172 research outputs found

    CVD-based techniques for the synthesis of nanographites and nanodiamonds

    Get PDF
    We report about some Chemical Vapor Deposition approaches used to produce a variety of C-sp2 and C-sp3 crystalline nanostructures. The methodologies developed in our laboratories provide custom-made solutions for the fabrication of specific carbon nanomaterials with properties tailored for applications in the field of nanotechnology

    Macroscopic self standing SWCNT fibers as efficient electron emitters with very high emission current for robust cold cathodes

    Get PDF
    A novel of self-standing nanotube-based cold cathode is described. The electron emitter is a single macroscopic fibre spun from neat single wall carbon nanotubes and consists of an ensemble of nanotube bundles held together by van der Waals forces. Field emission measurements carried out using two different types of apparatus demonstrated the long working life of the realised cathode. The system is able to emit at very high current densities, up to 13 A/cm2, and shows very low values of both turn on and threshold field, 0.12 V/lm and 0.21 V/lm, respectively. Such easy to handle self-standing electron sources assure good performances and represent an enabling technology for a scalable production of cold cathodes. 2012 Elsevier Ltd. All rights reserved. 1. Introduction Due to a unique combination of properties, including high electrical and thermal conductivity, and high mechanical/ chemical/thermal stability, carbon nanotubes (CNTs) have been recognised as ideal candidate materials for application in microelectronics [1]. Moreover, the high aspect ratio characterising this intriguing material makes possible to significantly strengthen electric fields into the vicinity of nanotubes tips

    Photonuclear reactions of actinides in the giant dipole resonance region

    Full text link
    Photonuclear reactions at energies covering the giant dipole resonance (GDR) region are analyzed with an approach based on nuclear photoabsorption followed by the process of competition between light particle evaporation and fission for the excited nucleus. The photoabsorption cross section at energies covering the GDR region is contributed by both the Lorentz type GDR cross section and the quasideuteron cross section. The evaporation-fission process of the compound nucleus is simulated in a Monte-Carlo framework. Photofission reaction cross sections are analyzed in a systematic manner in the energy range of \sim 10-20 MeV for the actinides 232^{232}Th, 238^{238}U and 237^{237}Np. Photonuclear cross sections for the medium-mass nuclei 63^{63}Cu and 64^{64}Zn, for which there are no fission events, are also presented. The study reproduces satisfactorily the available experimental data of photofission cross sections at GDR energy region and the increasing trend of nuclear fissility with the fissility parameter Z2/AZ^2/A for the actinides.Comment: 4 pages including 2 tables and 1 figur

    Measurement of lipocalin-2 and syndecan-4 levels to differentiate bacterial from viral infection in children with community-acquired pneumonia

    Get PDF
    BACKGROUND: In this study, we evaluated the lipocalin-2 (LIP2) and syndecan-4 (SYN4) levels in children who were hospitalized for radiologically confirmed CAP in order to differentiate bacterial from viral infection. The results regarding the LIP2 and SYN4 diagnostic outcomes were compared with the white blood cell (WBC) count and C reactive protein (CRP) levels. METHODS: A total of 110 children <14 years old who were hospitalized for radiologically confirmed CAP were enrolled. Serum samples were obtained upon admission and on day 5 to measure the levels of LIP2, SYN4, and CRP as well as the WBC. Polymerase chain reaction of the respiratory secretions and tests on blood samples were performed to detect respiratory viruses, Streptococcus pneumoniae, and Mycoplasma pneumoniae. RESULTS: CAP was considered to be due to a probable bacterial infection in 74 children (67.3 %) and due to a probable viral infection in 16 children (14.5 %). Overall, 84 children (76.4 %) were diagnosed with severe CAP. The mean values of the WBC count and the LIP2 and SYN4 levels did not differ among the probable bacterial, probable viral, and undetermined cases. However, the CRP serum concentrations were significantly higher in children with probable bacterial CAP than in those with probable viral disease (32.2\u2009\ub1\u200955.5 mg/L vs 9.4\u2009\ub1\u200917.0 mg/L, p\u2009<\u20090.05). The WBC count was the best predictor of severe CAP, but the differences among the studied variables were marginal. The WBC count was significantly lower on day 5 in children with probable bacterial CAP (p\u2009<\u20090.01) and in those with an undetermined etiology (p\u2009<\u20090.01). The CRP and LIP2 levels were significantly lower 5 days after enrollment in all of the studied groups, independent of the supposed etiology of CAP (p\u2009<\u20090.01 for all comparisons). No statistically significant variation was observed for SYN4. CONCLUSIONS: Measuring the LIP2 and SYN4 levels does not appear to solve the problem of the poor reliability of routine laboratory tests in defining the etiology and severity of pediatric CAP. Currently, the CRP levels and WBC, when combined with evaluation of clinical data, can be used to limit the overuse of antibiotics as much as possible and to provide the best treatment to the patient

    Search for composite and exotic fermions at LEP 2

    Get PDF
    A search for unstable heavy fermions with the DELPHI detector at LEP is reported. Sequential and non-canonical leptons, as well as excited leptons and quarks, are considered. The data analysed correspond to an integrated luminosity of about 48 pb^{-1} at an e^+e^- centre-of-mass energy of 183 GeV and about 20 pb^{-1} equally shared between the centre-of-mass energies of 172 GeV and 161 GeV. The search for pair-produced new leptons establishes 95% confidence level mass limits in the region between 70 GeV/c^2 and 90 GeV/c^2, depending on the channel. The search for singly produced excited leptons and quarks establishes upper limits on the ratio of the coupling of the excited fermio

    Search for lightest neutralino and stau pair production in light gravitino scenarios with stau NLSP

    Get PDF
    Promptly decaying lightest neutralinos and long-lived staus are searched for in the context of light gravitino scenarios. It is assumed that the stau is the next to lightest supersymmetric particle (NLSP) and that the lightest neutralino is the next to NLSP (NNLSP). Data collected with the Delphi detector at centre-of-mass energies from 161 to 183 \GeV are analysed. No evidence of the production of these particles is found. Hence, lower mass limits for both kinds of particles are set at 95% C.L.. The mass of gaugino-like neutralinos is found to be greater than 71.5 GeV/c^2. In the search for long-lived stau, masses less than 70.0 to 77.5 \GeVcc are excluded for gravitino masses from 10 to 150 \eVcc . Combining this search with the searches for stable heavy leptons and Minimal Supersymmetric Standard Model staus a lower limit of 68.5 \GeVcc may be set for the stau mas

    Results from the CUORE-0 experiment

    Get PDF
    The CUORE-0 experiment searched for neutrinoless double beta decay in 130Te using an array of 52 tellurium dioxide crystals, operated as bolometers at a temperature of 10 mK. It took data in the Gran Sasso National Laboratory (Italy) since March 2013 to March 2015. We present the results of a search for neutrinoless double beta decay in 9.8 kg-years 130Te exposure that allowed us to set the most stringent limit to date on this half-life. The performance of the detector in terms of background and energy resolution is also reported

    Low energy analysis techniques for CUORE

    Get PDF
    CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of 130Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0
    corecore