31 research outputs found

    A sex-informed approach to improve the personalised decision making process in myelodysplastic syndromes: a multicentre, observational cohort study

    Get PDF
    Background Sex is a major source of diversity among patients and a sex-informed approach is becoming a new paradigm in precision medicine. We aimed to describe sex diversity in myelodysplastic syndromes in terms of disease genotype, phenotype, and clinical outcome. Moreover, we sought to incorporate sex information into the clinical decision-making process as a fundamental component of patient individuality. Methods In this multicentre, observational cohort study, we retrospectively analysed 13 284 patients aged 18 years or older with a diagnosis of myelodysplastic syndrome according to 2016 WHO criteria included in the EuroMDS network (n=2025), International Working Group for Prognosis in MDS (IWG-PM; n=2387), the Spanish Group of Myelodysplastic Syndromes registry (GESMD; n=7687), or the Dusseldorf MDS registry (n=1185). Recruitment periods for these cohorts were between 1990 and 2016. The correlation between sex and genomic features was analysed in the EuroMDS cohort and validated in the IWG-PM cohort. The effect of sex on clinical outcome, with overall survival as the main endpoint, was analysed in the EuroMDS population and validated in the other three cohorts. Finally, novel prognostic models incorporating sex and genomic information were built and validated, and compared to the widely used revised International Prognostic Scoring System (IPSS-R). This study is registered with ClinicalTrials.gov, NCT04889729. Findings The study included 7792 (58middot7%) men and 5492 (41middot3%) women. 10 906 (82middot1%) patients were White, and race was not reported for 2378 (17middot9%) patients. Sex biases were observed at the single-gene level with mutations in seven genes enriched in men (ASXL1, SRSF2, and ZRSR2 p<0middot0001 in both cohorts; DDX41 not available in the EuroMDS cohort vs p=0middot0062 in the IWG-PM cohort; IDH2 p<0middot0001 in EuroMDS vs p=0middot042 in IWG-PM; TET2 p=0middot031 vs p=0middot035; U2AF1 p=0middot033 vs p<0middot0001) and mutations in two genes were enriched in women (DNMT3A p<0middot0001 in EuroMDS vs p=0middot011 in IWG-PM; TP53 p=0middot030 vs p=0middot037). Additionally, sex biases were observed in co-mutational pathways of founding genomic lesions (splicing-related genes, predominantly in men, p<0middot0001 in both the EuroMDS and IWG-PM cohorts), in DNA methylation (predominantly in men, p=0middot046 in EuroMDS vs p<0middot0001 in IWG-PM), and TP53 mutational pathways (predominantly in women, p=0middot0073 in EuroMDS vs p<0middot0001 in IWG-PM). In the retrospective EuroMDS cohort, men had worse median overall survival (81middot3 months, 95% CI 70middot4-95middot0 in men vs 123middot5 months, 104middot5-127middot5 in women; hazard ratio [HR] 1middot40, 95% CI 1middot26-1middot52; p<0middot0001). This result was confirmed in the prospective validation cohorts (median overall survival was 54middot7 months, 95% CI 52middot4-59middot1 in men vs 74middot4 months, 69middot3-81middot2 in women; HR 1middot30, 95% CI 1middot23-1middot35; p<0middot0001 in the GEMSD MDS registry; 40middot0 months, 95% CI 33middot4-43middot7 in men vs 54middot2 months, 38middot6-63middot8 in women; HR 1middot23, 95% CI 1middot08-1middot36; p<0middot0001 in the Dusseldorf MDS registry). We developed new personalised prognostic tools that included sex information (the sex-informed prognostic scoring system and the sex-informed genomic scoring system). Sex maintained independent prognostic power in all prognostic systems; the highest performance was observed in the model that included both sex and genomic information. A five-to-five mapping between the IPSS-R and new score categories resulted in the re-stratification of 871 (43middot0%) of 2025 patients from the EuroMDS cohort and 1003 (42middot0%) of 2387 patients from the IWG-PM cohort by using the sex-informed prognostic scoring system, and of 1134 (56middot0%) patients from the EuroMDS cohort and 1265 (53middot0%) patients from the IWG-PM cohort by using the sex-informed genomic scoring system. We created a web portal that enables outcome predictions based on a sex-informed personalised approach. Interpretation Our results suggest that a sex-informed approach can improve the personalised decision making process in patients with myelodysplastic syndromes and should be considered in the design of clinical trials including low-risk patients. Copyright (c) 2022 Published by Elsevier Ltd. All rights reserved

    The association of indwelling urinary catheter with delirium in hospitalized patients and nursing home residents: an explorative analysis from the "Delirium Day 2015"

