71 research outputs found

    Technical note: Introduction of a superconducting gravimeter as novel hydrological sensor for the Alpine research catchment Zugspitze

    Get PDF
    GFZ (German Research Centre for Geosciences) set up the Zugspitze Geodynamic Observatory Germany with a worldwide unique installation of a superconducting gravimeter at the summit of Mount Zugspitze on top of the Partnach spring catchment. This high alpine catchment is well instrumented, acts as natural lysimeter and has significant importance for water supply to its forelands, with a large mean annual precipitation of 2080ĝ€¯mm and a long seasonal snow cover period of 9 months, while showing a high sensitivity to climate change. However, regarding the majority of alpine regions worldwide, there is only limited knowledge on temporal water storage variations due to sparsely distributed hydrological and meteorological sensors and the large variability and complexity of signals in alpine terrain. This underlines the importance of well-equipped areas such as Mount Zugspitze serving as natural test laboratories for improved monitoring, understanding and prediction of alpine hydrological processes. The observatory superconducting gravimeter, OSG 052, supplements the existing sensor network as a novel hydrological sensor system for the direct observation of the integral gravity effect of total water storage variations in the alpine research catchment at Zugspitze. Besides the experimental set-up and the available data sets, the gravimetric methods and gravity residuals are presented based on the first 27 months of observations from 29 December 2018 to 31 March 2021. The snowpack is identified as being a primary contributor to seasonal water storage variations and, thus, to the gravity residuals with a signal range of up to 750ĝ€¯nms-2 corresponding to 1957ĝ€¯mm snow water equivalent measured with a snow scale at an altitude of 2420ĝ€¯m at the end of May 2019. Hydro-gravimetric sensitivity analysis reveal a snow-gravimetric footprint of up to 4ĝ€¯km distance around the gravimeter, with a dominant gravity contribution from the snowpack in the Partnach spring catchment. This shows that the hydro-gravimetric approach delivers representative integral insights into the water balance of this high alpine site. © Copyright

    Comparison between two mobile absolute gravimeters: optical versus atomic interferometers

    Full text link
    We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universit\"at of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 {\mu}Gal

    Application of Luminex Gastrointestinal Pathogen Panel to human stool samples from Côte d'Ivoire

    Get PDF
    Gastrointestinal infections caused by viruses, bacteria, and parasites are endemic in most developing countries due to inadequate provision of safe water supplies, sanitation, and hygiene. To investigate the enteric pathogens infecting people living in Côte d'Ivoire, the Luminex Gastrointestinal Pathogen Panel (xTAG GPP) assay was used to analyze 34 human fecal samples. This study represents the first application of this technology to samples from a sub-Saharan African country

    Self-attraction effect and correction on three absolute gravimeters

    Full text link
    The perturbations of the gravitational field due to the mass distribution of an absolute gravimeter have been studied. The so called Self Attraction Effect (SAE) is crucial for the measurement accuracy, especially for the International Comparisons, and for the uncertainty budget evaluation. Three instruments have been analysed: MPG-2, FG5-238 and IMPG-02. The SAE has been calculated using a numerical method based on FEM simulation. The observed effect has been treated as an additional vertical gravity gradient. The correction (SAC) to be applied to the computed g value has been associated with the specific height level, where the measurement result is typically reported. The magnitude of the obtained corrections is of order 1E-8 m/s2.Comment: 14 pages, 8 figures, submitted to Metrologi

    Role of blood pressure in mediating carotid artery dilation in response to sympathetic stimulation in healthy, middle-aged individuals

    Get PDF
    Objectives: Carotid artery diameter responses to sympathetic stimulation, i.e., carotid artery reactivity (CAR), represent a novel test of vascular health and relates to cardiovascular disease (CVD)/risk. This study aims to understand the relationship between the increase in blood pressure and carotid artery diameter response during the CAR-test in healthy, middle-aged men. Methods: Sample consisted of 40 normotensive men (aged 31–59 years) with no history of CVD of currently taking medication. Noninvasive ultrasound was used to measure carotid artery diameter during the cold pressor test (CPT), with CAR% being calculated as the relative change from baseline (%). Mean arterial pressure (MAP) was measured with beat-to-beat blood pressure recording. Results: CAR% was 4.4 ± 5.4%, peaking at 92 ± 43 seconds. MAP increased from 88 ± 9 mmHg to 110 ± 15 mmHg, peaked at 112 ± 38 seconds, which was significantly later than the diameter peak (P = 0.04). The correlation between resting MAP and CAR% was weak (r = 0.209 P = 0.197). Tertiles based on resting MAP or MAP-increase revealed no significant differences between groups in subject characteristics including age, body mass index, or CAR% (all P > 0.05). Subgroup analysis of individuals with carotid constriction (n = 6) vs. dilation (n = 34), revealed no significant difference in resting MAP or increase in MAP (P = 0.209 and 0.272, respectively). Conclusion: Our data suggest that the characteristic increase in MAP during the CPT does not mediate carotid artery vasomotion

