145 research outputs found

    A femtosecond Raman generator for long wavelength two-photon and third harmonic generation imaging

    Get PDF
    We demonstrate a femtosecond single pass Raman generator based on an YVO crystal pumped by a high energy fiber laser at a wavelength of 1064 nm and a repetition rate of 1 MHz. The Raman generator shifts the pump wavelength to 1175 nm, in a broad band spectrum, making it suitable for multi-photon microscopy. We use the Raman generator for third harmonic generation imaging of live plant specimens as well as for two-photon fluorescence imaging of red fluorescent protein (RFP) expressing HeLa cells. We demonstrate that the photo-damage to a live specimen is low

    Ultrafast second-stokes diamond raman laser

    Get PDF
    We report a synchronously-pumped femtosecond diamond Raman laser operating with a tunable second-Stokes output. Pumped using a mode-locked Ti:sapphire laser at 840-910 nm with a duration of 165 fs, the second-Stokes wavelength was tuneable from 1082 - 1200 nm with subpicosecond duration. Our results demonstrate potential for cascaded Raman conversion to extend the wavelength coverage of standard laser sources to new regions

    Input estimation for drug discovery using optimal control and Markov chain Monte Carlo approaches

    Get PDF
    Input estimation is employed in cases where it is desirable to recover the form of an input function which cannot be directly observed and for which there is no model for the generating process. In pharmacokinetic and pharmacodynamic modelling, input estimation in linear systems (deconvolution) is well established, while the nonlinear case is largely unexplored. In this paper, a rigorous definition of the input-estimation problem is given, and the choices involved in terms of modelling assumptions and estimation algorithms are discussed. In particular, the paper covers Maximum a Posteriori estimates using techniques from optimal control theory, and full Bayesian estimation using Markov Chain Monte Carlo (MCMC) approaches. These techniques are implemented using the optimisation software CasADi, and applied to two example problems: one where the oral absorption rate and bioavailability of the drug eflornithine are estimated using pharmacokinetic data from rats, and one where energy intake is estimated from body-mass measurements of mice exposed to monoclonal antibodies targeting the fibroblast growth factor receptor (FGFR) 1c. The results from the analysis are used to highlight the strengths and weaknesses of the methods used when applied to sparsely sampled data. The presented methods for optimal control are fast and robust, and can be recommended for use in drug discovery. The MCMC-based methods can have long running times and require more expertise from the user. The rigorous definition together with the illustrative examples and suggestions for software serve as a highly promising starting point for application of input-estimation methods to problems in drug discovery

    Input estimation for extended-release formulations exemplified with exenatide

    Get PDF
    Estimating the in vivo absorption profile of a drug is essential when developing extended-release medications. Such estimates can be obtained by measuring plasma concentrations over time and inferring the absorption from a model of the drug’s pharmacokinetics. Of particular interest is to predict the bioavailability—the fraction of the drug that is absorbed and enters the systemic circulation. This paper presents a framework for addressing this class of estimation problems and gives advice on the choice of method. In parametric methods, a model is constructed for the absorption process, which can be difficult when the absorption has a complicated profile. Here, we place emphasis on non-parametric methods that avoid making strong assumptions about the absorption. A modern estimation method that can address very general input-estimation problems has previously been presented. In this method, the absorption profile is modeled as a stochastic process, which is estimated using Markov chain Monte Carlo techniques. The applicability of this method for extended-release formulation development is evaluated by analyzing a dataset of Bydureon, an injectable extended-release suspension formulation of exenatide, a GLP-1 receptor agonist for treating diabetes. This drug is known to have non-linear pharmacokinetics. Its plasma concentration profile exhibits multiple peaks, something that can make parametric modeling challenging, but poses no major difficulties for non-parametric methods. The method is also validated on synthetic data, exploring the effects of sampling and noise on the accuracy of the estimates

    Widefield two-photon excitation without scanning : live cell microscopy with high time resolution and low photo-bleaching

    Get PDF
    We demonstrate fluorescence imaging by two-photon excitation without scanning in biological specimens as previously described by Hwang and co-workers, but with an increased field size and with framing rates of up to 100 Hz. During recordings of synaptically-driven Ca2+ events in primary rat hippocampal neurone cultures loaded with the fluorescent Ca2+ indicator Fluo-4 AM, we have observed greatly reduced photo-bleaching in comparison with single-photon excitation. This method, which requires no costly additions to the microscope, promises to be useful for work where high time-resolution is required

    Diversity and Distribution of Mites (Acari: Ixodida, Mesostigmata, Trombidiformes, Sarcoptiformes) in the Svalbard Archipelago

    Get PDF
    Svalbard is a singular region to study biodiversity. Located at a high latitude and geographically isolated, the archipelago possesses widely varying environmental conditions and unique flora and fauna communities. It is also here where particularly rapid environmental changes are occurring, having amongst the fastest increases in mean air temperature in the Arctic. One of the most common and species-rich invertebrate groups in Svalbard is the mites (Acari). We here describe the characteristics of the Svalbard acarofauna, and, as a baseline, an updated inventory of 178 species (one Ixodida, 36 Mesostigmata, 43 Trombidiformes, and 98 Sarcoptiformes) along with their occurrences. In contrast to the Trombidiformes and Sarcoptiformes, which are dominated in Svalbard by species with wide geographical distributions, the Mesostigmata include many Arctic species (39%); it would thus be an interesting future study to determine if mesostigmatid communities are more affected by global warming then other mite groups. A large number of new species (42 spp.) have been described from Svalbard, including 15 that have so far been found exclusively there. It is yet uncertain if any of these latter species are endemic: six are recent findings, the others are old records and, in most cases, impossible to verify. That the Arctic is still insufficiently sampled also limits conclusions concerning endemicity.publishedVersio

    Reporting nuclear cardiology: a joint position paper by the European Association of Nuclear Medicine (EANM) and the European Association of Cardiovascular Imaging (EACVI)

    Get PDF
    The report of an imaging procedure is a critical component of an examination, being the final and often the only communication from the interpreting physician to the referring or treating physician. Very limited evidence and few recommendations or guidelines on reporting imaging studies are available; therefore, an European position statement on how to report nuclear cardiology might be useful. The current paper combines the limited existing evidence with expert consensus, previously published recommendations as well as current clinical practices. For all the applications discussed in this paper (myocardial perfusion, viability, innervation, and function as acquired by single photon emission computed tomography and positron emission tomography or hybrid imaging), headings cover laboratory and patient demographics, clinical indication, tracer administration and image acquisition, findings, and conclusion of the report. The statement also discusses recommended terminology in nuclear cardiology, image display, and preliminary reports. It is hoped that this statement may lead to more attention to create well-written and standardized nuclear cardiology reports and eventually lead to improved clinical outcom
    • 

    corecore