    Get PDF
    Backround: Use of indwelling urinary catheter (IUC) in older adults has negative consequences, including delirium. Aim: This analysis, from the "Delirium Day 2015", a nationwide multicenter prevalence study, aim to evaluate the association of IUC with delirium in hospitalized and Nursing Homes (NHs) patients. Methods: Patients underwent a comprehensive geriatric assessment, including the presence of IUC; inclusion criteria were age &gt; 65 years, being Italian speaker and providing informed consent; exclusion criteria were coma, aphasia, end-of-life status. Delirium was assessed using the 4AT test (score ≥ 4: possible delirium; scores 1-3: possible cognitive impairment). Results: Among 1867 hospitalized patients (mean age 82.0 ± 7.5 years, 58% female), 539 (28.9%) had IUC, 429 (22.9%) delirium and 675 (36.1%) cognitive impairment. IUC was significantly associated with cognitive impairment (OR 1.60, 95% CI 1.19-2.16) and delirium (2.45, 95% CI 1.73-3.47), this latter being significant also in the subset of patients without dementia (OR 2.28, 95% CI 1.52-3.43). Inattention and impaired alertness were also independently associated with IUC. Among 1454 NHs residents (mean age 84.4 ± 7.4 years, 70.% female), 63 (4.3%) had IUC, 535 (36.8%) a 4AT score ≥ 4, and 653 (44.9%) a 4AT score 1-3. The multivariate logistic regression analysis did not show a significant association between 4AT test or its specific items with IUC, neither in the subset of patients without dementia. Discussion: We confirmed a significant association between IUC and delirium in hospitalized patients but not in NHs residents. Conclusion: Environmental and clinical factors of acute setting might contribute to IUC-associated delirium occurrence

    &quot;Delirium Day&quot;: A nationwide point prevalence study of delirium in older hospitalized patients using an easy standardized diagnostic tool

    Get PDF
    Background: To date, delirium prevalence in adult acute hospital populations has been estimated generally from pooled findings of single-center studies and/or among specific patient populations. Furthermore, the number of participants in these studies has not exceeded a few hundred. To overcome these limitations, we have determined, in a multicenter study, the prevalence of delirium over a single day among a large population of patients admitted to acute and rehabilitation hospital wards in Italy. Methods: This is a point prevalence study (called "Delirium Day") including 1867 older patients (aged 65 years or more) across 108 acute and 12 rehabilitation wards in Italian hospitals. Delirium was assessed on the same day in all patients using the 4AT, a validated and briefly administered tool which does not require training. We also collected data regarding motoric subtypes of delirium, functional and nutritional status, dementia, comorbidity, medications, feeding tubes, peripheral venous and urinary catheters, and physical restraints. Results: The mean sample age was 82.0 ± 7.5 years (58 % female). Overall, 429 patients (22.9 %) had delirium. Hypoactive was the commonest subtype (132/344 patients, 38.5 %), followed by mixed, hyperactive, and nonmotoric delirium. The prevalence was highest in Neurology (28.5 %) and Geriatrics (24.7 %), lowest in Rehabilitation (14.0 %), and intermediate in Orthopedic (20.6 %) and Internal Medicine wards (21.4 %). In a multivariable logistic regression, age (odds ratio [OR] 1.03, 95 % confidence interval [CI] 1.01-1.05), Activities of Daily Living dependence (OR 1.19, 95 % CI 1.12-1.27), dementia (OR 3.25, 95 % CI 2.41-4.38), malnutrition (OR 2.01, 95 % CI 1.29-3.14), and use of antipsychotics (OR 2.03, 95 % CI 1.45-2.82), feeding tubes (OR 2.51, 95 % CI 1.11-5.66), peripheral venous catheters (OR 1.41, 95 % CI 1.06-1.87), urinary catheters (OR 1.73, 95 % CI 1.30-2.29), and physical restraints (OR 1.84, 95 % CI 1.40-2.40) were associated with delirium. Admission to Neurology wards was also associated with delirium (OR 2.00, 95 % CI 1.29-3.14), while admission to other settings was not. Conclusions: Delirium occurred in more than one out of five patients in acute and rehabilitation hospital wards. Prevalence was highest in Neurology and lowest in Rehabilitation divisions. The "Delirium Day" project might become a useful method to assess delirium across hospital settings and a benchmarking platform for future surveys

    Understanding Factors Associated With Psychomotor Subtypes of Delirium in Older Inpatients With Dementia

    Get PDF

    "Delirium Day": A nationwide point prevalence study of delirium in older hospitalized patients using an easy standardized diagnostic tool

