930 research outputs found

    Dissipative bracing-based seismic retrofit hypothesis of an elevated water storage tank with R/C frame staging structure

    Get PDF
    A seismic performance assessment and supplemental damping-based retrofit study on a heritage reinforced concrete (R/C) elevated water storage tank is presented. The structure was built in the early 1930s as water supplier for the coal power plant of Santa Maria Novella Station in Florence, and is still in service. The tank has a R/C frame supporting structure and is currently used as water supplier for trains and platform services. The dynamic behavior of the fluid is simulated by a classical convective plus impulsive mass model, for which a discrete three-dimensional schematization is originally implemented in the finite element analysis. The time-history assessment enquiry highlights a remarkable plastic response of the frame structure under seismic action scaled at the maximum considered earthquake level. Based on these results, a retrofit hypothesis is proposed, consisting in the installation in the staging structure of a dissipative bracing (DB) system incorporating pressurized fluid viscous spring-dampers. The DB technology, studied by the first two authors during the last two decades by focusing on the numerical and analytical modeling, the experimental characterization and verification, the definition of design procedures, and the development of several applications to R/C and steel frame building structures, is explored for the first time within the study reported here for the seismic retrofit of elevated tanks. The mechanical parameters, design criteria and technical implementation details of the rehabilitation strategy are illustrated. The verification time-history analyses in protected conditions show that a substantial enhancement of the seismic response capacities of the structure is attained as compared to its original configuration, with little architectural intrusion, quick installation works and low costs

    Planck Low Frequency Instrument: Beam Patterns

    Full text link
    The Low Frequency Instrument on board the ESA Planck satellite is coupled to the Planck 1.5 meter off-axis dual reflector telescope by an array of 27 corrugated feed horns operating at 30, 44, 70, and 100 GHz. We briefly present here a detailed study of the optical interface devoted to optimize the angular resolution (10 arcmin at 100 GHz as a goal) and at the same time to minimize all the systematics coming from the sidelobes of the radiation pattern. Through optical simulations, we provide shapes, locations on the sky, angular resolutions, and polarization properties of each beam.Comment: On behalf of the Planck collaboration. 3 pages, 1 figure. Article published in the Proceedings of the 2K1BC Experimental Cosmology at millimetre wavelength

    Capillary Flow-MRI:Quantifying Micron-Scale Cooperativity in Complex Dispersions

    Get PDF
    Strongly confined flow of particulate fluids is encountered in applications ranging from three-dimensional (3D) printing to the spreading of foods and cosmetics into thin layers. When flowing in constrictions with gap sizes, w, within 102 times the mean size of particles or aggregates, d, structured fluids experience enhanced bulk velocities and inhomogeneous viscosities, as a result of so-called cooperative, or nonlocal, particle interactions. Correctly predicting cooperative flow for a wide range of complex fluids requires high-resolution flow imaging modalities applicable in situ to even optically opaque fluids. To this goal, we here developed a pressure-driven high-field magnetic resonance imaging (MRI) velocimetry platform, comprising a pressure controller connected to a capillary. Wall properties and diameter could be modified respectively as hydrophobic/hydrophilic, or within w ∼ 100-540 μm. By achieving a high spatial resolution of 9 μm, flow cooperativity length scales, ξ, down to 15 μm in Carbopol with d ∼ 2 μm could be quantified by means of established physical models with an accuracy of 13%. The same approach was adopted for a heterogeneous fat crystal dispersion (FCD) with d and ξ values up to an order of magnitude higher than those for Carbopol. We found that for strongly confined flow of Carbopol in the 100 μm capillary, ξ is independent of flow conditions. For the FCD, ξ increases with gap size and applied pressures over 0.25-1 bar. In both samples, nonlocal interactions span domains up to about 5-8 particles but, at the highest confinement degree explored, ∼8% for FCD, domains of only ∼2 particles contribute to cooperative flow. The developed flow-MRI platform is easily scalable to ultrahigh field MRI conditions for chemically resolved velocimetric measurements of, e.g., complex fluids with anisotropic particles undergoing alignment. Future potential applications of the platform encompass imaging extrusion under confinement during the 3D printing of complex dispersions or in in vitro vascular and perfusion studies.</p

    Forever Young: Structural Stability of Telomeric Guanine Quadruplexes in the Presence of Oxidative DNA Lesions**

    Get PDF
    Human telomeric DNA, in G-quadruplex (G4) conformation, is characterized by a remarkable structural stability that confers it the capacity to resist to oxidative stress producing one or even clustered 8-oxoguanine (8oxoG) lesions. We present a combined experimental/computational investigation, by using circular dichroism in aqueous solutions, cellular immunofluorescence assays and molecular dynamics simulations, that identifies the crucial role of the stability of G4s to oxidative lesions, related also to their biological role as inhibitors of telomerase, an enzyme overexpressed in most cancers associated to oxidative stress

