® Lux (P-DCB), in 5670 patients. The mean DCB diameter was 2.4 mm. Bailout stenting occurred in 6.7% of lesions. Angiographic success was 98.5%. The overall cumulative rate of restenosis was 5.5% (299 events). The risk for reported restenosis did not significantly differ between I-DCB vs S-DCB, adjusted hazard ratio (aHR) 0.96; 95% confidence interval (CI) 0.69–1.34, P-DCB vs S-DCB aHR 0.88; 95% CI 0.63–1.23 and I-DCB vs P-DCB aHR 1.10; 95% CI 0.72–1.68. The cumulative risk for TLT was 0.8% in all three DCBs. The risk for MACE or individual components of MACE did not differ between the three patient-groups. Conclusion: In de novo coronary lesions, we found comparable long-term efficacy with three currently available DCB brands. DCB angioplasty was feasible with low risk for long-term restenosis and TLT

    Routine Oxygen Therapy Does Not Improve Health-Related Quality of Life in Patients With Acute Myocardial Infarction—Insights From the Randomized DETO2X-AMI Trial

    No full text
    Background: After decades of ubiquitous oxygen therapy in all patients with acute myocardial infarction (MI), recent guidelines are more restrictive based on lack of efficacy in contemporary trials evaluating hard clinical outcomes in patients without hypoxemia at baseline. However, no evidence regarding treatment effects on health-related quality of life (HRQoL) exists. In this study, we investigated the impact of routine oxygen supplementation on HRQoL 6–8 weeks after hospitalization with acute MI. Secondary objectives included analyses of MI subtypes, further adjustment for infarct size, and oxygen saturation at baseline and 1-year follow-up. Methods: In the DETermination of the role of Oxygen in suspected Acute Myocardial Infarction (DETO2X-AMI) trial, 6,629 normoxemic patients with suspected MI were randomized to oxygen at 6 L/min for 6–12 h or ambient air. In this prespecified analysis, patients younger than 75 years of age with confirmed MI who had available HRQoL data by European Quality of Life Five Dimensions questionnaire (EQ-5D) in the national registry were included. Primary endpoint was the EQ-5D index assessed by multivariate linear regression at 6–10 weeks after MI occurrence. Results: A total of 3,086 patients (median age 64, 22% female) were eligible, 1,518 allocated to oxygen and 1,568 to ambient air. We found no statistically significant effect of oxygen therapy on EQ-5D index (−0.01; 95% CI: −0.03–0.01; p = 0.23) or EQ-VAS score (−0.57; 95% CI: −1.88–0.75; p = 0.40) compared to ambient air after 6–10 weeks. Furthermore, no significant difference was observed between the treatment groups in EQ-5D dimensions. Results remained consistent across MI subtypes and at 1-year follow-up, including further adjustment for infarct size or oxygen saturation at baseline. Conclusions: Routine oxygen therapy provided to normoxemic patients with acute MI did not improve HRQoL up to 1 year after MI occurrence. Clinical Trial Registration: ClinicalTrials.gov number, NCT01787110.
    corecore