15 research outputs found

    Detection of vascular morphology by high frequency intravascular ultrasonic imaging

    Get PDF
    This study was designed to validate the potential clinical utility of intravascular ultrasonic imaging in vitro and in vivo. In vitro studies were performed to assess the accuracy of dimensional and morphological information. In vitro images of human vessels (n = 75) demonstrated that lesion thickness determined echographically closely related with histological samples (r = 0.83). Morphologically, muscular and elastic arteries could be distinguished echographically based on the echogenicity of the arterial media. Close relation was also found in the morphological subtypes of atherosclerosis. Subsequently, intravascular ultrasound was used percutaneously in vivo in 20 patients to obtain images of the iliac and superficial femoral artery. High quality real-time images were obtained. Normal vessels were seen showing pulsatile circular images with a hypoechoic muscular media resulting in a typical three-layered appearance. Diseased arteries revealed non-obstructive and obstructive lumen. At the site of obstruction thinning of the muscular media was evident. Pulsation was not always present. Following dilatation of the obstructive lesion using balloon angioplasty the ultrasonic cross-sections changed drastically revealing plaque rupture, dissection, plaque-free wall rupture, rest stenosis and oedema. We conclude that intravascular ultrasonic imaging is a promising technique to document accurate dimensional and morphological characteristics of human vascular disease for guidance of therapeutic interventions

    Femorodistal venous bypass evaluated with intravascular ultrasound

    Get PDF
    Objective:To evaluate the feasibility of intravascular ultrasound imaging during femorodistal venous bypass procedures to assess qualitative and quantitative parameters of the greater saphenous vein and to detect potential causes for (re)stenosis and/or occlusion.Methods:Intravascular ultrasound data obtained from 15 patients were reviewed and compared with angiographic data.Results:Intravascular ultrasound enabled differentiation between normal and thickened vein wall. Venous side-branches could be located. Intact valves could be differentiated from valves disrupted by valve cutting. Patent anastomoses could be distinguished from anastomoses with some degree of obstruction. Intravascular ultrasound imaging of the inflow and outflow tracts revealed obstructive lesions, not evidenced angiographically. Quantitative analysis revealed that the median normal vein wall thickness (tunica intima and tunica media) was 0.25 mm (range 0.17–0.40 mm). The distinct vein wall thickening encountered in three patients measured 0.82, 0.95 and 1.06 mm, respectively, and was associated with narrowing in two patients. In five of 15 patients intravascular ultrasound findings altered surgical management.Conclusion:Intravascular ultrasound is able to assess qualitative and quantitative parameters of the venous bypass and has the potential to influence surgical management based on morphologic and quantitative data

    Temporal averaging for quantification of lumen dimensions in intravascular ultrasound images

    Get PDF
    Quantitative analysis of arterial dimensions from high frequency intravascular ultrasound images (30 MHz) may be hampered by strong blood scattering. Replacement of blood by saline is one method to provide a clear view of the arterial lumen; another method is that of temporal averaging of successive ultrasound images. The accuracy of this latter method was tested by comparing the lumen area measurements on the temporal-averaged image, with the data of the same cross-section obtained from the single-frame and saline-filled images. The mean lumen area measured on the temporal-averaged images was similar to that measured on the single-frame images (mean difference: −0.02 ± 1.16 mm2; p = ns). The mean lumen a

    Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty

    Get PDF
    Objective:This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery.Materials:Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 39 patients before and after PTA were analysed.Results:Angiographically the diameter of the remaining stenosis seen after PTA was classified as < 50% in 31 patients (success); in eight patients a failure was encountered. Evaluating at 6 months the functional and anatomic results of the PTA in 31 patients, the intervention was a success in 14 patients (Group I) and a failure in 17 patients (Group II). The remaining eight patients defined as angiographic failure following PTA comprised Group III. Neither qualitative nor quantitative IVUS data obtained before PTA could predict outcome. Conversely, after PTA, the extent of dissection was significantly more severe in Groups II and III than in Group I. Similarly, significant differences were found between Groups I and II for mean free lumen area (13.2 vs. 9.7 mm2, respectively) and mean free lumen diameter (4.1 vs. 3.5 mm, respectively). Quantitative data obtained in Group II were similar to those in Group III.Conclusion:This preliminary study demonstrates that following PTA the extent of dissection, free lumen area and diameter seen with IVUS are predictive factors of patency. Future studies with more patients are mandatory to further highlight the sensitivity of these observations

    Validation of quantitative analysis of intravascular ultrasound images

    Get PDF
    This study investigated the accuracy and reproducibility of a computer-aided method for quantification of intravascular ultrasound. The computer analysis system was developed on an IBM compatible PC/AT equipped with a framegrabber. The quantitative assessment of lumen area, lesion area and percent area obstruction was performed by tracing the boundaries of the free lumen and original lumen. Accuracy of the analysis system was tested in a phantom study. Echographic measurements of lumen and lesion area derived from 16 arterial specimens were compared with data obtained by histology. The differences in lesion area measurements between histology and ultrasound were minimal (mean ± SD: -0.27±1.79 mm2, p>0.05). Lumen area measurements from histology were significantly smaller than those with ultrasound due to mechanical deformation of histologic specimens (-5.38±5.09 mm2, p0.05). Finally, intra- and interobserver variability of our quantitative method was evaluated in measurements of 100 in vivo ultrasound images. The results showed that variations in lumen area measurements were low (5%) whereas variations in lesion area and percent area obstruction were relatively high (13%, 10%, respectively). Results of this study indicate that our quantitative method provides accurate and reproducible measurements of lumen and lesion area. Thus, intravascular ultrasound can be used for clinical investigation, including assessment of vascular stenosis and evaluation of therapeutic intervention

    Evolution of renal function and predictive value of serial renal assessments among patients with acute coronary syndrome: BIOMArCS study

    Get PDF
    Background: Impaired renal function predicts mortality in acute coronary syndrome (ACS), but its evolution immediately following index ACS and preceding next ACS has not been described in detail. We aimed to describe this evolution using serial measurements of creatinine, glomerular filtration rate [eGFRCr] and cystatin C [CysC]. Methods: F

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362
    corecore