    Magnetic field hourly averages from the Rome-GSFC experiment aboard Helios 1 and Helio 2

    Get PDF
    Plots of all the hourly averages computed from the solar magnetic field measurements obtained during the mission are given separately for Helios 1 and Helios 2. The magnitude and the direction of the averaged field are plotted versus the number of solar rotations as seen from Helios, counted from launch

    Rhizopus microsporus var. rhizopodiformis: a thermotolerant fungus with potential for production of thermostable amylases

    Get PDF
    The effect of several nutritional and environmental parameters on growth and amylase production from Rhizopus microsporus var. rhizopodiformis was analysed. This fungus was isolated from soil of the Brazilian “cerrado” and produced high levels of amylolytic activity at 45°C in liquid medium supplemented with starch, sugar cane bagasse, oat meal or cassava flour. Glucose in the culture medium drastically repressed the amylolytic activity. The products of hydrolysis were analysed by thin layer chromatography, and glucose was detected as the main component. The amylolytic activity hydrolysed several substrates, such as amylopectin, amylase, glycogen, pullulan, starch, and maltose. Glucose was always the main end product detected by high-pressure liquid chromatography analysis. These results indicated that the amylolytic activity studied is a glucoamylase, but there were also low levels of α-amylase. As compared to other fungi, R. microsporus var. rhizopodiformis can be considered an efficient producer of thermostable amylases, using raw residues of low cost as substrates. This information is of technological value, considering the importance of amylases for industrial hydrolysis

    Concise Review: Cell Therapy for Critical Limb Ischemia: An Integrated Review of Preclinical and Clinical Studies

    Get PDF
    Critical limb ischemia (CLI), the most severe form of peripheral artery disease, is characterized by pain at rest and non-healing ulcers in the lower extremities. For patients with CLI, where the extent of atherosclerotic artery occlusion is too severe for surgical bypass or percutaneous interventions, limb amputation remains the only treatment option. Thus, cell-based therapy to restore perfusion and promote wound healing in patients with CLI is under intense investigation. Despite promising preclinical studies in animal models, transplantation of bone marrow (BM)-derived cell populations in patients with CLI has shown limited benefit preventing limb amputation. Early trials injected heterogenous mononuclear cells containing a low frequency of cells with pro-vascular regenerative functions. Most trials transferred autologous cells damaged by chronic disease that demonstrated poor survival in the ischemic environment and impaired function conferred by atherosclerotic or diabetic co-morbidities. Finally, recent preclinical studies suggest optimized blood vessel formation may require paracrine and/or structural contributions from multiple progenitor cell lineages, angiocrine-secretory myeloid cells derived from hematopoietic progenitor cells, tubule-forming endothelial cells generated by circulating or vessel-resident endothelial precursors, and vessel-stabilizing perivascular cells derived from mesenchymal stem cells. Understanding how stem cells co-ordinate the myriad of cells and signals required for stable revascularization remains the key to translating the potential of stem cells into curative therapies for CLI. Thus, combination delivery of multiple cell types within supportive bioengineered matricies may represent a new direction to improve cell therapy strategies for CLI. Stem Cells 2018;36:161–171

    Dynamic validation of the Planck/LFI thermal model

    Get PDF
    The Low Frequency Instrument (LFI) is an array of cryogenically cooled radiometers on board the Planck satellite, designed to measure the temperature and polarization anisotropies of the cosmic microwave backgrond (CMB) at 30, 44 and 70 GHz. The thermal requirements of the LFI, and in particular the stringent limits to acceptable thermal fluctuations in the 20 K focal plane, are a critical element to achieve the instrument scientific performance. Thermal tests were carried out as part of the on-ground calibration campaign at various stages of instrument integration. In this paper we describe the results and analysis of the tests on the LFI flight model (FM) performed at Thales Laboratories in Milan (Italy) during 2006, with the purpose of experimentally sampling the thermal transfer functions and consequently validating the numerical thermal model describing the dynamic response of the LFI focal plane. This model has been used extensively to assess the ability of LFI to achieve its scientific goals: its validation is therefore extremely important in the context of the Planck mission. Our analysis shows that the measured thermal properties of the instrument show a thermal damping level better than predicted, therefore further reducing the expected systematic effect induced in the LFI maps. We then propose an explanation of the increased damping in terms of non-ideal thermal contacts.Comment: Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-022
    corecore