    Get PDF
    Background: To date, delirium prevalence in adult acute hospital populations has been estimated generally from pooled findings of single-center studies and/or among specific patient populations. Furthermore, the number of participants in these studies has not exceeded a few hundred. To overcome these limitations, we have determined, in a multicenter study, the prevalence of delirium over a single day among a large population of patients admitted to acute and rehabilitation hospital wards in Italy. Methods: This is a point prevalence study (called "Delirium Day") including 1867 older patients (aged 65 years or more) across 108 acute and 12 rehabilitation wards in Italian hospitals. Delirium was assessed on the same day in all patients using the 4AT, a validated and briefly administered tool which does not require training. We also collected data regarding motoric subtypes of delirium, functional and nutritional status, dementia, comorbidity, medications, feeding tubes, peripheral venous and urinary catheters, and physical restraints. Results: The mean sample age was 82.0 \ub1 7.5 years (58 % female). Overall, 429 patients (22.9 %) had delirium. Hypoactive was the commonest subtype (132/344 patients, 38.5 %), followed by mixed, hyperactive, and nonmotoric delirium. The prevalence was highest in Neurology (28.5 %) and Geriatrics (24.7 %), lowest in Rehabilitation (14.0 %), and intermediate in Orthopedic (20.6 %) and Internal Medicine wards (21.4 %). In a multivariable logistic regression, age (odds ratio [OR] 1.03, 95 % confidence interval [CI] 1.01-1.05), Activities of Daily Living dependence (OR 1.19, 95 % CI 1.12-1.27), dementia (OR 3.25, 95 % CI 2.41-4.38), malnutrition (OR 2.01, 95 % CI 1.29-3.14), and use of antipsychotics (OR 2.03, 95 % CI 1.45-2.82), feeding tubes (OR 2.51, 95 % CI 1.11-5.66), peripheral venous catheters (OR 1.41, 95 % CI 1.06-1.87), urinary catheters (OR 1.73, 95 % CI 1.30-2.29), and physical restraints (OR 1.84, 95 % CI 1.40-2.40) were associated with delirium. Admission to Neurology wards was also associated with delirium (OR 2.00, 95 % CI 1.29-3.14), while admission to other settings was not. Conclusions: Delirium occurred in more than one out of five patients in acute and rehabilitation hospital wards. Prevalence was highest in Neurology and lowest in Rehabilitation divisions. The "Delirium Day" project might become a useful method to assess delirium across hospital settings and a benchmarking platform for future surveys

    Local DC Distribution System in Presence of RES and Storage Devices: Multiport Converters Application

    No full text
    Modern distribution grids need to satisfy strict standards in terms of voltage quality and continuity. Furthermore, RES should be integrated at different levels in distribution systems, which can lead to non-negligible problems in terms of energy dispatch and protection systems. These considerations contributed to a new interest for direct current in distribution systems. Among different possible solutions, it may be of interest to introduce multiport converters: their centralized control allows to coordinate the various ports in order to maximize voltage quality and continuity. In this paper two types of multiport converters will be considered. For each topology power flow control will be developed to obtain consistent operation in steady state and under heavy load variation or grid connection loss and pole-to-pole fault behavior will be analyzed for the two considered topologies. Criteria to choose between the examined configurations for a specific application will be provided

    Analysis of failure rates of AC and DC micro-grids

    No full text
    Nowadays dc distribution is gaining importance, as an increasing amount of loads is natively biased in dc. In addition, dc micro-grids are usually characterized by high efficiency and simple design. Moreover, they can better accommodate renewable generation and storage systems. These are the main benefits attributed to dc distribution grids. Reliability aspects, usually, are not sufficiently taken into account. This paper describes an initial methodological approach to compare (in both analytic and numerical way) ac and dc micro-grids. In particular, the analysis has been focused on the effects on loads of main supply interruptions. The performed analysis showed that dc micro-grids have a higher immunity to these events than that displayed by ac micro-grids. On the other hand, the front-end converter (FEC) interfacing ac main supply and dc micro-grid is a single point failure for the whole system. The paper describes (and analyses) some technical solutions to reduce the effect of FEC failure on loads. Moreover, the signals and alarms that should be used in order to maximize the obtained quality-of-service levels are reported, along with some diagnostic considerations

    Multi-port converters in smart grids: Protection selectivity

    No full text
    Requests for high quality and continuity of supply have led to the study of DC micro-grids. The realization of these networks would allow exploitation of DC advantages, but it would also create fault clearance and selectivity problems because semi-conductors suffer over-currents and over-voltages. The use of traditional DC circuit breakers is often not acceptable. As an alternative, static switches can be installed to solve these problems, in spite of increases in power loss. In this work, a multi-port converter is proposed to solve the aforementioned problems. In addition, it is able to manage power flows and AC and DC I/O, improve stability, and decouple port voltages

    Wearable Services in Risk Management

    No full text
    Nuovi tessuti ore la realizzazione di abbigliamento tecnico da lavor
    corecore