    Final report of EURAMET.M.G-K3 regional comparison of absolute gravimeters

    Get PDF
    The regional key comparison of absolute gravimeters, EURAMET.M.G-K3 and the simultaneously organized additional comparison, was held in Germany at the Geodetic Observatory Wettzell of the German Federal Agency for Cartography and Geodesy in the spring of 2018.Here we present the list of the participants who actually performed measurements during the comparison, the data submitted by the operators as well as the results of the determination of the gravity as a function of height at the comparison sites. The measurement strategy is briefly discussed and the results of the data harmonization is documented. Finally, the results of the constrained least squares adjustment are presented including the degrees of equivalence of each gravimeter and the key comparison reference values.Main textTo reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).Export citation and abstract BibTeX RIS

    Geodesy and metrology with a transportable optical clock

    Get PDF
    partially_open24openGrotti, Jacopo; Koller, Silvio; Vogt, Stefan; Häfner, Sebastian; Sterr, Uwe; Lisdat, Christian; Denker, Heiner; Voigt, Christian; Timmen, Ludger; Rolland, Antoine; Baynes, Fred N.; Margolis, Helen S.; Zampaolo, Michel; Thoumany, Pierre; Pizzocaro, Marco; Rauf, Benjamin; Bregolin, Filippo; Tampellini, Anna; Barbieri, Piero; Zucco, Massimo; Costanzo, Giovanni A.; Clivati, Cecilia; Levi, Filippo; Calonico, DavideGrotti, Jacopo; Koller, Silvio; Vogt, Stefan; Häfner, Sebastian; Sterr, Uwe; Lisdat, Christian; Denker, Heiner; Voigt, Christian; Timmen, Ludger; Rolland, Antoine; Baynes, Fred N.; Margolis, Helen S.; Zampaolo, Michel; Thoumany, Pierre; Pizzocaro, Marco; Rauf, Benjamin; Bregolin, Filippo; Tampellini, Anna; Barbieri, Piero; Zucco, Massimo; Costanzo, Giovanni A.; Clivati, Cecilia; Levi, Filippo; Calonico, David

    Altered mRNA expression of genes related to nerve cell activity in the fracture callus of older rats: A randomized, controlled, microarray study

    Get PDF
    BACKGROUND: The time required for radiographic union following femoral fracture increases with age in both humans and rats for unknown reasons. Since abnormalities in fracture innervation will slow skeletal healing, we explored whether abnormal mRNA expression of genes related to nerve cell activity in the older rats was associated with the slowing of skeletal repair. METHODS: Simple, transverse, mid-shaft, femoral fractures with intramedullary rod fixation were induced in anaesthetized female Sprague-Dawley rats at 6, 26, and 52 weeks of age. At 0, 0.4, 1, 2, 4, and 6 weeks after fracture, a bony segment, one-third the length of the femur, centered on the fracture site, including the external callus, cortical bone, and marrow elements, was harvested. cRNA was prepared and hybridized to 54 Affymetrix U34A microarrays (3/age/time point). RESULTS: The mRNA levels of 62 genes related to neural function were affected by fracture. Of the total, 38 genes were altered by fracture to a similar extent at the three ages. In contrast, eight neural genes showed prolonged down-regulation in the older rats compared to the more rapid return to pre-fracture levels in younger rats. Seven genes were up-regulated by fracture more in the younger rats than in the older rats, while nine genes were up-regulated more in the older rats than in the younger. CONCLUSIONS: mRNA of 24 nerve-related genes responded differently to fracture in older rats compared to young rats. This differential expression may reflect altered cell function at the fracture site that may be causally related to the slowing of fracture healing with age or may be an effect of the delayed healing

    Regional comparison of absolute gravimeters, EURAMET.M.G-K2 key comparison

    Get PDF
    In the framework of the regional EURAMET.M.G-K2 comparison of absolute gravimeters, 17 gravimeters were compared in November 2015. Four gravimeters were from different NMIs and DIs, they were used to link the regional comparison to the CCM.G.K2 by means of linking converter. Combined least-squares adjustments with weighted constraint was used to determine KCRV. Several pilot solutions are presented and compared with the official solution to demonstrate influences of different approaches (e.g. definition of weights and the constraint) on results of the adjustment. In case of the official solution, all the gravimeters are in equivalence with declared uncertainties. == Main text To reach the main text of this paper, click on Final Report [http://www.bipm.org/utils/common/pdf/final_reports/M/G-K2/EURAMET.M.G-K2.pdf] . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ [http://kcdb.bipm.org/] . The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA)
    corecore