    Correction of patient positioning errors based on in-line cone beam CTs: clinical implementation and first experiences

    Get PDF
    BACKGROUND: The purpose of the study was the clinical implementation of a kV cone beam CT (CBCT) for setup correction in radiotherapy. PATIENTS AND METHODS: For evaluation of the setup correction workflow, six tumor patients (lung cancer, sacral chordoma, head-and-neck and paraspinal tumor, and two prostate cancer patients) were selected. All patients were treated with fractionated stereotactic radiotherapy, five of them with intensity modulated radiotherapy (IMRT). For patient fixation, a scotch cast body frame or a vacuum pillow, each in combination with a scotch cast head mask, were used. The imaging equipment, consisting of an x-ray tube and a flat panel imager (FPI), was attached to a Siemens linear accelerator according to the in-line approach, i.e. with the imaging beam mounted opposite to the treatment beam sharing the same isocenter. For dose delivery, the treatment beam has to traverse the FPI which is mounted in the accessory tray below the multi-leaf collimator. For each patient, a predefined number of imaging projections over a range of at least 200 degrees were acquired. The fast reconstruction of the 3D-CBCT dataset was done with an implementation of the Feldkamp-David-Kress (FDK) algorithm. For the registration of the treatment planning CT with the acquired CBCT, an automatic mutual information matcher and manual matching was used. RESULTS AND DISCUSSION: Bony landmarks were easily detected and the table shifts for correction of setup deviations could be automatically calculated in all cases. The image quality was sufficient for a visual comparison of the desired target point with the isocenter visible on the CBCT. Soft tissue contrast was problematic for the prostate of an obese patient, but good in the lung tumor case. The detected maximum setup deviation was 3 mm for patients fixated with the body frame, and 6 mm for patients positioned in the vacuum pillow. Using an action level of 2 mm translational error, a target point correction was carried out in 4 cases. The additional workload of the described workflow compared to a normal treatment fraction led to an extra time of about 10–12 minutes, which can be further reduced by streamlining the different steps. CONCLUSION: The cone beam CT attached to a LINAC allows the acquisition of a CT scan of the patient in treatment position directly before treatment. Its image quality is sufficient for determining target point correction vectors. With the presented workflow, a target point correction within a clinically reasonable time frame is possible. This increases the treatment precision, and potentially the complex patient fixation techniques will become dispensable

    A systematic review of methods to immobilise breast tissue during adjuvant breast irradiation

    Get PDF
    Greater use of 3D conformal, Intensity Modulated Radiotherapy (IMRT) and external beam partial breast irradiation following local excision (LE) for breast cancer has necessitated a review of the effectiveness of immobilisation methods to stabilise breast tissue. To identify the suitability of currently available breast (rather than thorax) immobilisation techniques an appraisal of the literature was undertaken. The aim was to identify and evaluate the benefit of additional or novel immobilisation approaches (beyond the standard supine, single arm abducted and angled breast board technique adopted in most radiotherapy departments). A database search was supplemented with an individual search of key radiotherapy peer-reviewed journals, author searching, and searching of the grey literature. A total of 27 articles met the inclusion criteria. The review identified good reproducibility of the thorax using the standard supine arm-pole technique. Reproducibility with the prone technique appears inferior to supine methods (based on data from existing randomised controlled trials). Assessing the effectiveness of additional breast support devices (such as rings or thermoplastic material) is hampered by small sample sizes and a lack of randomised data for comparison. Attention to breast immobilisation is recommended, as well as agreement on how breast stability should be measured using volumetric imaging. Keywords: Breast, immobilisation, positioning, reproducibility, review.</p

    Measurement of the Omega_c Lifetime

    Full text link
    We present the measurement of the lifetime of the Omega_c we have performed using three independent data samples from two different decay modes. Using a Sigma- beam of 340 GeV/c we have obtained clean signals for the Omega_c decaying into Xi- K- pi+ pi+ and Omega- pi+ pi- pi+, avoiding topological cuts normally used in charm analysis. The short but measurable lifetime of the Omega_c is demonstrated by a clear enhancement of the signals at short but finite decay lengths. Using a continuous maximum likelihood method we determined the lifetime to be tau(Omega_c) = 55 +13-11(stat) +18-23(syst) fs. This makes the Omega_c the shortest living weakly decaying particle observed so far. The short value of the lifetime confirms the predicted pattern of the charmed baryon lifetimes and demonstrates that the strong interaction plays a vital role in the lifetimes of charmed hadrons.Comment: 15 pages, including 7 figures; gzipped, uuencoded postscrip

    Search for the exotic Ξ(1860)\Xi^{--}(1860) Resonance in 340GeV/c Σ\Sigma^--Nucleus Interactions

    Full text link
    We report on a high statistics search for the Ξ(1860)\Xi^{--}(1860) resonance in Σ\Sigma^--nucleus collisions at 340GeV/c. No evidence for this resonance is found in our data sample which contains 676000 Ξ\Xi^- candidates above background. For the decay channel Ξ(1860)Ξπ\Xi^{--}(1860) \to \Xi^-\pi^- and the kinematic range 0.15<xF<<x_F<0.9 we find a 3σ\sigma upper limit for the production cross section of 3.1 and 3.5 μ\mub per nucleon for reactions with carbon and copper, respectively.Comment: 5 pages, 4 figures, modification of ref. 43 and 4

    Inverse planned stereotactic intensity modulated radiotherapy (IMRT) in the treatment of incompletely and completely resected adenoid cystic carcinomas of the head and neck: initial clinical results and toxicity of treatment

    Get PDF
    BACKGROUND: Presenting the initial clinical results in the treatment of complex shaped adenoid cystic carcinomas (ACC) of the head and neck region by inverse planned stereotactic IMRT. MATERIALS: 25 patients with huge ACC in different areas of the head and neck were treated. At the time of radiotherapy two patients already suffered from distant metastases. A complete resection of the tumor was possible in only 4 patients. The remaining patients were incompletely resected (R2: 20; R1: 1). 21 patients received an integrated boost IMRT (IBRT), which allow the use of different single doses for different target volumes in one fraction. All patients were treated after inverse treatment planning and stereotactic target point localization. RESULTS: The mean folllow-up was 22.8 months (91 – 1490 days). According to Kaplan Meier the three year overall survival rate was 72%. 4 patients died caused by a systemic progression of the disease. The three-year recurrence free survival was according to Kaplan Meier in this group of patients 38%. 3 patients developed an in-field recurrence and 3 patient showed a metastasis in an adjacent lymph node of the head and neck region. One patient with an in-field recurrence and a patient with the lymph node recurrence could be re-treated by radiotherapy. Both patients are now controlled. Acute side effects >Grade II did only appear so far in a small number of patients. CONCLUSION: The inverse planned stereotactic IMRT is feasible in the treatment of ACC. By using IMRT, high control rates and low side effects could by achieved. Further evaluation concerning the long term follow-up is needed. Due to the technical advantage of IMRT this treatment modality should be used if a particle therapy is not available